D.     GAS CONNECTION: 

  The gas supply (service) line must be the same size or greater than the inlet line of the appliance.  

THE GAS

          SUPPLY LINES MUST BE SIZED TO ACCOMMODATE ALL THE GAS FIRED EQUIPMENT THAT MAY BE CONNECTED 
         TO THAT SUPPLY.  

Refer to the Inlet Gas Line Sizing Table and inlet gas requirements. 

         NOTE:

  Sealant used on all pipe joints must be resistive to butane and propane gas.

        1.     Manual shut off valve:  This supplier-installed valve must be installed in the gas service line ahead of the appliance and in a 
                position where it can be reached quickly in the event of an emergency.
        2.     Pressure regulator:  All commercial cooking equipment must have a pressure regulator on the incoming service line for safe 
                and efficient operation, because service pressure may fluctuate with local demand.  External regulators are not required on this 
                fryer, as that function is performed by a combination gas control valve, however if the incoming pressure is in excess of 1⁄2 psig, 
                a step-down regulator will be required. 
        3.     Natural gas:  Natural gas fryers require 7” (178mm) water column (W.C.) “inlet” pressure to the fryer’s combination gas con-
                trol valve for

 

proper operation, when all gas units are operating simultaneously.  Butane and Propane gas fryers require 14" 

                (356mm) water column (W.C.) “inlet” pressure to the fryer’s combination gas control valve for proper operation, when all gas
                units are operating simultaneously. This “inlet” pressure 

MUST

 be checked with a manometer 

PRIOR

 to placing the fryer in 

                operation.

WARNING:   IF THE “INLET” GAS PRESSURE AT THE FRYER’S COMBINATION GAS CONTROL VALVE “EXCEEDS”  1⁄2 lb/in2 

                           (.035 kg/cm2) OR APPROXIMATELY 14” (356 mm) W.C.,  AN EXTERNAL REGULATOR MAY BE NEEDED TO PRE-
                           VENT DAMAGE TO THE COMBINATION GAS VALVE,  AND VOIDING OF WARRANTY.  FAILURE TO ADDRESS
                           THIS COULD RESULT IN AN EXPLOSION OR A FIRE.

        4.     Combination gas control valve:  The correct combination gas control valve and orifice is installed at the factory for 

BUTANE, 

                  NATURAL 

and 

PROPANE

 units based on each Purchase Order.  This valve should be 

CHECKED/ADJUSTED

 by qualified 

                service personnel using proper test equipment for the following “

OUTLET

” gas pressure 

PRIOR

 to start-up of a fryer. 

NATU-

                  RAL GAS FRYERS 4" (102mm)  W.C. BUTANE/PROPANE FRYERS 10"  (254mm) W.C.

        5.     Rigid connections:  Check any installer-supplied intake pipe(s) visually and/or blow them out with compressed air to clear dirt 
                particles, threading chips or any other foreign matter before connecting to the service line as these particles may clog the  
                orifice when gas pressure is applied.  All connections must be tested with a soapy solution before lighting the fryer.  

DO NOT  

                  USE AN OPEN FLAME TO CHECK FOR LEAKS!

  Putting an open flame beside a new connection is not only dangerous, but 

                will often miss small leaks that a soapy solution would find.

        

6.   Flexible Couplings, Connectors:  The installation is to be made with a connector that (1) complies with the 

Standard for Con-

                nectors for

 

Movable Gas Appliances, ANSI Z21.69  (CAN/CGA-6.16)

, and a quick-disconnect device that complies with the 

              

Standard for Quick-Dis-connect Devices for Use With Gas Fuel, ANSI Z21.41 (CAN1-6.9)

 (2) adequate means must be pro-

              vided to limit the movement of the appliance without depending on the connector and the quick dis-connect device or its asso-
              ciated piping to limit the appliance movement and (3) the location(s) where the restraining means may be attached to the 
              appliance shall be specified. 

DOMESTIC CONNECTORS ARE NOT SUITABLE!!!

         

7.     Fryer Service:  The fryer is equipped with swivel casters.  To service the fryer:

                a)     Turn “OFF” gas supply at the supply source.
                b)     Disconnect the flexible gas line quick-disconnect
                c)     Disconnect restraint means and roll fryer out for rear service access.
                d)    When the fryer is re-positioned, be sure to reconnect the restraint and level the fryer.

E.     ELECTRICAL CONNECTION:

  The MAXIMUM current draw per vat at Initial Start-up or during a Warm-up Cycle will be 3 

        Amperes at 120 Volts.  When running the Filter System simultaneously allow for an additional 3 Amperes.  Refer to the wiring 
        diagram attached to the inside of the Service Access door for internal electrical connections.

Содержание F-P25-14

Страница 1: ...or other flammable vapors or liquids in the vicinity of this or other appliance WARNING Improper Installation adjustment alteration service or main tenance can cause property damage injury or death R...

Страница 2: ...ASSURE the male docking plug is SEATED in the female bulkhead socket CAUTION To assure producing a quality product while prolonging the life expectancy of the fryer ensure that the filtering boil out...

Страница 3: ...nts 10 PRE INSTALLATION General 12 Standards 12 Air Supply Ventilation 12 RECEIVING INSTALLING Unpacking 14 Installing 14 Leveling 14 Gas Connection 15 Electrical Connection 15 Cooking Computers 16 IN...

Страница 4: ...roubleshooting 24 Troubleshooting Chart 24 CLEANING 27 FILTER TUB ASSEMBLY INSTALLATION Filter Tub Assembly 29 Filter Tub Installation 29 TECHNICAL ASSISTANCE ORDERING INFORMATION Technical Assistance...

Страница 5: ...PN 30A169 rev Jan2008 5 GENERAL INFORMATION...

Страница 6: ...or on holidays the owner must call Ultrafryer Systems first at the above number This number is monitored 24 hours a day 7 days a week Ultrafryer Systems will notify an authorized service agent to make...

Страница 7: ...llows D ULTRAFRYER MODEL PAR3 PAR25 GAS FRYER DIMENSIONS OPERATIONAL REQUIREMENTS 14 VAT 18 VAT 20 VAT 24 VAT Overall Width 15 625 in 397 mm 19 625 in 498 mm 21 625 in 549 mm 25 625 in 651 mm Overall...

Страница 8: ...PN 30A169 rev Jan2008 8 MODEL PAR25 GAS FRYER E OPERATING CONTROLS LOCATION 1 Gas Regulator and Shutoff Valve 2 High Limit 3 Burner 4 Docking Connection 5 Main Drain Valve...

Страница 9: ...ning a solenoid actuated safety valve in the combination gas control valve 2 Combination gas control valve which includes a built in pressure regulator and manual valve 3 Sensing circuit within the sp...

Страница 10: ...1 176 4 9 360 10 1 630 17 6 1 000 28 0 2 050 57 4 600 182 9 10 0 3 27 0 8 56 1 6 97 2 7 152 4 3 315 8 8 530 14 8 860 24 1 1 750 49 0 NOTE 1 FT3 HR M3 HR values may vary due to heating value and specif...

Страница 11: ...PN 30A169 rev Jan2008 11 PRE INSTALLATION...

Страница 12: ...accordance with the current National Electrical code ANSI NFPA 70 latest edition In Canada electrical installation must be in accordance with the current CSA C22 1 Canadian Electrical Code and or loc...

Страница 13: ...PN 30A169 rev Jan2008 13 RECEIVING INSTALLING...

Страница 14: ...y not return exactly to the same position after being moved which may require re leveling after each move 3 Connect the gas manifold to the building gas supply line by means of a CSA International APP...

Страница 15: ...AL and PROPANE units based on each Purchase Order This valve should be CHECKED ADJUSTED by qualified service personnel using proper test equipment for the following OUTLET gas pressure PRIOR to start...

Страница 16: ...owing list shows the cooking computer types and their related manuals NOTE The appearance of a given cooking computer s control panel may vary slightly depending upon the style of fryer on which the c...

Страница 17: ...PN 30A169 rev Jan2008 17 Ultrastat 21 Cooking Computer refer to Manual P N 30A189 French Version 30A189 FR Ultrastat 11 Cooking Computer refer to Manual P N 30A191 French Version 30A191 FR...

Страница 18: ...PN 30A169 rev Jan2008 18 INITIAL START UP...

Страница 19: ...ING WARRANTY 3 Turn the manual gas valve located behind the fryer Service Access door to the OFF position and wait FIVE 5 minutes for any accumulated gas to disperse 4 ENSURE the MAIN gas shut off is...

Страница 20: ...PN 30A169 rev Jan2008 20 ABBREVIATED OPERATING INSTRUCTIONS...

Страница 21: ...0 FR C FILTERING SHORTENING 1 If the customer decides to use a shortening filtration system whether provided by Ultrafryer or from another source then the fryer must be filtered at least twice a day o...

Страница 22: ...OWER FAILURE a Shutdown Perform the following whenever a fryer is being shutdown for an extended period of time 1 Drain and discard the shortening 2 THOROUGHLY clean the fryer vat 3 Turn the ON OFF Sw...

Страница 23: ...PN 30A169 rev Jan2008 23 PREVENTIVE MAINTENANCE TROUBLESHOOTING...

Страница 24: ...spection must be performed periodically to prevent break downs which could curtail food sales Any preventive maintenance or inspection should be accomplished with CAUTION while the fryer is in operati...

Страница 25: ...E Check for damaged BLOWER fins F Use a standard water type U gauge Manometer to check the pres sure at the gas control valve pressure tap Proper gas pressure is indicated on the operational requireme...

Страница 26: ...PN 30A169 rev Jan2008 26 CLEANING...

Страница 27: ...NG SOLUTION OR WATER TO SPLASH INTO A VESSEL OF HOT COOKING OIL AS IT WILL CONTAMINATE THE OIL AND MAY CAUSE THE OIL TO SPLATTER CAUSING SEVERE BURNS 2 If a Filter Tub Assembly is used with this fryer...

Страница 28: ...PN 30A169 rev Jan2008 28 FILTER TUB ASSEMBLY INSTALLATION...

Страница 29: ...ub with the screen butted against the rear wall of the tub 3 Insert the Crumb Catcher Screen in the Filter Tub with the Drain Valve DOCKING FLANGE and MALE DOCKING PLUG over the leading edge of the pa...

Страница 30: ...PN 30A169 rev Jan2008 30 TECHNICAL ASSISTANCE ORDERING INFORMATION...

Страница 31: ...st be inspected for damage to shipping containers prior to departure of the delivering carrier Any damage must be documented on the receiving document to facilitate filing of freight claims Carriers m...

Страница 32: ...PN 30A169 rev Jan2008 32 RECOMMENDED SPARE PARTS...

Страница 33: ...ING Description Manufacturer s Part Number PN Ignitor Spark Module Honeywell S87B1008 18179 24 Volt Stepdown Transformer Honeywell AT40A1121 18180 24 Volt Combination Gas Control Valve Honeywell VR820...

Страница 34: ...PN 30A169 rev Jan2008 34 PARTS IDENTIFICATION...

Страница 35: ...26 4 Orifice see chart page 7 5 Ignitor Wire 18A095 6 Burner 22A341 7 Burner Bracket 19B505 8 Docking Release Handle for fryers with filter tub 19C177 9 Docking Connection 24A238 10 Micro Switch optio...

Страница 36: ...53 4 x 8 High 146 x 208mm Rectangular Flue Tube with deflector 19A910 7 125 Volt 75 Watt Silicon Heater 5 1524mm Long 23341 8 Gemini 1 2 13mm Pump Ball Valve 24 036 9 3 16 5mm ID 5 16 8mm OD Air Pres...

Страница 37: ...v Jan2008 37 ITEM DESCRIPTION PN 1 Electronic Thermostat Face Plate 18A070 2 Temperature Probe 18A276 3 Electronic P14 Thermostat Bracket 19B174 4 Electronic Thermostat Knob 22A169 ELECTRONIC THERMOST...

Страница 38: ...22479 10 Medium Duty Caster 28A005 NOT SHOWN ITEM DESCRIPTION PN 1 6 1829mm Wash Wand Hose w Fittings 12541 2 Wash Wand Hose Nozzle Assembly 12675 3 Proximity Sensor Actuator 18A059 4 Cool II Handle...

Страница 39: ...x 7 177 8mm Black Iron Nipple 24470 7 1 2 13mm S S Locking Seal Inline Plug 24A208 8 1 2 13mm Handle Assy With 90 Black Iron Elbow 19A598 11 x 18 1 4 279mm x 464mm Baffle Kit consists of items 9 10 11...

Страница 40: ...2 13mm S S Locking Seal Inline Plug 24A208 8 1 2 13mm x 6 152mm Black Iron Nipple 24A178 ULTRAFRYER MODEL PAR25 GAS FRYER AUTOMATIC VAT CLEANER 14 PN 12B157 ULTRAFRYER MODEL PAR25 GAS FRYER AUTOMATIC...

Страница 41: ...PN 30A169 rev Jan2008 41 WIRING DIAGRAMS...

Страница 42: ...PN 30A169 rev Jan2008 42 WIRING DIAGRAM Since minor wiring changes may occur in the future USE the diagram pasted to the fryer for circuit tracing and or troubleshooting a gas fryer...

Отзывы: