6
7
Fixings Identification
Lay out the DPC roll around the perimeter of the
base where walls are to be positioned, aligning
to the outside edge. Once walls and cills are in
place the excess can be trimmed away.
1
Installation
Reposition brackets over drilled holes. Fix the
bracket down to the slab using anchor fixings
provided (SLP005) ensuring you are fixing into
a substantial base.
4
Align steel angles to the edge of the column
and to the top of the column structural bracket
and secure to the column using NRTF050 (4.2
x 25mm wafer head screws) through the pre-
punched holes.
7
Evenly position cill on slab/base sealing any
joints with an appropriate sealant. Check level
and diagonals to ensure square and fix cill in
place to aid positioning.
2
Lift column into place and fix to the structural
bracket using fixings from SLP005 kit. Ensure
that the tall columns are positioned to the front
of the structure.
Repeat steps 3, 4 and 5 for each of the four
columns.
Fitters Tip:
Packers can be placed temporarily
on the cill under the column to alleviate column
wobble.
5
Measure back from the internal frame (this
datum is provided by the cill) by 189mm to the
inside face of the insulated column structural
bracket. Mark hole positions, remove bracket
and drill marked positions using a Ø10mm drill
bit.
3
Lift the walling panels into place starting at the
ends before filling in towards the middle.
9
Attach the column infill plate to the front column
on the faces adjacent to the garden room
projection. Aligning it with the top and internal
faces of the column timber. Fixing in place
using NRTF050 through the pre-cut holes.
8
Front
Apply sealant along the top surface of the cill
where walls are located. Position the walling
base trays centred between columns and
hard up against the cill. Check the tray is level
and fix down to slab using appropriate fixings
through the pre-punched holes in both internal
and external steels. Ensure the tray is level and
pulled down tight to the slab.
6