UltraCOOL CP70 Скачать руководство пользователя страница 5

5

 

 

 
For Fan Only Operation: 

With unit turned on: 

1.  Press the SPEED button and adjust as desired. 
2.  The FAN portion of the panel will show icons indicating the selected speed and 

the VENT icon will be illuminated in the center of the panel.  

Low Water Indication

1.  When the water tank has been depleted to a certain level, a LOW WATER 

indicator will display on the PUMP portion of the Control Panel. The COOL 
(snowflake) icon will go off, and the VENT (fan) icon will illuminate.  The pump 
will stop operating and an audible beeping will sound for 60 seconds or until 
the PUMP button is pressed. 

NOTE

: If refilled within 60 seconds of the beeping, the pump will restart 

automatically. 

2.  Otherwise, refill the tank and press the PUMP button to restart the pump. 

Additional Features: 

Oscillate Feature: 

1.  When the OSCILLATE button is pressed the vertical louvers on the front grill  

move left and right. 

2.  The OSCILLATE portion of the display will indicate activation of this feature. 
3.  Press again to turn feature off. This feature is available anytime the FAN 

function is turned on. 

Timer Feature

This unit has a timer feature that allows setting the duration of operation from half an 
hour to 8 hours, in 0.5 hour increments. When the set time is on the last half hour, 
the time will count down in tenths until it reaches 0.0 and turns off completely. 

1.  To set the timer, press TIMER and keep pressing until the desired amount is 

displayed in the TIMER section of the display.   

2.  Once the desired time is displayed, release the button. After 5 seconds the 

time is confirmed. 

3.  To cancel (after confirmation) press the TIMER button again.   

NOTE

: If continuous operation is desired Press TIMER and set at 0.0. The fan will 

run continuously. The pump will not operate if there is no water in the unit. 

 

 

 

 

Содержание CP70

Страница 1: ...vaporative cooling is an economical way to cool and is highly effective in arid climates Air is cooled while being drawn across wet evaporative media The movement of this fresh cooled air over the skin is what makes it feel cool In order for evaporative coolers to be effective in an enclosed area a fresh air source and adequate exhaust need to be present These coolers will not work well without an...

Страница 2: ...nd or repair 6 Do Not run cord under carpeting Do Not cover cord with throw rugs runners or similar coverings Do Not route cord under furniture or appliances Arrange cord away from traffic area and where it will not be tripped over WARNING To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device Assembly For shipping purposes the base and caste...

Страница 3: ...ur screws provided to attach the base to the body of unit Set upright Fill with Water The reservoir on this unit holds 6 gallons 1 To fill the reservoir open the water fill door at the front and fill with fresh clean water using a fill hose or pitcher DO NOT OVERFILL CAUTION If moving the unit for filling make sure the casters are unlocked for easy mobility Do not tip unit 2 A fill indicator to th...

Страница 4: ...r If no evaporative cooling is desired simply do not engage the pump and use only the fan feature For Evaporative Cooling With the unit already turned on 1 Press the PUMP button This will activate the pump to begin saturating the media 2 Press the SPEED button to engage the fan The 3 speed fan starts in High and can be adjusted down by pressing the SPEED button again 3 During this function the FAN...

Страница 5: ... 1 When the OSCILLATE button is pressed the vertical louvers on the front grill move left and right 2 The OSCILLATE portion of the display will indicate activation of this feature 3 Press again to turn feature off This feature is available anytime the FAN function is turned on Timer Feature This unit has a timer feature that allows setting the duration of operation from half an hour to 8 hours in ...

Страница 6: ...media pad try to preserve the integrity of the fluted surface 4 Reinstall drain cap and refill with fresh water Plug in and operate per instructions Regular Servicing Accomplish at least twice a season more often in areas with hard water 1 Remove back section see Step 1 under Assembly 2 Using water hose wash out back with fresh water Clean media pad DO NOT use chemicals or pressure washer on media...

Страница 7: ...drained of water 2 Carefully inspect media to verify media is not crushed broken and clogged or heavily encrusted with minerals If so dispose and replace media pad 3 Clean interior with clean water Wipe down outside with clean damp cloth 4 Store in safe dry place Do not store with water in reservoir Trouble shooting PROBLEM PROBABLE CAUSE REMEDY Pump is not working Unit may be out of water Pump ma...

Страница 8: ...s set of 4 110871 6 Pump 110439 4 7 Drain cap 110698 2 8 Float assembly 110873 9 Swivel casters Non locking 110822 6 10 Swivel casters Locking 110822 7 11 Pedestal 110874 2 12 Water distributor tubing 110734 1 13 M3 5 x 12mm Truss Head SS Screws Qty 2 111130 14 M4 x12mm Truss Head SS Screw Qty 4 111131 To purchase parts call 1 800 643 8341 or visit championcooler com 8 5 5 1 9 10 9 10 6 7 11 2 12 ...

Страница 9: ...ponsible for any incidental or consequential damage resulting from any malfunction We are not responsible for any damage received from the use of water softeners chemicals de scale material or plastic wrap We are not responsible for the cost of service calls to diagnose the cause of trouble or labor charge to repair and or replace parts How to Obtain Service Under this Warranty Contact the Dealer ...

Страница 10: ...10 Intentionally left blank ...

Страница 11: ...o por evaporación es una forma económica de enfriar y es muy efectivo en climas áridos El aire se enfría mientras ingresa en medios de evaporación húmedos El movimiento de este aire fresco enfriado hacia la piel es lo que lo hace a usted sentirse fresco Para que los enfriadores por evaporación sean efectivos en un área cerrada es necesario tener una fuente de aire fresco y un escape adecuado Estos...

Страница 12: ...ombra No cubra el cable con alfombras correderas o protectores similares No guíe el cable debajo de muebles o equipos Coloque el cable lejos de áreas transitadas donde nadie pueda tropezarse PRECAUCIÓN Para reducir el riesgo de incendios o de descarga eléctrica no use este ventilador con ningún dispositivo de control de velocidad de ventilador en estado sólido Montaje Por motivos de envío la base ...

Страница 13: ...o de la unidad Enderécelo Llénelo con agua El depósito en esta unidad tiene una capacidad de 6 galones 1 Para llenar el depósito abra la puerta de llenado de agua en la parte frontal y llénelo con agua fresca y limpia usando una manguera o una jarra NO LLENE EN EXCESO ADVERTENCIA Si se mueve la unidad para su llenado asegúrese de que las ruedas estén desbloqueadas para mover con facilidad No incli...

Страница 14: ...miento evaporativo simplemente no accionar la bomba y solo use la función de ventilador Para enfriamiento por evaporación Con la unidad ya encendida 1 Presione el botón PUMP bomba Esto activará la bomba para que comience la saturación del medio 2 Presione el botón SPEED velocidad para activar el ventilador El ventilador de 3 velocidades comenzará en la velocidad Alta y se podrá disminuir al presio...

Страница 15: ...e OSCILLATE oscilación las persianas verticales en la rejilla frontal se moverán a la izquierda y a la derecha 2 La sección de OSCILLATE oscilación de la pantalla indicará la activación de esta función 3 Presiónelo nuevamente para desactivar la función Esta función está disponible en cualquier momento en que se encienda la función de ventilador Función de temporizador Esta unidad tiene una función...

Страница 16: ...la entereza de la superficie acanalada 4 Vuelva a instalar la tapa de drenaje y rellene el tanque con agua fresca Enchúfelo y contrólelo según las instrucciones Mantenimiento estándar Llevar a cabo al menos dos veces por estación más frecuente en áreas con agua dura 1 Retire la sección trasera consulte el Paso 1 en Montaje 2 Con la manguera de agua lave la parte trasera con agua dulce Limpie la al...

Страница 17: ...medio cuidadosamente para verificar que no esté aplastado roto y obstruido o demasiado incrustado de minerales De ser así deseche y reemplace la almohadilla del medio 3 Limpie el interior con agua limpia Limpie el exterior con un paño húmedo limpio 4 Almacene en un lugar seco y seguro No guarde la unidad con agua en el depósito Solución de problemas PROBLEMA CAUSA PROBABLE SOLUCIÓN La bomba no fun...

Страница 18: ...omba 110439 4 7 Tapa de drenaje 110698 2 8 Montaje del flotador 110873 9 Ruedas giratorias sin fijación 110822 6 10 Ruedas giratorias con fijación 110822 7 11 Pedestal 110874 2 12 Tubería del distribuidor de agua 110734 1 13 Tornillos de cabeza segmental acero inoxidable M3 5 x 12mm Cantidad 2 111130 14 Tornillos de acero inoxidable Phillips M4 x12mm Cantidad 4 111131 Para comprar repuestos llame ...

Страница 19: ...ningún daño incidental o consecuente resultante de cualquier mal funcionamiento No somos responsables por ningún daño recibido por el uso de suavizantes de agua químicos materiales de desincrustación o envolturas plásticas No somos responsables por el costo de las llamadas de servicio para diagnosticar el problema o costos de mano de obra para reparar o reemplazar repuestos Cómo obtener servicio b...

Страница 20: ...20 A Division of Champion Cooler 5800 Murray St Little Rock AR 72209 ...