background image

6

Do not smoke while operating, sitting or resting in the chair.

To reduce risk of electrical shock, do not immerse any of the 

electrical components into a liquid, or spill any liquids onto electrical 

components. Do not open any of the electrical components. There are 

no serviceable parts.
Warranty will be void if any of the electrical components are opened by 

other than a qualified service person.
Make sure the chair is placed at the specified distance from a wall/

corner (page 8). Failure to do so can damage the chair and will void 

the warranty.

Do not use any type of electrical extension cord to plug your 

chair into an electrical outlet. Make sure that all electrical 

products and their wires are positioned away from your chair 

as the metal lift frame mechanism could crush them and 

create a fire hazard and/or may cause personal injury.

Do not operate your lift chair while intoxicated or taking medications 

that impair your mental or physical abilities to operate the chair safely. 

Consult with your doctor about any medications you are taking that 

may affect the safe operation of the chair.
Do not operate this product if you have any medical conditions that 

result in limited, debilitating mental or physical capacity. You should 

consult your doctor before using this product.
Consult with your physician regarding using the Trendelenburg 

position.

Placing the lift chair in the center of a room or too far away from a wall 

will create a tripping hazard, because the power wires for the lift chair 

will be crossing main traffic areas in the residence.

If the lift chair user is unconscious or sleeping the hand control may 

inadvertently become activated in a way that may force the user out of 

the chair.
Should you ever encounter a problem with the operation of your power 

lift chair, discontinue all use of the product upon discovery of the 

problem. Contact the provider from whom you purchased your chair 

to arrange service.

Exceeding the stated weight limit listed in this manual can result in 

instability of the lift chair, causing a potential tip over hazard.

Consult the owner’s manual of the chair and a physician to determine if 

you are capable of moving or lifting the chair, as this will cause serious 

injury if not done properly.

Содержание UC562

Страница 1: ...R S MANUAL AND LIMITED LIFETIME WARRANTY UC562 UC570 UC490 UC799 ECLIPSE TECHNOLOGY MSWARB UC562 UC570 UC490 UC799 041421 UC562 MLA Medium Large Power Lift and Recline 401 Bridge Street Old Forge Pa 1...

Страница 2: ...ble use of your UltraComfort chair and that this chair becomes a true assist to you in both sitting down and standing up Please take a few moments to review this manual to become familiar with the ope...

Страница 3: ...ite symbol on a blue dot with a white border PROHIBITED Indicate s an action s that should not be performed under any circumstance Failure to adhere could cause personal injury and or equipment damage...

Страница 4: ...4 continued from previous page Safety Guidelines Class II Device Indoor use only Do Not Smoke Electrical hazard Do not dispose in trash...

Страница 5: ...hair is not in use Do not flop down into the chair when getting into it or while it is in its lift position Flopping down into the chair will damage it and could cause personal injury Do not allow any...

Страница 6: ...medications you are taking that may affect the safe operation of the chair Do not operate this product if you have any medical conditions that result in limited debilitating mental or physical capaci...

Страница 7: ...jury This is an electrical device and will be impacted by any power failure To operate this chair properly you must read and understand the intended use of the product and overall operation of the cha...

Страница 8: ...room where it will be most convenient for you such as near the television radio reading light end table or other furniture Leave enough space between back of chair and wall or other obstruction to al...

Страница 9: ...epeat no 1 when you want to sit down 3 To move the cradle out away from wall up and out Press S10 and hold it until the chair reaches a position suitable for you then release the button 4 To move the...

Страница 10: ...button is pressed 2 In about 4 seconds the backlight will start flashing 3 Within 5 seconds press button S1 The backlight will change to non flashing 4 Within another 5 seconds press button S4 Factor...

Страница 11: ...elease the button when the chair reaches the desired height 8 To recline your chair from the lift position press the down button S2 and hold The chair will keep going past the seated position and star...

Страница 12: ...ne flash 3 Within 5 seconds press one of the memory buttons M1 M2 to save the position to the button pressed The back light will return to non flashing position indicating that the new position is sto...

Страница 13: ...1 when you want to sit down Micro Adjustments 1 To recline the back of the chair press button S1 and hold until the back reaches the desired position Then release the button 2 To bring the back of th...

Страница 14: ...n Initial Hand Control Setup This setup is required to ensure proper operation of your lift chair s control system ZK3100 C5M UC Setup Reset Procedure Press and hold all three buttons S1 Backrest down...

Страница 15: ...The back light goes off while pressed 1 In about 3 seconds the backlight will start flashing one flash 2 Within 5 seconds press one of the memory buttons S5 S6 S8 S10 to save the position to the butt...

Страница 16: ...n use the function lock feature to disable all button function except for buttons S7 and S9 1 To lock function press and hold the program button SP for 4 seconds until the backlight starts flashing 2...

Страница 17: ...the system Spilled liquid may damage the system Do not reach for any portion of the system that has fallen into water or any other liquid Unplug immediately Contact provider for service Use the power...

Страница 18: ...plugged see installation on page 8 for electrical connections Should you ever encounter a problem with the operation of your power lift chair and the lights are on such as mechanical problems or one l...

Страница 19: ...19 Patented Eclipse Positioning Technology TM Lounge Reclined TV in Eclipse Up TV Lounge Zero Gravity Trendelenburg Rejuvenate Chair arm removed for demonstration purposes not available on the UC490...

Страница 20: ...ary service calls i e service calls solely for the purpose of educating the consumer about the product or finding an unsatisfactory power connection etc Exceeding the weight capacity of the chair publ...

Страница 21: ...e cleaning your lift chair consult your provider for the proper types of cleaner and cleaning methods 9 Keep all electrical components free from moisture and liquid spills Intended for indoor use only...

Страница 22: ...22 Notes...

Страница 23: ...23 Notes...

Страница 24: ...24 Notes...

Страница 25: ...Comfort That s Patented AMERICA UltraComfort 401 BRIDGE ST OLD FORGE PA 18518 2323 PLACE STAMP HERE...

Страница 26: ......

Страница 27: ...__________________________________________ Your Ultra Comfort representative or provider Name _____________________________________________________________ Company ____________________________________...

Страница 28: ...underneath chair and from in front of footrest while operating chair Do not allow children to play on this mechanized furniture or operate the mechanism Leg rest folds down on closing so that a child...

Отзывы: