Set up the charge current on the left and
nominal voltage on the right. Range of current
the voltage should match the battery being
charged. Press START/ENTER button for
more than 3 seconds to start charging.
The screen display the real-time charging
status. Press START/ENTER button again
to store the parameter value you set. Press
BATT TYPE/STOP button to end the
program.
Set up the discharge current on the left and
nominal voltage on the right. Range of
discharge current is 0.1-5.0A(CH1,CH2),
0.1-2.0A(CH3,CH4), the voltage should match
the battery being discharged. Press
ENTER/START button for more than 3
seconds to start discharging.
This program is only suitable for charging Pb lead-acid battery with
nominal voltage from 2 to 20V, Pb lead-acid battery is a completely
different from NiMH/NiCD battery. These batteries can only deliver
current lower in comparison to their capacity. The same restriction
applies to the charging process consquently, the optimum charge
current can only be 1/10 of the capacity. Pb battery can not be used
for fast-charging. Please follow the instructions provided by the
battery manufacturer.
CHARGING OF PB BATTERY
DISCHARGING OF PB BATTERY
Start
Enter
Batt type
Stop
>3 seconds
DEC. INC.
DEC. INC.
Start
Enter
Batt type
Stop
>3 seconds
DEC. INC.
DEC. INC.
Battery
type
-
Elapsed
time
+
Charge
current
Battery
voltage
- +
Charged
capacity
- +
- +
PB BATTERY PROGRAM
18