MAINTENANCE ANd STORAGE
Generator Maintenance
Make certain that the generator is kept clean and stored
properly . Only operate the unit on a flat, level surface in
a clean, dry operating environment . DO NOT expose the
unit to extreme conditions, excessive dust, dirt, moisture
or corrosive vapors .
Storage
The generator should be started at least once every 14
days and allowed to run for at least 20 minutes . For
longer term storage, please follow these guidelines .
Generator Storage
1 . Allow the engine to cool completely before storage .
2 . Clean the generator according to the instructions in
the Maintenance section .
3 . Turn the Fuel Valve to the “OFF” position .
4 . Be sure all appliances are disconnected from the
generator . Start the engine and let it run until the
fuel in the line and the carburator is consumed and
the engine dies .
5 . Add a fuel stabilizer into the fuel tank .
6 . Change the oil .
7 . Remove the spark plug and pour about ½ ounce
of oil into the cylinder . Crank the engine slowly to
distribute the oil and lubricate the cylinder .
8 . Reattach the spark plug .
9 . Store the unit in a clean, dry place out of direct
sunlight .
Use a damp cloth to clean exterior surfaces of the generator .
Use a soft bristle brush to remove dirt and oil .
Use an air compressor (25 PSI) to clear dirt and debris
from the generator .
Inspect all air vents and cooling slots to ensure that they
are clean and unobstructed .
DO NOT use a garden hose to clean the generator .
Water can enter the generator through the cooling
slots and damage the generator windings .
CAUTION
Generator exhaust contains odorless and colorless
carbon monoxide gas .
To avoid accidental or unintended ignition of your
generator during periods of storage, the following
precautions should be followed:
– When
storing the generator for short or extended
periods of time make sure that the Engine
Switch and the Fuel Valve are set in the
OFF
position .
dANGER