HyperSpike
®
HS-18 RAHD Operation and Maintenance Manual
Copyright © Ultra Electronics USSI Columbia City, IN 46725 USA
90207A-MAN-HS18RAHD
REV C
8
To wire your HS-18 RAHD for operation, refer to the following wiring instructions:
3.2.1. Connection #1: Interconnect Cable
Connect the Interconnect Cable, P/N 42206A-801, from connector C to connector E.
This cable passes data and AC power to the
Emitter’s electronics housing. Tighten each
end of the cable firmly to ensure a weather-tight seal.
3.2.2. Connection #2: Power/Data Cable
Connect the Power/Data Cable, P/N 42222A-801, to connector F. Tighten the cable
firmly to ensure a weather-tight seal.
While the HS-18 RAHD is designed for direct operation on a 20 Amp, 110 VAC circuit, a
step-down transformer is available for locations that have only 220 VAC. An isolation
transformer is also available for locations with non-standard or unreliable AC power.
Follow the wiring diagrams below to properly wire your HS-18
RAHD’s Power/Data
Cable.
Figure 8: Wiring Diagram for 110 VAC
– No Transformer and Hole Size
Wiring Color Chart - Power/Data Cable P/N 42222A-801
Brown
110 VAC Hot
Orange
110 VAC Hot
Gray
110 VAC Neutral
Green
110 VAC Neutral
Black
Ground
Red
Ground
White
Ground
Blue
Ground
Ethernet Cable
Network