WARRANTY

Limited Warranty.

 Therma-Stor, LLC (“Therma-Stor”) warrants as follows: (i) the Ultra-Aire XT205H dehumidifier (“Product”) 

will be free of material defects in workmanship or materials for a period of one (1) year (“One-Year Warranty”) following the date 
of initial purchase of such Product by an original customer purchasing from Therma-Stor or an authorized reseller (“Customer”); 
and (ii) the Product’s condenser, evaporator, and compressor will be free of material defects in workmanship or materials for a 
period of five (5) years following the date of initial purchase of such Product by a Customer. 

Limitation of Remedies.

 CUSTOMER’S SOLE AND EXCLUSIVE REMEDY UNDER THE ABOVE LIMITED WARRANTY AND 

THERMA- STOR’S ENTIRE LIABILITY THEREUNDER, SHALL BE, AT THE SOLE OPTION OF THERMA-STOR, REPLACEMENT 
OR REPAIR OF SUCH PRODUCT OR ITS COMPONENTS (“COMPONENTS”) BY THERMA-STOR OR THERMA-STOR’S 
AGENTS ONLY. REFRIGERANT, PIPING, SUPPLIES, TRANSPORTATION COSTS, LABOR COSTS INCURRED IN REPAIR OR 
REPLACEMENT OF SUCH COMPONENTS ARE NOT INCLUDED. THIS DISCLAIMER AND EXCLUSION SHALL APPLY EVEN 
IF THE EXPRESS WARRANTY AND LIMITED REMEDY SET FORTH HEREIN FAILS OF ITS ESSENTIAL PURPOSE. CUSTOMER 
ACKNOWLEDGES THAT NO REPRESENTATIVE OF THERMA-STOR OR OF ITS AFFILIATES OR RESELLERS IS AUTHORIZED 
TO MAKE ANY REPRESENTATION OR WARRANTY ON BEHALF OF THERMA-STOR OR ANY OF ITS AFFILIATES OR 
RESELLERS THAT IS NOT IN THIS AGREEMENT. Notwithstanding the above, during the term of the One-Year Warranty only, 
Therma-Stor will provide, free of charge to Customer, all Components and labor (except costs related to removal and installation 
of Product) required to fulfill its obligations under such One-Year Warranty. 

Disclaimer of Warranties.

 EXCEPT FOR ABOVE LIMITED WARRANTY, WHICH IS THE SOLE AND EXCLUSIVE 

WARRANTY PROVIDED WITH RESPECT TO THE PRODUCT AND ITS COMPONENTS, THERMA-STOR HEREBY DISCLAIMS 
ALL EXPRESS AND IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF 
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. 

Warranty Limitations.

 The foregoing limited warranty extends only to a Customer and shall be null and void upon attempted 

assignment or transfer. A “defect” under the terms of the limited warranty shall not include problems resulting from Customer’s 
or Customer’s employees’, agents’, invitees’ or a third party’s misuse, improper installation, improper design of any system 
in which the Product is included, abuse, lack of normal care, failure to follow written instructions, tampering, improper repair, 
or freezing, corrosion, acts of nature or other causes not arising out of defects in Therma-Stor’s workmanship or material. If a 
Product or Component is replaced while under warranty, the applicable limited warranty period shall not be extended beyond 
the original warranty time period. The limited warranty does not cover any costs related to changes to a Product or Component 
that may be required by any codes, laws, or regulations that may become effective after initial purchase of the Product by 
Customer. 

Customer Responsibilities.

 As a further condition to obtaining warranty coverage hereunder, the Customer must send a 

valid warranty claim to Therma-Stor such that Therma-Stor receives such claim prior to the end of the applicable warranty 
period. Therma-Stor shall have no obligation hereunder with respect to any claim received by Therma-Stor after the expiration 
of the applicable warranty period. As a further condition to obtaining warranty coverage hereunder, the Customer must present 
forms of invoices evidencing proof of purchase of a Product. If such invoices do not clearly indicate the date of initial purchase 
by a Customer, the applicable Product’s date of manufacture will be used instead of the date of initial purchase for the 
purpose of calculating the commencement of the applicable warranty period. Warranty service must be performed by Therma-
Stor or a servicer authorized by Therma-Stor. In order to obtain warranty service, the Customer should call Therma-Stor at 
1-800-533-7533 and ask for the Therma-Stor Products Service Department, which will then arrange for applicable warranty 
service. Warranty service will be performed during customary, daytime working hours. If the Product must be shipped for 
service, Customer shall be solely responsible for properly packaging the Product, for all freight charges, and for all risk of loss 
associated with shipment. 

Limitation of Liability.

 IN NO EVENT SHALL THERMA-STOR, IN CONNECTION WITH THE DESIGN, SALE, INSTALLATION, 

USE, REPAIR, REPLACEMENT OR PERFORMANCE OF ANY PRODUCT, COMPONENT, PART THEREOF OR WRITTEN 
MATERIAL PROVIDED THEREWITH, BE LIABLE, TO THE EXTENT ALLOWED UNDER APPLICABLE LAW, UNDER ANY 
LEGAL THEORY FOR ANY SPECIAL, DIRECT, INDIRECT, COLLATERAL OR CONSEQUENTIAL DAMAGES OF ANY KIND. 
NOTWITHSTANDING THE ABOVE LIMITATIONS AND WARRANTIES, THE SOLE AND EXCLUSIVE LIABILITY OF THERMA-
STOR, REGARDLESS OF THE NATURE OR THEORY OF THE CLAIM, SHALL UNDER NO CIRCUMSTANCES EXCEED THE 
PURCHASE PRICE OF THE PRODUCT, COMPONENT OR PART UPON WHICH THE CLAIM IS PREMISED. 

Applicable Law and Venue.

 ANY ARBITRATION, ENFORCEMENT OF AN ARBITRATION OR LITIGATION RELATED TO 

THE PRODUCT WILL BE BROUGHT EXCLUSIVELY IN DANE COUNTY, WISCONSIN, AND CUSTOMER CONSENTS TO THE 
JURISDICTION OF THE FEDERAL AND STATE COURTS LOCATED THEREIN, SUBMITS TO THE JURISDICTION THEREOF 
AND WAIVES THE RIGHT TO CHANGE VENUE. CUSTOMER FURTHER CONSENTS TO THE EXERCISE OF PERSONAL 
JURISDICTION BY ANY SUCH COURT WITH RESPECT TO ANY SUCH PROCEEDING. 

Miscellaneous.

 If any term or condition of this Limited Warranty is found by a court of competent jurisdiction to be invalid, 

illegal or otherwise unenforceable, the same shall not affect the other terms or conditions hereof or thereof or the whole of this 
Limited Warranty. Any delay or failure by Therma-Stor to exercise any right or remedy will not constitute a waiver of Therma-
Stor to thereafter enforce such rights.

Содержание XT205H

Страница 1: ...imate in comfort health and property protection through Dehumidification Fresh Air Ventilation Optional Air Filtration TS 903 3 24 16 P N 4031560 Serial No Install Date Sold by HVAC Installer Please Leave Manual for Homeowner PATENTS D570 988 8 069 681 9 052 132 Installation Instructions INSTALLATION BY A HVAC PROFESSIONAL IS RECOMMENDED ...

Страница 2: ... 11 Alternative HVAC System Installations 12 Recommended Multiple HVAC Systems Installation 13 No Existing Ductwork Installation 14 Fresh Air Ventilation 15 Determine Ventilation Requirements 16 Controls 17 Air Filtration 19 MERV Rating Chart 20 Service 21 Troubleshooting 22 Warranty 24 TABLE OF CONTENTS Ultra Aire is committed to manufacturing quality products To maintain our standards product sp...

Страница 3: ...TALLATION MAY CAUSE PROPERTY DAMAGE OR INJURY INSTALLATION SERVICE AND MAINTENANCE MUST BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN DEHUMIDIFIER IS HEAVY HANDLE WITH CARE AND FOLLOW INSTALLATION INSTRUCTIONS DO NOT USE IN POOL APPLICATIONS OR WARRANTY WILL BE VOID NEVER OPERATE A UNIT WITH A DAMAGED POWER CORD IF THE POWER CORD IS DAMAGED IT MUST BE REPLACED BY THE MANUFACTURER ITS SERVICE AGEN...

Страница 4: ...0 Pints kWh Duct Connections 6 Round Inlet 10 Round Inlet 10 Oval Outlet Air Filter MERV 11 Standard Pleat Efficiency 65 ASHRAE Dust Spot Size 16 x 20 x 2 Optional Air Filter MERV 14 Embossed Pleat will need filter housing Efficiency 95 ASHRAE Dust Spot Size 20 x 24 x 4 Power Cord 9 115VAC Ground Internal Insulated Cabinet Yes Drain Connection 3 4 Threaded Female NPT Refrigerant Type R410A Refer t...

Страница 5: ... Flex Duct 25 4022126 10 Flex Insulated Duct 25 4028399 10 Oval to Round Adapter Items Included in Box Ultra Aire XT205H Dehumidifier Ultra Aire XT205H Installation Instructions Ultra Aire XT205H Leveling Feet Removal of Compressor Shipping Support The Ultra Aire XT205H uses a compressor to power the refrigeration system To protect the compressor and refrigeration system during shipping a plastic ...

Страница 6: ...uire the removal of a side panel Allow sufficient clearance on a side of the unit Locate the dehumidifier in an area where the cord s length 9 easily reaches a 115 VAC electrical outlet with a minimum of a 20 Amp circuit capacity Locate the dehumidifier in an area where field wiring the control low voltage to the unit will be possible It is recommended that a backdraft damper be used in the discha...

Страница 7: ...r duct to the unit using the screws provided The 6 duct should be capped if fresh air is not desired If setting up the unit to provide fresh air ventilation see page 17 Return Air Inlet Attach 10 diameter duct collar to the unit with the screws provided Supply Air Outlet Adhere seal onto the back of the oval duct and mount the duct to the front of the dehumidifier using the screws provided Collars...

Страница 8: ...ITCH XFMR RED 1 WHT 4 GRN 5 BLU 7 BLU 8 VIO 8 PNK 3 GRN 10 BLU 9 BLK BLK BLK 1 GRN 4 YEL 6 B R N 3 RUN CAP RUN CAP 4032241 ELECTRICAL REQUIREMENTS CAUTION DO NOT ALLOW THE YELLOW LEAD TO CONTACT THE RED OR WHITE LEAD ON THE ULTRA AIRE XT205H OR DAMAGE TO THE TRANSFORMER WILL RESULT Electrical Precautions Do not install the control where it may not accurately sense the relative humidity such as nea...

Страница 9: ...s automatically pumped to a remote location when the water level in the pump s reservoir rises to close the float switch The pump also contains a safety float switch The white leads from this switch extend from beneath the pump cover This switch should be installed in series with the field wire that connects to the common lead from the Ultra Aire XT205H to the control panel If the pump fails this ...

Страница 10: ...d to reduce noise and vibration transmitted to rigid ductwork in the structure Use a minimum 10 diameter round or equivalent rectangular duct for total duct lengths of up to 25 Use a minimum 12 diameter round or equivalent rectangular duct for longer lengths Grills or diffusers on the duct ends must not excessively restrict airflow A length of 10 or more of insulated flex duct or any other vibrati...

Страница 11: ...ly of the existing HVAC system with a backdraft damper If the existing system has multiple returns instead of installing a dedicated return to the Ultra Aire XT205H it is possible to select one to disconnect from the existing HVAC system and use it for the dedicated Ultra Aire XT205H return Select a return from a central location in the house that is always open to the rest of the structure DO NOT...

Страница 12: ...n on when the dehumidifier is in operation Create a separate return for the Ultra Aire XT205H in a central area of the building Installing the supply air from the Ultra Aire XT205H to the return of the HVAC system requires the HVAC fan to run when the Ultra Aire XT205H is operating Check Damper should be in place between the Return and Supply connections of the dehumidifier If Check Damper is not ...

Страница 13: ...central location HVAC systems should be in close proximity for optimal air flow For multiple systems contact Technical Support at 1 800 533 7533 DUCTING TO HVAC SYSTEMS Recommended Multiple HVAC Systems Installation First Air Handler HVAC Return HVAC Supply Second Air Handler HVAC Supply Dedicated Ultra Aire 205 Return to Multi systems HVAC Return Fresh Air Intake Optional Motorized Damper Indoor ...

Страница 14: ...n etc Be sure to utilize multiple rooms to allow air inside the structure to properly circulate Proper air distribution is important to ensure even humidity control and heat distribution throughout the structure A 6 diameter duct is recommended for branches to bedrooms An 8 diameter duct is recommended for branches to larger areas DO NOT locate the return in a bathroom or kitchen DO NOT locate the...

Страница 15: ...torized damper is used a digital control is required It may be necessary to use 8 duct work if additional fresh air is required In cold climates or at times when the dew point is low ventilation can be used to dehumidify the structure making the Ultra Aire XT205H capable of year round drying FRESH AIR VENTILATION Hot Climate 6 Fresh Air Inlet Optional 10 Return Air Inlet 10 Supply Air Outlet A B C...

Страница 16: ... CFM ____________ FRESH AIR VENTILATION Determine Ventilation Requirements The MINIMUM ventilation requirement is calculated using ASHRAE 62 2 2010 Use one or both of the options below to determine your ventilation requirement Follow all local and national building and safety codes Table 4 1 from ASHRAE 62 2 2010 Floor Area ft2 1500 ft2 1501 3000 3001 4500 4501 6000 6001 7500 7500 ft2 0 1 30 45 60...

Страница 17: ...THE TRANSFORMER WILL RESULT Control Connections The control and the control wires leaving the Ultra Aire XT205H are numbered and color coded to prevent confusion Depending on the control some of the wires leaving the Ultra Aire XT205H may not be used For safety the unconnected wires should be covered with wire nuts Be sure to consult the electrical schematic in this manual or inside the access pan...

Страница 18: ...power transformer neutral side common with red Yellow Transformer high side Five Color Coded Wires Control Operation Unit ON Fan ON Make contact between yellow and blue wires Unit OFF Fan On Make contact between yellow and green or brown wires Power HVAC Accessory Connect the accessory to the white or red wire and the yellow wire Between the red white lead and the yellow lead is a 40VA transformer...

Страница 19: ...1 Release the latch from the cabinet by pulling it down and out Remove the filter door by pulling it out of the bottom tab Step 2 Remove the filter by gently pulling it straight out of the unit Insert new filter by gently pushing it straight into the unit Make sure the AIR FLOW arrow on the filter is pointing into the unit Step 3 Insert filter door into bottom tab Push latch down and swing door sh...

Страница 20: ...al Bag Filter Nonsupported Legionella microfine fiberglass or 11 60 65 95 Humidifier Dust Better Commercial Buildings synthetic media 12 36 in deep 6 12 pockets Lead Dust 10 50 55 95 Milled Flour Box Filter Rigid Style Cartridge Filters 6 to 12 deep may use lofted or paper media Auto Emissions Hospital Laboratories 9 40 45 90 Welding Fumes 8 30 35 90 3 0 10 0 pm Particle Size Commercial Buildings ...

Страница 21: ...s left in the system it must be recovered before weighing in the new charge Refer to the unit nameplate for the correct charge weight and refrigerant type SERVICE Service Parts List Item Part No Description 1 4021475 Air Filter 16 x20 x2 MERV 11 2 4026221 Foot Leveling 5 16 18 3 4031085 02 Condenser Coil 4 4031086 05 E coat Evaporator Coil 5 4029510 Filter Drier 6 4032229 Thermostat Defrost Contro...

Страница 22: ...wires together only the fan should run Disconnect the wires 8 Connect the yellow and blue wires together fan and compressor should run Disconnect the wires 9 If this test works then the field control wiring is ok 10 If the problem persists then the control is most likely faulty WARNING ELECTRICAL SHOCK HAZARD ELECTRICAL POWER MUST BE PRESENT TO PERFORM SOME TESTS THESE TESTS SHOULD BE PERFORMED BY...

Страница 23: ...egrees or below and or in area of low relative humidity the dehumidifier will produce little to no water 7 Collecting the water removed in a 24 hour period will give a measurement of performance WARNING ELECTRICAL SHOCK HAZARD ELECTRICAL POWER MUST BE PRESENT TO PERFORM SOME TESTS THESE TESTS SHOULD BE PERFORMED BY A QUALIFIED SERVICE PERSON Fan is not running Dehumidification or fan is being call...

Страница 24: ...not cover any costs related to changes to a Product or Component that may be required by any codes laws or regulations that may become effective after initial purchase of the Product by Customer Customer Responsibilities As a further condition to obtaining warranty coverage hereunder the Customer must send a valid warranty claim to Therma Stor such that Therma Stor receives such claim prior to the...

Страница 25: ...25 www Ultra Aire com 1 800 533 7533 Ultra Aire XT205H Installation Instructions ...

Страница 26: ...26 Ultra Aire XT205H Installation Instructions www Ultra Aire com 1 800 533 7533 ...

Страница 27: ...27 www Ultra Aire com 1 800 533 7533 Ultra Aire XT205H Installation Instructions ...

Страница 28: ...1 800 533 7533 www Ultra Aire com ...

Отзывы: