4
Ultra-Aire 98H Installation Instructions
www.Ultra-Aire.com | (800) 533-7533
SPECIFICATIONS
Part Number:
4034240
Blower:
320 CFM @ 0.0" WG
297 CFM @ 0.2" WG
215 CFM @ 0.4" WG
Power:
670 Watts @ 80°F and 60% RH
Supply Voltage:
115 VAC – 1phase – 60 Hz
Current Draw:
5.9 Amps
Transformer Protection:
Push Button Reset (located near power cord)
Circuit Requirement:
15 Amps
Energy Factor:
2.95 L/kWh
Operating Range:
49°F Min, 95°F Max (Inlet Air Temperature)
34°F Min, 135°F Max (Outside Cabinet)
Sized For:
Up to 2,300 Square Feet
Water Removal at:
80°F and 60% RH
70°F and 60% RH
Capacity:
98 Pints/Day
75 Pints/Day
Efficiency:
6.1 Pints/kWh
5.4 Pints/kWh
Duct Connections:
6" Round Inlet; 10" Round Inlet; 10" Round Outlet
Air Filter:
MERV-13, Mini Pleat
Efficiency:
90% ASHRAE Dust Spot
Size:
14" x 17.5" x 1.75"
Optional Air Filters:
MERV-11, Mini Pleat
Efficiency:
65% ASHRAE Dust Spot
Size:
14" x 17.5" x 1.75"
MERV-14, Embossed Pleat (will need filter housing)
Efficiency:
95% ASHRAE Dust Spot
Size:
20" x 24" x 4"
Power Cord:
9', 115VAC, Ground
Internal Insulated Cabinet:
Yes
Drain Connection:
3/4" Threaded Female NPT
Refrigerant Type:
R410A (Refer to manufacturers label for more information.)
Refrigerant Amount:
1 lb. 9 oz.
Dimensions:
Unit With Collars
Unit Without Collars
Shipping
Width:
14 1/2"
14 1/2"
23"
Height:
19 1/2"
19 1/2"
30"
Length:
32 3/8"
26"
40"
Weight:
81 lbs.
80 lbs.
95 lbs.
Side View
Front View
Rear View
32 3/8"
With Collars Installed
26"
Without Collars Installed
14 1/2"
19 1/2"
14 1/2"
19 1/2"
6" Diameter
10" Diameter
10" Diameter
Содержание 4034240