Ultra-Aire 100V Installation Instructions
www.Ultra-Aire.com | 1-800-533-7533
Air Handler
HVAC Return
HVAC Return to A/C Return
HVAC Supply
Fresh Air
Intake
(Optional)
Motorized
Damper
Ultra-Aire Supply
Ultra-Aire Supply
Air Handler
HVAC Return
HVAC Return to A/C Supply
HVAC Supply
Fresh Air
Intake
(Optional)
Backdraft Damper
Motorized
Damper
Optional Check Damper
(no HVAC fan needed)
Air Handler
HVAC Return
Dedicated Ultra-Aire 100V Return to A/C Supply
HVAC Supply
Fresh Air
Intake
(Optional)
Indoor
Air Return
Motorized
Damper
Ultra-Aire Supply
DUCTING TO HVAC SYSTEMS
Alternative HVAC System Installations
If the Recommended Dedicated Ultra-Aire Return to HVAC Supply Installation is not possible, there are several
alternative installation options available.
• DO NOT locate return in a bathroom or kitchen.
• Control should be located remotely from the dehumidifier and placed in a central location.
• For basement installations, an optional tee can be installed on the Ultra-Aire Supply.
HVAC Return to HVAC Supply
Check Damper should be in place between
the Return and Supply connections of the
dehumidifier.
If Check Damper is not in place, the
HVAC fan must turn on when the
dehumidifier is in operation.
Dedicated Ultra-Aire Return to HVAC Return
Create a separate return for the Ultra-Aire 100V in
a central area of the building.
Installing the supply air from the Ultra-Aire 100V to
the return of the HVAC system requires the HVAC
fan to run when the Ultra-Aire 100V is operating.
HVAC Return to HVAC Return
Check Damper should be in place between
the Return and Supply connections of the
dehumidifier.
Installing the supply air from the Ultra-Aire
100V to the return of the HVAC system
requires the HVAC fan to run when the
Ultra-Aire 100V is operating.
Ultra-Aire Supply
Air Handler
HVAC Return
Dedicated Ultra-Aire 100V Return to A/C Supply
HVAC Supply
Fresh Air Intake
(Optional)
Indoor
Air Return
Backdraft Damper
Motorized Damper
Dedicated Ultra-Aire Return to HVAC Supply
Create a separate return for the Ultra-Aire
100V in a central area of the building.
Duct the supply of the Ultra-Aire 100V to the
air supply of the HVAC system with a back
draft damper.
An attic insulation kit is needed for the
attic installation.