Installing the Extrusion Upgrade kit
A C A D E M Y
Replacing the build plate clamps
• Remove the glass plate.
• Place the 2 mm hex wrench on the screw in the front left corner
of the build plate. Hold the corresponding build plate screw at the
bottom of the build plate with your hand.
• Turn the build plate screw with the hex wrench to loosen the
parts completely.
• Remove the build plate clamp.
• Place the new build plate clamp between the spring and the build plate.
• Place the build plate screw with the washer around it against the bottom of the
build plate and hold it there.
• Insert the screw from the top and use the hex wrench to tighten it.
Note:
Tighten the screw until there is quite
some tension on the spring, so that the
vibrations of the build plate are reduced. But
make sure there is at least 2 mm distance
between the screw terminal of the heated
bed and the base plate.
• Repeat these steps for the
build plate clamp at the
front right of the build plate.
• Place the glass plate back
on the build plate and
close the build plate clamps.