![UL LA618 Series Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/ul/la618-series/la618-series_installation-instructions_835564003.webp)
CEILING SURFACE MOUNT INSTALLATION
Step 1:
Accessories
Step 2:
Plan hole distance, and drill 4 holes of 3.0mm φ and 1 hole of 10.0mm φ.
Step 3:
Fasten clip and elevated parts of clip with screws.
Step 4:
Fasten assembled clip kits in plastic rubber of ceiling with screws.
Step 5:
Thread AC input wire of lamp through another side of ceiling.
Step 6:
Thread screw through fixing hole of safety hole, then fasten it with clips kits.
Step 7:
According above detailed figure, first snap one side on clip kits, then rotate it to install on another
side of clip kits.
Step 8:
Connect AC according mark on the input wire, then illuminate lamp, installation finish.
A
B
C
D
FINAL INSTALLATION
E
F
G
ITEM
A. LA618 LAMP BODY
B. SCREW
C. SAFETY ROPE
D. CLIP
E. SCREW
F. ELEVATED PART OF CLIP
G. RUBBER PLUG
QTY.
1
6
2
2
2
2
4
STEP 2
STEP 3
STEP 4
STEP 5
STEP 8
STEP 6
STEP 7
STEP 1
L [BROWN]
N [BLUE]
GND [YELLOW]
DIM+ [GREY]
DIM- [BLACK]
L [BROWN]
N [BLUE]
GND [YELLOW]
DIM+ [GREY]
DIM- [BLACK]
LA618 CEILING SURFACE MONT
INSTALLATION INSTRUCTIONS
www.ullighting.net | 718.726.7500
U.L. Lighting Fixtures Corp.
Specifications and data subject to change without notice. Consult factory when critical.
Consult factory for additional configurations and options not listed or shown.
Visit our website for the most current data
Rev. 05/2017
Page 3 of 4
APPLIES TO MODELS
LA618-2, LA618-4, LA618-5