uhlmann & zacher CX8946 Скачать руководство пользователя страница 13

CX8946 

C

OMMISSIONING

 

 

12 

5

 

Commissioning 

5.1

 

Connecting locking units 

To connect a locking unit with the online module, you have to perform the 
following steps: 

 
Manual pairing 

To this purpose users must have access to the circuit board of the module to be 
able to press the button.  
 

 

Set the locking unit which you want to connect into the service mode by 
holding the service key in front of the locking unit. 

 

Pairing button 

 Keep pressed between 1 and 4 seconds. In the case of 

successful coupling the locking unit leaves the service mode before expiration 
of the regular duration of the mode.   

 

The addresses are assigned automatically in the case of manual coupling. 
Please note the information on addressing in the current protocol description.  

Function overview of the pairing button 

 

valid as of FW 2.8.36

 

Keystroke 

 

(in sec.)

 

LED  
Signaling 

Function 

0-1 

Rapid flashing 
during pairing 
(see also section 
Signaling) 

If pressed in sleep mode: 

 

Locking unit in service mode within reach is 
being coupled.
Otherwise: Briefly pressing the button ends 
the service - or manufacturer test mode.

1-4 

 

Rapid flashing 
during the service 
mode 
(see also section 
Signaling) 

 

Device can be configured. 

4-6 

No function 

6-10 

 4x

 

All locking units are uncoupled.

10-12 

 

No function 

12-16 

In mode  
flashing 1/second

 

without function for user 

16-20 

 

No function 

>20°s 

 

 

Command-driven coupling 

In this case coupling is performed via a command to the online module. This 
provides the possibility to assign an address explicitly to the knob. Furthermore 
this possibility is practical if the online module has been mounted in places that 

Содержание CX8946

Страница 1: ...CX8946 Clex Online module LAN Bluetooth Low Energy Operating and assembly instructions...

Страница 2: ...acher GmbH Gutenbergstra e 2 4 97297 Waldb ttelbrunn Germany Tel 49 931 40672 0 Email contact UundZ de www UundZ de These operating and installation instructions are protected by copyright The informa...

Страница 3: ...llation information 10 4 2 Power supply 10 4 3 Requirements for Ethernet cabling 10 4 4 Installation 11 5 Commissioning 12 5 1 Connecting locking units 12 5 2 Network identification and authentication...

Страница 4: ...acher GmbH accepts no liability for malfunctions such as impossible access to injured persons operational malfunctions damage to property or other damage resulting from non observance of these operati...

Страница 5: ...ordance with these instructions These instructions should be passed on to the user by the person carrying out the installation There is an increased risk of injury electric shock if the connecting cab...

Страница 6: ...fer of event protocols for Clex public or Clex private locking units Housing versions Housing in grey Oval housing in white Rectangular housing in white 3 1 Technical data 3 1 1 General technical data...

Страница 7: ...005 1 Screw connection for housing cover 2 Mounting holes screws not included in the scope of delivery 3 RJ45 socket Ethernet with PoE for power supply with green LED flashes during network traffic 4...

Страница 8: ...CX8946 PRODUCT DESCRIPTION 7 3 3 Structure and scope of delivery Variant gray rectangular housing...

Страница 9: ...CX8946 PRODUCT DESCRIPTION 8 White oval housing...

Страница 10: ...CX8946 PRODUCT DESCRIPTION 9 White rectangular housing...

Страница 11: ...between product and connected locking units may be influenced negatively Avoid direct exposure to strong electromagnetic fields Do not paint over paste over or cover the online module 4 2 Power supply...

Страница 12: ...gh the bottom of the housing If required drill mounting holes into the mounting surface Hand tighten the lower part of the device at the planned location using suitable flat head screws Installation m...

Страница 13: ...dressing in the current protocol description Function overview of the pairing button valid as of FW 2 8 36 Keystroke in sec LED Signaling Function 0 1 Rapid flashing during pairing see also section Si...

Страница 14: ...utive MAC addresses one for each of the basic functions of the installed LAN module The addresses will always start with E8 Example 1 E8 31 CD CD 79 5C MAC address Station Wi Fi 2 E8 31 CD CD 79 5D MA...

Страница 15: ...eb interface Start the web interface as described in the chapter Configuration of the network interface Tap on the button Info Scroll to the Wi Fi section This contains the MAC addresses Station MAC M...

Страница 16: ...reset to the factory state The pairing of the locking units remains Open the Wi Fi device menu of your mobile device Keep the button pressed Tap the reset button or optionally reconnect the LAN cable...

Страница 17: ...DHCP 5 2 4 IP address in network By default the online module can automatically obtain an IP address via DHCP when it is connected to a network The automatically assigned address can then for example...

Страница 18: ...rty system and the corresponding function of the respective protocols Individual parameters of the online module can also be set directly via a BLE connection or bus commands in the service mode Carry...

Страница 19: ...stinctive visual and acoustic signaling When the locking unit is woken up for example by a knob cylinder being turned or a door handle or knob module being actuated a wireless connection is also estab...

Страница 20: ...Wi Fi access point to carry out the initial configuration see section 5 2 3 Configuration of the network interface Green constant lighting up Network connection has been established Only for initial...

Страница 21: ...osive liquids or liquids that decompose plastic such as benzine turpentine etc Sharp detergents may damage or discolor the surface Do not use any detergents which act on a mechanical basis e g scourin...

Страница 22: ...osal 7 1 Disassembly 7 2 Disposal Do not dispose of the device with household waste but at a municipal collection point for special electrical waste in accordance with European Directive 2002 96 EC Di...

Страница 23: ...erman Verband der Elektrotechnik Registered Association of the Electrical Electronic and Information Technology PoE Power supply via Ethernet abbreviation of Power over Ethernet phg_crypt Standard pro...

Отзывы: