6.4

 

Signaling 

 

LED 

Meaning 

 

Green 
rapid flashing 

Network connection is established and IP address is 
being called 

 

Green 
slow flashing 

The module can be reached as a Wi-Fi access 
point to carry out the initial configuration (see 
section 5.2.3Fehler! Verweisquelle konnte nicht 
gefunden werden. Configuration of the network 
interface)
 

 

Green 
constant lighting 
up 

Network connection has been established 
(Only for initial connecting. No function for 
disconnection during operation) 

 

Red LED 

Is currently not used 

 
 

6.5

 

Malfunctions during operation/error signaling 

 

LED 

Meaning 

 

Red and yellow 
flashing after a 
reset; after that 
service mode   

Mode wrong for the available firmware:  
Perform a suitable firmware update. 

 

Yellow lights up 
constantly after a 
reset 

Micro-controller of the device is in boot loader mode. 
Perform a suitable firmware update. 

 

 

6.6

 

Maintenance 

Since the device is not protected specially against dust, the product should be 
checked regularly for dust deposits. The frequency depends on the dust level at 
the operation site. 

6.7

 

Cleaning 

Clean the housing with a soft, lint-free and only slightly moistened cloth. When 
cleaning do not use corrosive liquids or liquids that decompose plastic such as 
benzine, turpentine, etc.  
Sharp detergents may damage or discolor the surface. Do not use any 
detergents, which act on a mechanical basis (e.g. scouring milk, scouring 
sponge). 
 
Free the electronics from dust with a suitable brush or by careful use of 
compressed air at a sufficient distance.     
 

 

16 

17 

Содержание CX8942

Страница 1: ...CX8942 Clex Online module LAN 868 MHz Operating and assembly instructions Valid from HW 1 5 3_A ESP MOD 5 0 1...

Страница 2: ...Gutenbergstra e 2 4 97297 Waldb ttelbrunn Germany Tel 49 931 40672 0 Email contact UundZ de www UundZ de These operating and installation instructions are protected by copyright The information contai...

Страница 3: ...llation information 10 4 2 Power supply 10 4 3 Requirements for Ethernet cabling 10 4 4 Installation 11 5 Commissioning 12 5 1 Connecting locking units 12 5 2 Network identification and authentication...

Страница 4: ...her GmbH accepts no liability for malfunctions such as impossible access to injured persons operational malfunctions damage to property or other damage resulting from non observance of these operating...

Страница 5: ...with these instructions These instructions should be passed on to the user by the person carrying out the installation There is an increased risk of injury electric shock if the connecting cables are...

Страница 6: ...tocols for Clex public or Clex private locking units Housing versions Housing in grey Oval housing in white Rectangular housing in white 3 1 Technical data 3 1 1 General technical data Designation Val...

Страница 7: ...ope of delivery 1 RS485 B optional 2 RS485 A optional 3 Power supply 4 Power supply 5 Digital input 6 Relay CO 7 Relay NO 8 RJ45 socket Ethernet with PoE for power supply with green LED flashes during...

Страница 8: ...CX8942 PRODUCT DESCRIPTION 7 3 3 Structure and scope of delivery Variant gray rectangular housing...

Страница 9: ...CX8942 PRODUCT DESCRIPTION 8 White oval housing...

Страница 10: ...CX8942 PRODUCT DESCRIPTION 9 White rectangular housing...

Страница 11: ...y be influenced negatively Avoid direct exposure to strong electromagnetic fields Do not paint over paste over or cover the online module 4 2 Power supply The CX8942 can be supplied with voltage eithe...

Страница 12: ...gh the bottom of the housing If required drill mounting holes into the mounting surface Hand tighten the lower part of the device at the planned location using suitable flat head screws Installation m...

Страница 13: ...leaves the service mode prematurely If required repeat the process by coupling further locking units in service mode by pressing the button Function rotary switch Position Function 0 Basic position 4...

Страница 14: ...address LAN The MAC address of the online module can be determined in different ways You can find the MAC address of the device coded in the data matrix installed on the LAN module Scan the data matr...

Страница 15: ...t to the factory state The pairing of the locking units remains Open the Wi Fi device menu of your mobile device Keep the button pressed Tap the reset button or optionally reconnect the LAN cable Cont...

Страница 16: ...DHCP 5 2 4 IP address in network By default the online module can automatically obtain an IP address via DHCP when it is connected to a network The automatically assigned address can then for example...

Страница 17: ...y system and the corresponding function of the respective protocols Individual parameters of the online module can also be set directly via a 868 MHz connection or bus commands in the service mode Car...

Страница 18: ...ic signaling When the locking unit is woken up for example by a knob cylinder being turned or a door handle or knob module being actuated a wireless connection is also established 6 1 Reset Tap the re...

Страница 19: ...ong for the available firmware Perform a suitable firmware update Yellow lights up constantly after a reset Micro controller of the device is in boot loader mode Perform a suitable firmware update 6 6...

Страница 20: ...osal 7 1 Disassembly 7 2 Disposal Do not dispose of the device with household waste but at a municipal collection point for special electrical waste in accordance with European Directive 2002 96 EC Di...

Страница 21: ...der Elektrotechnik Registered Association of the Electrical Electronic and Information Technology PoE Power supply via Ethernet abbreviation of Power over Ethernet phg_crypt Standard protocol of the...

Отзывы: