background image

CX8936 

S

AFETY

 

 

2

 

Safety 

2.1

 

Proper use 

The product is intended for use solely with Bluetooth

® 

-capable devices. It is de-

termined for use in the system Clex public and can be operated with locking units 
from other systems by Uhlmann & Zacher. 
The  device is  designed  for the  surface  mounting in  secured  indoor areas.  Only 
components approved by the Uhlmann & Zacher GmbH may be used for installa-
tion and maintenance. 
Installation may only be carried out by trained specialist personnel. 
Any other use is considered  improper and may result in  damage to property  or 
even personal injury. 
 

2.2

 

Improper use 

 

The product must not be used to lock up aids that are vital in an emer-
gency (for example, defibrillators, emergency medication, fire extinguish-
ers, etc.). 

 

The product must not be used in potentially explosive atmospheres. 

 

If the housing or the electronics are damaged, the product must not be 
operated any longer. Modifications or additions to the product are not 
permitted. Usage outside the stated specifications is not permitted. 

 

2.3

 

General safety information 

Observe the following basic safety instructions when handling the wall mounted 
reader: 

 

No modifications of any kind are permitted to the product, with the ex-
ception of those described in this manual. 

 

Installation may only be carried out by trained specialists in accordance 
with these instructions. 

 

The product must only be operated in the defined temperature range. 

 

There is an increased risk of injury (electric shock!) if the connecting ca-
bles are touched when the power supply is switched on. Only perform in-
stallation and maintenance work when the power supply is switched off. 
Observe VDE guidelines! 

 

These instructions should be passed on to the user by the person carrying 
out the installation. 

 

The product must not be brought into contact with paints or acids 

 

To avoid malfunctions and damage, only use original parts and accesso-
ries from Uhlmann & Zacher GmbH. 

 

Содержание CX8936

Страница 1: ...CX8936 Online module with Bluetooth Low Energy Operating and installation instructions...

Страница 2: ...r GmbH Gutenbergstra e 2 4 97297 Waldb ttelbrunn Germany Tel 49 931 40672 0 Email contact UundZ de www UundZ de These operating and installation instructions are protected by copyright The in formatio...

Страница 3: ...Installation 10 4 1 General installation information 10 4 2 Installation 10 4 3 Pin assignment 11 5 Commissioning and operation 12 5 1 Connecting locking units 12 5 2 Configuring the online module 13...

Страница 4: ...on Uhlmann Zacher GmbH accepts no liability for malfunctions such as impossi ble access to injured persons operational malfunctions damage to property or other damage resulting from non observance of...

Страница 5: ...the product must not be operated any longer Modifications or additions to the product are not permitted Usage outside the stated specifications is not permitted 2 3 General safety information Observe...

Страница 6: ...on the device version No external antenna is required for the connection 3 2 Layout and scope of delivery Layout using the example of the grey housing version Other housing versions similar 1 Housing...

Страница 7: ...in white 3 4 Technical data 3 4 1 General technical data Designation Value Number of cou pleable locking units depending on versions For data transfer via RS485 8 For Wiegand clock data 1 Frequency ra...

Страница 8: ...CX8936 PRODUCT DESCRIPTION 7 3 5 Dimensions Grey housing...

Страница 9: ...CX8936 PRODUCT DESCRIPTION 8 White oval housing...

Страница 10: ...CX8936 PRODUCT DESCRIPTION 9 White rectangular housing...

Страница 11: ...is smooth dry and firm enough Do not place the units close to each other to avoid radio interfer ences Mark the fastening points through the bottom of the housing No 9 in layout diagram If required dr...

Страница 12: ...th pin 6 7 8 insulated against ground connection not used 4 Wiegand 0 5 Wiegand 1 6 7 8 Input potential 5 24 V not used 9 power supply 5 24 VDC can be used alternatively to 1 10 power supply ground ca...

Страница 13: ...If not successful the red LED lights up several times and the lock remains in the service mode The yellow LED flashes additionally to confirm the button input The blue LED flashes to signal the BLE ac...

Страница 14: ...and test the connection via the Clex public UZ Reader protocol The parameters for the Wiegand connection can also be set with this tool Con tact your Integration partner to purchase the software The C...

Страница 15: ...its Blue constant lighting up All paired locking units are connected Blue rapid flashing Device tries to wake up a locking unit in the wake on radio mode WOR Yellow Button input Red Active online conn...

Страница 16: ...6 2 Cleaning Clean the housing with a soft lint free and only slightly moistened cloth When cleaning do not use corrosive liquids or liquids that decompose plastic such as benzine turpentine etc Shar...

Страница 17: ...sal 7 1 Disassembly 7 2 Disposal Do not dispose of the device with household waste but at a municipal col lection point for special electrical waste in accordance with European Di rective 2002 96 EC D...

Страница 18: ...g BLE Bluetooth Low Energy VDE German Verband der Elektrotechnik Registered Asso ciation of the Electrical Electronic and Information Technology phg_crypt Standard protocol of the company phg Peter He...

Отзывы: