background image

CX2936 

P

RODUCT DESCRIPTION

 

 

3.2

 

Versions 

Housing versions:  

 

Housing in grey 

 

Oval housing in white 

 

Rectangular housing in white 
 

3.3

 

Technical data 

3.3.1

 

General technical data 

 

Designation 

Value 

Number of cou-
pleable locking units 

Frequency range 

2402 to 2480 MHz 

Power supply 

Supply voltage 5-24 VDC 

Power consumption 

Max. 0.4 W 

Switching input 

High: 5-24 VDC 
Low: 0 VDC 

 

 

3.3.2

 

Ambient conditions 

 

Designation 

Value 

Operating tempera-
ture 

+10 °C to +55 °C 
 

Storage temperature 

-40 °C to +65 °C 

Installation location 

Indoors 

 

 

Содержание CX2936

Страница 1: ...CX2936 Clex private wireless switch module with Bluetooth Low Energy Operating and installation instructions...

Страница 2: ...lmann Zacher GmbH Gutenbergstra e 2 4 97297 Waldb ttelbrunn Germany Tel 49 931 40672 0 Email contact UundZ de www UundZ de These operating and installation instructions are protected by copyright The...

Страница 3: ...ata 6 3 4 Dimensions 7 4 Installation 10 4 1 General installation information 10 4 2 Installation 10 4 3 Pin assignment 11 5 Commissioning and operation 12 5 1 Connecting the locking unit 12 5 2 Opera...

Страница 4: ...hem with operation Uhlmann Zacher GmbH accepts no liability for malfunctions such as impossi ble access to injured persons operational malfunctions damage to property or other damage resulting from no...

Страница 5: ...er Modifications or additions to the product are not permitted Usage outside the stated specifications is not permitted 2 3 General safety information Observe the following basic safety instructions w...

Страница 6: ...an opening command from the wireless switch module via the 2 4 GHz range There is a 1 1 assignment between the wireless switch module and the locking unit Layout and scope of delivery Layout using the...

Страница 7: ...ral technical data Designation Value Number of cou pleable locking units 1 Frequency range 2402 to 2480 MHz Power supply Supply voltage 5 24 VDC Power consumption Max 0 4 W Switching input High 5 24 V...

Страница 8: ...CX2936 PRODUCT DESCRIPTION 7 3 4 Dimensions Grey housing...

Страница 9: ...CX2936 PRODUCT DESCRIPTION 8 White oval housing...

Страница 10: ...CX2936 PRODUCT DESCRIPTION 9 White rectangular housing...

Страница 11: ...ace is smooth dry and firm enough Do not place the units close to each other to avoid radio interfer ences Mark the fastening points through the bottom of the housing No 9 in layout diagram If require...

Страница 12: ...e supply ground together with Pin 6 7 8 4 Wiegand 0 not used 5 Wiegand 1 not used 6 Input not used 7 Input not used 8 Input potential 5 24 VDC 9 power supply 5 24 VDC can be used alternatively to 1 10...

Страница 13: ...s the service mode directly If not successful the red LED lights up several times and the lock remains in the service mode The yellow LED flashes additionally to confirm the button input The blue LED...

Страница 14: ...fly press the button 7 to delete all the saved lock ing units and parameters 5 5 Firmware updates The update tool Clex FW Prog is available to update the firmware Contact your respective dealer or Int...

Страница 15: ...w flash after a reset after that service mode Mode wrong for the available firmware Perform a firmware update or set the mode manually Yellow lights constant ly after a reset Micro controller of the d...

Страница 16: ...6 2 Cleaning Clean the housing with a soft lint free and only slightly moistened cloth When cleaning do not use corrosive liquids or liquids that decompose plastic such as benzine turpentine etc Shar...

Страница 17: ...al Do not dispose of the device with household waste but at a municipal col lection point for special electrical waste in accordance with European Di rective 2002 96 EC Dispose of packaging as environ...

Страница 18: ...CX2936 GLOSSARY 17 8 Glossary Term Meaning BLE Bluetooth Low Energy VDE German Verband der Elektrotechnik Registered Asso ciation of the Electrical Electronic and Information Technology...

Отзывы: