CX2122/24/26
C
OMMISSIONING
14
5
Commissioning
Basically, there are two ways to manage a Clex private locking system and
thereby programming the CX212x knob module:
Management as learning / clearing system
Management using the CX2530 Keyng software and radio stick /
programming station
5.1
Memorize service key
In its original condition (delivery status), the service key has not been memorized
by the knob module. To memorize the service key, the knob module is woken up
by holding a key in front of the reading unit. Upon success, the knob model
responds with three long audible signals. Within the next 15 seconds, the service
key can be memorized by holding it in front of the reading unit. Once the service
key has been memorized successfully, the knob module indicates this with two
short and one long audible signals.
After memorizing, the knob module enters the programming mode when the
service key is presented.
5.2
Management as learning / clearing system
5.2.1
Memorize battery change and disassembly card
After memorizing the service key, the battery change and the disassembly card
also need to be memorized. To do this, first hold the service key in front of the
knob module, followed by the battery change card and finally the disassembly
card.
5.2.2
Memorize key
Hold the service key in front of the reading unit of the knob module. The
knob module enters the programming mode.
Hold the key to be memorized in front of the reading unit until two short
audible signals indicate success.
Optionally, memorize more keys as described in the previous step.
Hold the service key in front of the reading unit or wait 15 seconds to exit the
programming mode.
To create a key with toggle authorization, hold the key for 3 seconds in front of
the reading unit during the memorize process until the success is indicated by 3
short audible signals.
5.2.3
Delete key
Hold the service key in front of the reading unit of the knob module. The
knob module enters the programming mode.
Hold the key to be deleted in front of the reading unit until two long audible
signals indicate success.
Optionally, delete more keys as described in the previous step
.
Hold the service key in front of the reading unit or wait 15 seconds to exit the
programming mode.