![Uhlenbrock Elektronik IntelliLight LED Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/uhlenbrock-elektronik/intellilight-led/intellilight-led_manual_3266410006.webp)
- 6 -
Strobe lamp:
The strobe lamp is attached to the mount with 2 screw lugs on the base board. The
plug from the strobe lamp is plugged into connector 4 (Blitz (Strobe)) on any main
lighting stick.
Chassis, white
Lightning power, yellow
Sound module:
Plug the small four way SUSI connector from the Sound module into connector 3
(SUSI) of any Main lighting stick. Attach the Sound module with the enclosed adhesive
pad close to the SUSI socket. Attach the loudspeaker as required, close to the Sound
module.
5.4 Connecting LED Luminaires
For precise illumination (e.g. Spot) a dimmable 12V LED Luminaire can be connected
to the 2-way screw terminal. The maximum load capacity of the luminaire is 2 W.
Take care on the correct polarity. In the diagram of the main lighting stick (see Chap
5.1) the terminal is marked with "+" and "-".
5.5 Connecting LocoNet for Digital operation
In order to trigger the light or weather events with solenoid addresses, for example, or
from the IntelliLight LED to switch the house lights in synch with the time of day,
connect the LocoNet socket from the control module with the LocoNet of your digital
center (Intellibox, DAISY II DCC Digitalset, SC7, Märklin 6021 with 6021-Infrared &
LocoNet-Adapter, TwinCenter, Piko Power Box). Use the 60 cm LocoNet cable from
the Starter set.
5.6 Connecting the IntelliLight 28 000
If an IntelliLight 28 000 already exists and is to be extended with an IntelliLight LED the
main lighting stick from IntelliLight LED connector 5 is connected with the data line
from the IntelliLight 28 000 as shown in the sketch. For that the 4-way connector
socket on the base unit 28 000 or an expansion unit 28 010 or 28 020 can be used.
For this connection you must make an appropriate cable from a LocoNet cable. Cut a
plug off a LocoNet cable and approximately 5cm of the outer insulation. Now connect
the wires as follows, (e.g. soldering or terminal clips) wires 2 and 5 together. After that
3 and 4. The resulting double line 2 & 5 is screwed to terminal 2 (GND) of the
connector on the IntelliLight Base or Expansion module. Double line 3 & 4 is then
connected to terminal 3 (LN) of the connector. Wires 1 and 6 of this LocoNet cable
remain insulated and unused.