background image

Operating Manual 

UMP-1 BT 

Version: 22/05/19

 

 

 

Umwelt-Geräte-Technik GmbH

  |  Eberswalder Str. 58  |  D-15374 Müncheberg  |  Tel.: +49 (0) 33 43 2 - 89 575 |  

www.ugt-online.de

          Seite 1 von 17 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UMP-1 combined soil humidity, conductivity and temperature 

sensor 

 
 

Содержание UMP-1

Страница 1: ...l UMP 1 BT Version 22 05 19 Umwelt Ger te Technik GmbH Eberswalder Str 58 D 15374 M ncheberg Tel 49 0 33 43 2 89 575 www ugt online de Seite 1 von 17 UMP 1 combined soil humidity conductivity and temp...

Страница 2: ...nformation 5 2 1 Structure and basic function 5 2 2 Technical data 6 3 Volumetric water content of the soil 7 4 Mode of operation 7 4 1 Water content measurement 7 4 2 Electrical conductivity measurem...

Страница 3: ...rement and time spent on installation and servicing In addition soil disturbance is reduced because only one sensor has to be installed in order to measure three soil properties In Addition to the cab...

Страница 4: ...any questions or feedback Email info ugt online de or support ugt online de Phone 49 0 33432 89 575 Fax 49 0 33432 89 573 If contacting us by email or fax please include as part of your message your...

Страница 5: ...be completely buried for a depth or horizontal installation It is made of plastic or stainless steel while the measuring rods antennas are always made of stainless steel Regular maintenance is not nec...

Страница 6: ...24V DC Power input 60 mA Water content Measurement range 0 100 vol water content Accuracy 2 Resolution 0 1 vol water content Electrical conductivity Measurement range 0 001 4mS cm Optional measuremen...

Страница 7: ...er to the FDR sensors nor the TDR sensors The basic mode of operation however corresponds to the FDR process because the sensor operates with a continuous signal at constant frequency 60 MHz and not w...

Страница 8: ...ent is interrupted for a sort time and a signal in the kHz range transmitted over the antennae The corresponding IC measures the impedance of several different frequencies and averages the results 4 3...

Страница 9: ...es fast work for taking many single measurements in a row Despite the different design the two probes hardly vary in the basics of operation just in the practical adjustment to their core tasks By pre...

Страница 10: ...cap of the charge socket bajonet cap and connect the probe to either the USB port of your PC or a socket using the provided cable and adapter 7 Data output 7 1 App Installation The app is already inst...

Страница 11: ...ity is available install a free file manager from the App Store for example the ES File Explorer and use this to click on the copied file 5 Select Install and follow the instructions on the screen 6 A...

Страница 12: ...probes listed in this view are possible The use of Bluetooth restricts the maximum number of simultaneous connections to 7 although the actual app can manage more than 7 probes This dialogue also pro...

Страница 13: ...ave been successfully implemented the dialogue closes and the main menu reappears If the dialogue does not close automatically a fault has occurred with at least one probe and is displayed in Box 2 of...

Страница 14: ...t Temperature in C Conductivity mS cm a View as graph In this view mode the measured data are displayed as chart 30 measurements are always displayed simultaneously and continuously From 5 measurement...

Страница 15: ...ts The recorded files are stored in the external memory of the device so that the files can be downloaded e g to a PC The first time recording takes place the folder UMP1 is created in the file system...

Страница 16: ...reen orientation should be portrait or landscape Disable large images prevent large images such as background images being used in the app 7 3 Troubleshooting Error code Description Causes solutions 1...

Страница 17: ...74 M ncheberg Tel 49 0 33 43 2 89 575 www ugt online de Seite 17 von 17 Can t access file 6 Fehler beim Datei lesen Can t read file 7 Falsches Dateiformat Wrong file format 8 Interner Systemfehler Int...

Отзывы: