Ugolini CADDY UL Скачать руководство пользователя страница 6

6

CADDY UL

prior to starting the machine. Do not allow the
unit to sit for extended periods of time after
sanitization.

1

Wash hands with a suitable antibacterial

soap.

2

Prepare at least two gallons of a warm (45-

60 °C 120-140 °F) sanitizing solution (100 PPM
available chlorine concentration or 1 spoon of
sodium hypoclorite diluted with two litres of
water) according to your local Health Codes and
manufacturer’s specifications.

3

Place the parts in the sanitizing solution

following manifacture ‘s specifications (about five
minutes).

4

Place the sanitized parts on a clean dry

surface to air dry.

5

Wipe clean all exterior surfaces of the unit.

Do not use abrasive cleaner.

5. 3. 4 ASSEMBLY

1

Slide the drip tray into place.

2

Pinch tube faucet: 

push the dispensing

handle (1) and insert the pinch tube into its
vertical seat in the bowl bottom(2). Lightly pull
the pinch tube end downwards til itl is well
arranged (3) (see figure 5).

figure 5

3

Gravity faucet

: install the faucet handle (1-

2) and the piston with its gasket (3) (see figure

6).

figure 6

4

Fit the bowl gasket to the evaporator. Note:

the largest brim of the gasket must face against

the drip plate (see figure 8). 

figure 7

5

Place bowl on the unit. Wet the gasket for

ease of insertion.

CADDY 5/2 - 5/3 - 5/4

: be sure first that the

faucet top (1) is under the tooth jutting (2) out of

the drip plate (see figure 8).

Содержание CADDY UL

Страница 1: ...CADDY UL OPERATOR S MANUAL...

Страница 2: ...g to the applicable electrical codes and the specifications of your machine When the unit has no plug install a proper grounded plug in compliance with electrical codes in force in your area suitable...

Страница 3: ...n in chapter 5 1 DESCRIPTION OF CONTROLS 6 The dispenser must always run with the covers installed to prevent a possible contamination of the product 7 Always leave the dispenser on as the refrigerati...

Страница 4: ...ing and sanitizing of the dispenser are recommended to guarantee the conservation of the best product taste and the highest unit efficiency This section is a procedural guideline only and is subject t...

Страница 5: ...pose thoroughly clean all disassembled parts in the cleaning solution 3 Rinse all cleaned parts with cool clean water 5 3 3 SANITIZING Sanitizing should be performed immediately IMPORTANT Do not attem...

Страница 6: ...y surface to air dry 5 Wipe clean all exterior surfaces of the unit Do not use abrasive cleaner 5 3 4 ASSEMBLY 1 Slide the drip tray into place 2 Pinch tube faucet push the dispensing handle 1 and ins...

Страница 7: ...all surfaces protruding above the solution level and on the underside of the top cover s 4 Install the top cover s and operate the unit Allow the solution to agitate for about two minutes Drain the s...

Страница 8: ...000 Faucet spring 5 21704 00000 Rubber spring retainer 6 21701 00001 Push handle 7 21983 00000 Pump cover fixing clip 8 33800 05700 Evaporator assembly 9 21125 00000 Switch 10 22800 05100 Switch cap 1...

Страница 9: ...1 Thermostat 27 22800 18301 Cabinet for Caddy 7 1 10 1 27 22800 18321 Cabinet for Caddy 10 2 28 22800 10000 Leg 29 22800 05500 Terminal block with cable clamp 30 22800 20700 Fan 31 01702 00000 Faucet...

Страница 10: ...00001 Push handle 5 33800 05710 Evaporator assembly 5 33800 05762 Evaporator assembly Caddy 5 3 6 21125 00000 Switch 7 22800 05100 Switch cap 8 21087 00000 Thermostat 9 33900 01051 Pulley magnet and s...

Страница 11: ...ity faucet 23 22800 17200 Bowl gasket 24 33800 05401 Pump impeller 25 22800 19900 Central pivot 26 22040 00000 Central pivot OR 27 21983 00000 Pump cover retainer 28 10554 45000 Clip 29 22800 18301 Ca...

Страница 12: ...2441_02 R3 3 05B04 Ugolini spa Via dei Pioppi 33 20090 Opera MI Tel 02 530059 1 Fax 02 530059260 www ugolinispa com E Mail sales ugolinispa com...

Отзывы: