UGO BASILE 37215 Скачать руководство пользователя страница 18

 

Page 12  

37215 Instruction Manual (Rev. 4)

 

  

6.4 

Long Inactivity  

The instrument does not require any particular maintenance after long inactivity, except 
cleaning.  

6.5 

Customer Support  

For any further information you may desire concerning the use and/or maintenance of the 
Analgesy-Meter  and  accessories,  please  do  not  hesitate  to  contact  our 

service  depart-

ment

 (or our local distributor) either directly of via our 

contact page

:   

 

UGO BASILE s.r.l. 

Via G. Di Vittorio 2 
21036 GEMONIO – Varese, ITALY 

 

Phone :   +39  0332  744574 

 

[email protected]   
[email protected] 
[email protected] 

Before sending any instrument to our factory for repair

, please contact our logistics 

department to obtain a return authorization number (RMA) and shipping/packing instruc-
tions.  

We  may  not  be  held  responsible  for  damages  during  transport  due  to  poor  packing; 
whenever possible, please use the original packing. 

ORDERING INFORMATION 

37215

 

Analgesy-Meter, standard

, complete with following standard accesso-

ries:

 

37215-303 

Pedal Switch, complete with cable 

37215-322 

Standard Pusher (1) 

37215-323 

2 Additional discs Disc M-LM 446 (9), see also 2.2.1 

E-WP 008 

Mains Cord 

E-FT 001-1 

2 Fuses T125mA 

E-AU 041 

USB pen drive, including: 

 

37215-302 

Instruction Manual (on USB pen drive) 

 

37216

 

Analgesy-Meter, low pressure model, suitable for Mouse

, with 

following standard accessories:

 

Содержание 37215

Страница 1: ...ANALGESY METER ugobasile com Cat No 37215 Pain and Inflammation Instruction manual...

Страница 2: ...the instrument in safe conditions Service and adjustments should be carried out by qualified personnel authorizedbyugobasileorganization Any adjustment maintenance and repair of the opened instrument...

Страница 3: ...he Analgesy Meter in a fully digital device As the basic design is unchanged results with the digital model are consistent with published data The upgrade kit has been designed to be fitted on existin...

Страница 4: ...M CM 458 F 1 37215 303 1 PEDAL SWITCH PEDALE E FT 001 1 2 FUSE T125mA FUSIBILE T125mA M LM 716 F 37216 323 2 ADDITIONAL DISC 37216 PESO AGGIUNTIVO 37216 M LM 446 37215 322 1 STANDARD PUSHER cone shap...

Страница 5: ...ECTOR 5 3 3 3 MAINS CORD 5 3 4 CONNECTIONS 6 3 5 INTENDED USE 6 3 6 GENERAL SAFETY INSTRUCTIONS 6 3 7 ADDITIONAL SAFETY CONSIDERATION 6 3 8 NOTICE FOR THE CUSTOMERS IN JAPAN 7 4 OPERATION 7 4 1 PRELIM...

Страница 6: ...D 14 7 6 REFERENCE TO UB ANALGESY METER RAT 14 7 7 REFERENCE TO UB ANALGESY METER MOUSE 15 FIGURE INDEX Figure 1 Front View 2 Figure 2 Back View 3 Figure 3 Back Panel 5 Figure 4 Analgesy Meter 37215 w...

Страница 7: ...exerts a force increasing at a constant rate a certain number of grams per second This force is continuously monitored by a pointer moving along a linear scale The force is applied to the animal s pa...

Страница 8: ...d mouse model 37216 is also available when lower pressure 50 is desirable The 37216 in cludes a specific slide and 50 reduced additional weights a standard and a chisel shaped pusher which make easier...

Страница 9: ...d to increase the force on the paw at a rate of 16 grams per second 16x2 with one disc added 16x3 with two The rate at which the force increases has been found to be a satisfactory compromise for norm...

Страница 10: ...there are not addi tional discs the calibrated weight of the slide includes the nut 3 INSTALLATION 3 1 Unpacking Preliminary Check Check the contents of the shipment for completeness packing list to h...

Страница 11: ...itch This two pole toggle switch which complies with international safety standards provides a visual cue meaning OFF when pressed to the right O side ON when pressed to the left I side 3 3 2 Fuse Hol...

Страница 12: ...oes not cause any circuit damage For connection to the optional Analgesy Meter DAQ 37215 100 please refer to the re lated instruction manual 3 5 Intended Use The Analgesy Meter is intended for investi...

Страница 13: ...rent rate may impair the experiment consistency in particular if you compare the results gathered by two Analgesy Meters and one of them is fed by the wrong mains frequency In case of doubt ask for ad...

Страница 14: ...hts 4 3 1 Standard Model 37215 Ruler 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 cm no weight 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 2...

Страница 15: ...dels too For operation please refer to the 37215 100 specific manual Figure 5 Optional Pressure transducer Keep in mind that the readings obtained on the mechanical scale and those obtained by the ele...

Страница 16: ...bearings are designed to operate mainte nance free DO NOT LUBRICATE 6 2 Electrical To inspect and or replace the fuses disconnect the mains cable first Insert a minia ture screwdriver in the slot ind...

Страница 17: ...includes A specific slide A chisel shaped pusher Two 50 reduced additional weights The replacement is easily done following the steps indicated in the drawing below 1 slacken the two screws and the r...

Страница 18: ...ile com Before sending any instrument to our factory for repair please contact our logistics department to obtain a return authorization number RMA and shipping packing instruc tions We may not be hel...

Страница 19: ...5 324 Counterweight 10 complete with DELRIN set screw 37215 325 Slide Plastic Pad helical tooth which engages the driving screw NOTE Analgesy Meter is available for operation at 115 or 230 Volts 50 or...

Страница 20: ...ethod L O Randall and J J Selitto A Method for Measurement of Analgesic Ac tivity on Inflamed Tissue Arch Int Pharmacodyn CXI No 4 409 419 1957 7 6 Reference to UB Analgesy Meter Rat E K Joseph et ali...

Страница 21: ...9 7 7 Reference to UB Analgesy Meter Mouse K Sugimoto et alia The Impact of Low Dose Insulin on Peripheral Nerve Insulin Receptor Signaling in Streptozotocin Induced Diabetic Rats PLoS ONE 8 8 e74247...

Страница 22: ..._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Страница 23: ..._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Страница 24: ..._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Страница 25: ...red in compliance with the following European Union Directives and relevant harmonized standards 2014 35 UE relating to electrical equipment designed for use within certain voltage limits 2014 30 UE r...

Страница 26: ...sales ugobasile com Pain and Inflammation Ventilators and Gas Anesthesia Behaviour Conditioning Reward Behaviour Mazes Tracking Tissue baths Transducers Recorders Miscellaneous ECT LMD Blood Pressure...

Отзывы: