10
CONNECTION – 0-10V OPERATION
There are 3 connections required – the fiber port, the mains supply cable and
the 0-10V cable. The fiber port should be connected first. Connect and secure
the fiber optic connector into the aluminium collar and secure using the M5
locking screw.
Connect the IEC power cord into the Desk Top PSU and plug the mains plug
into the electrical supply socket. Switch on power the led indicator will
illuminate and the illuminator is ready for use. In no light is produced consult
the TROUBLESHOOTING section.
Connect the 0-10V RJ45 as detailed below using CAT5 cable.
NOTE:
for Emergency Light functionality, the mains supply for the illuminator
must be maintained so that failure of the mains supply to the 0-10V controller
will result in the illuminator lighting at maximum output.
0-10V RJ45 Connections:
-VE RJ45 Brown/White (Pin 7)
+VE RJ45 Blue/White (Pin 5)