INSTALLATION
4
There are 4 connections required – the 2 fibre ports and the mains supply. The fibre port
should be connected first. Connect and secure the fibre optic connector into the front of the
unit and secure using the M5 locking screw
Plug the mains plug into the electrical supply socket. Switch on power the led Indicator will
illuminate and the light source will start up automatically. If no light is produced consult the
TROUBLESHOOTING section
NOTE: THESE LIGHT SOURCES ARE NOT MAINS DIMMABLE.
Now, connect up the RJ45 cable between the Master Light Source and the Slave or the
Remote Controller and the Slave, using the RJ45 sockets provided on the back of the light
source – it doesn’t matter which socket is used.
There are three modes of Slave operation – Standalone, Master/Slave and Remote DMX.
STANDALONE OPERATION
To use the Slave in manual standalone operation remove the DMX connector from the RJ45
socket at the rear of the Slave and it will now respond to manual commands from the 2
control buttons as detailed below.
OPERATION
The LED Light source has 2 colour cycles each with 3 different speed settings as
detailed below:
CONNECTION
MICROLED
2000
USER
GUIDE
Cycle
Colour 1
Colour 2
Colour 3
Colour 4
Colour 5
Colour 6
Colour 7
1
White
Red
Orange
Jade
Green
Cyan
Blue
2
Pink
Red
Orange
Jade
Green
Cyan
Blue
The Light Source is controlled using the 2 push buttons on the rear of the unit.
The Lower button STOPS and STARTS the colour Cycle
The Upper button is used to select the Cycle speed as follows. Push the Lower button
repeatedly until the colour White is displayed. The light source is now in Cycle 1 speed A as
detailed below. Each push reduces the speed. On the third push the colour Red will be
displayed. The light source is now in Cycle 2 speed A.