INSTALLATION

4

There are 4 connections required – the 2 fibre ports and the mains supply. The fibre port 
should be connected first. Connect and secure the fibre optic connector into the front of the 
unit and secure using the M5 locking screw 
 
Plug the mains plug into the electrical supply socket. Switch on power the led Indicator will 
illuminate and the light source will start up automatically. If no light is produced consult the 
TROUBLESHOOTING section 
 

NOTE: THESE LIGHT SOURCES ARE NOT MAINS DIMMABLE. 
 

Now, connect up the RJ45 cable between the Master Light Source and the Slave or the 
Remote Controller and the Slave, using the RJ45 sockets provided on the back of the light 
source – it doesn’t matter which socket is used. 
 
There are three modes of Slave operation – Standalone, Master/Slave and Remote DMX. 
 

STANDALONE OPERATION

 

 
To use the Slave in manual standalone operation remove the DMX connector from the RJ45 
socket at the rear of the Slave and it will now respond to manual commands from the 2 
control buttons as detailed below. 
 

OPERATION 

 
The LED Light source has 2 colour cycles each with 3 different speed settings as  
detailed below: 

CONNECTION

MICROLED

 

2000

 

USER

 

GUIDE

Cycle

Colour 1

Colour 2

Colour 3

Colour 4

Colour 5

Colour 6

Colour 7

1

White

Red

Orange

Jade

Green

Cyan

Blue

2

Pink

Red

Orange

Jade

Green

Cyan

Blue

The Light Source is controlled using the 2 push buttons on the rear of the unit. 
The Lower button STOPS and STARTS the colour Cycle 
The Upper button is used to select the Cycle speed as follows. Push the Lower button 
repeatedly until the colour White is displayed. The light source is now in Cycle 1 speed A as 
detailed below. Each push reduces the speed. On the third push the colour Red will be 
displayed. The light source is now in Cycle 2 speed A.

Содержание MICROLED 2000

Страница 1: ...FO LIGHTING FIBRE OPTIC LED LIGHTING SYSTEMS REVISION B2 MICROLED 2000 LIGHT SOURCE USER GUIDE PLEASE READ THIS USER GUIDE BEFORE INSTALLING OPERATING OR PERFORMING MAINTENANCE ON THE LIGHT SOURCE UNI...

Страница 2: ...ource is set up optimally and gives a long service life please read this user guide before installing operating or performing any maintenance on the unit This light source is suitable for indoor use o...

Страница 3: ...T FIT BATTERIES TO THE REMOTE CONTROL UNTIL YOU HAVE FULLY READ THE INSTRUCTIONS ON PAGE 4 The LED light source is powered from a multi function multi voltage desk top Power Supply Unit Remove the SW4...

Страница 4: ...e and Remote DMX STANDALONE OPERATION To use the Slave in manual standalone operation remove the DMX connector from the RJ45 socket at the rear of the Slave and it will now respond to manual commands...

Страница 5: ...Lower push button To use the Slave in DMX operation connect a DMX Cat5 cable between one of the RJ45 sockets at the rear of the Slave Light Source and the DMX Controller see RJ45 connection details a...

Страница 6: ...ed Each Light Source occupies 4 DMX channels see Channel Table below Channel Function Value Description 1 Colour RED 0 255 From OFF at 0 to BRIGHT AT 255 2 Colour GREEN 0 255 From OFF at 0 to BRIGHT a...

Страница 7: ...6 255 10 Turquoise C47 200 26 47 Italian Blue C45 200 72 24 Brilliant Blue B06 255 Bright Blue B28 40 255 Congo B93 145 255 20 Violet V43 80 80 Magenta M56 255 45 10 Pink M63 215 20 150 White 255 OPER...

Страница 8: ...GUIDE MAINTENANCE MAINTENANCE LOG Date Maintenance Undertaken Note A record of all maintenance MUST be kept in the table above indicating what maintenance was undertaken and when This MUST be dated f...

Страница 9: ...tched o via remote control unit Recycle power to light source or switch on via remote control Poor light output on fibre Unit needs cleaning Carefully clean LED Lens with dry cloth Clean fibre common...

Страница 10: ...t 12V DC 2A 24W max Power Consumption 2 5W in colour cycle mode Min Ambient Temperature 10 C Max Ambient Temperature 45 C Led Type RGBW LED Life 50 000 hours in ambient 25 C Power Connection 2 1 x 5 5...