background image

WARNING – Connecting constant current LED fittings to a driver with excessive 
minimum voltage output will result in catastrophic damage to the LED devices 
within these fittings. Always check the minimum output voltage of the driver and 
ensure that based on 3.2V per LED an adequate number of fittings are connected 
prior to powering up the system. 
 
WARNING – Hot swapping constant current LED fittings to a driver may result in 
catastrophic damage to the LED devices within these fittings. Always power down 
the driver before adding a constant current LED fitting. 
 
These LED fittings are IP66 rated and are suitable for use in both indoor/dry areas 
and in damp or wet conditions. 
 

IMPORTANT 

 

THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE 

INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND 

OPERATION OF THE PRODUCT, ITS COMPONENT PARTS AND THE HAZARDS 

INVOLVED. 

 

ELECTRICAL WIRING AND CONNECTION MUST BE CARRIED OUT BY A SUITABLY 

QUALIFIED PERSON OBSERVING ALL LOCAL AND STATUTORY ELECTRICAL 
REGULATIONS.

 

 

LD10 Articulated LED Downlight

Safety Guidelines

LD10 Articulated LED Downlight

Connections

The fittings are suitable for use with a constant current driver only. 
 
• 350mA or 500mA output (depending on territory) 
• Rated Class 2 or LPS  
• Approvals UL/CE 
• Protection - Short Circuit/Over load/ Over voltage 
• Minimum voltage rating not to exceed the number of LED fittings connected 
• Number of LED fittings connected not to exceed the Maximum voltage rating  
 
There are 4 electrical connections required before connecting the system to the 
mains. 
 
1. Connect 

ALL

 LED fittings to the input channels of the Series Splitter. 

2. Make sure 

ALL

 unused Series Splitter channels have continuity link jumpers  

     fitted 
3. Connect the Series Splitter directly to the Constant Current Driver. 
4. Connect the electrical supply to the driver. Switch on power, the LED fittings will 
     illuminate. 
 

If no light is produced, consult the TROUBLESHOOTING section. 

 

2

4

LD10 Articulated LED Downlight

LD10 Fitting Guide

LD10 Articulated LED Downlight

Introduction

Thank you for purchasing these low voltage UFO LED fittings. 
 
Please read these instructions fully before installing your LED fittings, connecting 
your LED fittings to the splitter/driver and before connecting your display system to 
the electrical mains. Please keep this manual for future reference. 
 
The UFO splitters are supplied with removable continuity jumpers. Retain these 
jumpers for future use. 
 
Please refer to the specific section within this manual to ensure correct associated 
splitters/drivers/power supply units are used for your fittings. 
 
These LED fittings are only mains dimmable with an appropriate mains dimmable 
constant current driver. 
 
These LED fittings operate on a constant current driver low voltage supply. 
Constant current and constant voltage LEDs cannot be intermixed on the same 
driver. Please refer to the specific section within this guide for wiring/connection 
guidance. 

 

 
 

 

1

3

LD10 Downlights are constant current LED fittings. 
 
Before assembly, unpack the shipment and check that all components are included 
before commencing your installation. It is recommended that the system be planned 
prior to work commencing to ensure the Series Splitter is centrally located to match 
LED fitting cable lengths. Fit all LD10 fittings in place as detailed below.

NOTES
Don

t cut the hole too big

Take care not to trap wires

LD3 Articulated Fitting

53mm

1.0

Cut hole in 
mounting 
surface

2.0

Thread cable 
through hole

3.0

Fold back 
springs and 
push LED 
Fitting through 
the hole

4.0

Push LED 
Fitting all 
the way in

5.0

Adjust LED 
Fitting to 
required angle

Отзывы: