background image

MODEL

 

VARIATIONS

The UFO IP-02 enclosure is available in two power source variants: 
 

1.

 DC supply (12V or 24V DC) denoted by the model number having the suffix DC. This version 

has the light source DC PSU mounted remotely external to the enclosure and the unit is pow-
ered from the DC supply to a terminal block inside the enclosure. For this version, the PSU can 
be supplied by UFO or the customer. For the USA and Canada, if supplied by the customer the 
PSU must be UL listed and not only suitable in terms of correct voltage and wattage but also 
suitable for the environment/location in which the PSU is to be installed. 
 

2.

 Mains supply (240V 50 Hz) denoted by the model number having the suffix AC. This 

version has the light source 12V or 24V DC PSU mounted inside the enclosure and the unit is 
powered from a mains supply to a fused terminal block inside the enclosure.  
 
Four IP-02 enclosure variants are shown in the examples on the followng pages. 
 
Figures 1 and 2 are schematics of the 24V light source version using a UFO Nova DMX light 
source as an example. For DC supply voltages more than 12V a DC-to-DC converter is used to 
power the 12V DC fan. 
 
Figures 3 and 4 are schematics of the 12V light source version using a UFO Gemini DMX light 
source as an example.

INTRODUCTION

3

UFO

 

LIGHTING

Содержание IP-02

Страница 1: ...PRODUCT USER GUIDE IP 02 Weatherproof Enclosure PLEASE READ THIS USER GUIDE BEFORE INSTALLING OPERATING OR PERFORMING MAINTENANCE ON THE ENCLOSURE Rev C1...

Страница 2: ...person familiar with the construction and operation of the product and the hazards involved When used in the USA or Canada cables connected to this enclosure must be UL listed and not only suitable f...

Страница 3: ...uitable for the environment location in which the PSU is to be installed 2 Mains supply 240V 50 Hz denoted by the model number having the suffix AC This version has the light source 12V or 24V DC PSU...

Страница 4: ...INTRODUCTION FIGURE 1 AC SCHEMATIC USING NOVA LIGHT SOURCE IP 02 WEATHERPROOF ENCLOSURE USER GUIDE 4...

Страница 5: ...INTRODUCTION FIGURE 2 24V DC SCHEMATIC USING NOVA LIGHT SOURCE 5 UFO LIGHTING...

Страница 6: ...INTRODUCTION FIGURE 3 AC SCHEMATIC USING GEMINI LIGHT SOURCE IP 02 WEATHERPROOF ENCLOSURE USER GUIDE 6...

Страница 7: ...INTRODUCTION FIGURE 4 12V DC SCHEMATIC USING GEMINI LIGHT SOURCE 7 UFO LIGHTING...

Страница 8: ...DMX RF Remote 240VAC 50Hz 46W UFO IP02 NOVA CT T R DC Manual DMX RF Remote 24V DC 46W Ordering Code Control Options Power Variant Max Power UFO IP02 GEM SLP CT M AC Manual 240VAC 50Hz 20W UFO IP02 GEM...

Страница 9: ...MIC3000 AC Manual DMX RF Remote 240VAC 50Hz 5Wx2 UFO IP02 MIC3000 DC Manual DMX RF Remote 12V DC 5Wx2 MICROLED 2000 3000 PRODUCT CODES Ordering Code Control Options Power Variant Max Power UFO IP02 V...

Страница 10: ...V DC 18W UFO IP02 VEGA CT X T M AC Manual Dim 240VAC 50Hz 18W UFO IP02 VEGA CT X T M DC Manual Dim 24V DC 18W UFO IP02 VEGA CT X C DMX AC DMX 240VAC 50Hz 18W UFO IP02 VEGA CT X C DMX DC DMX 24V DC 18W...

Страница 11: ...TING DIMENSIONS Note that dimensions are shown in mm Ordering Code Control Options Power Variant Max Power UFO IP02 MIC5000T AC DMX Manual 240VAC 50Hz 5W UFO IP02 MIC5000T DC DMX Manual 12V DC 5W MICR...

Страница 12: ...rientation detailed below The enclosure must be located out of direct sunlight and there must be a minimum of 300mm 12 of space around all sides to allow for air circulation and to prevent overheating...

Страница 13: ...ote that unless UFO are installing the unit then we do not supply fixings This is due to the large variance of surface types the enclosure may be mounted to 4 Follow the instructions for the chosen fi...

Страница 14: ...re tightening the gland to create a seal Do not overtighten the nylon gland Never run the luminaire with the fibre optic harness out of the aperture Loosen the gland for the DMX or 0 10V cables and fe...

Страница 15: ...cables and feed the cables carefully through the gland leaving sufficient slack inside the enclosure to reach the back of the light source Tighten the gland and fit RJ45 or XLR connectors to the cabl...

Страница 16: ...on PSU is lit Light source not connected correctly Refer to Troubleshooting section in light source user guide Light source not set up correctly Refer to Operation section in light source user guide...

Страница 17: ...orrect mounting Port Connector Size 30mm Fibre Type Glass or PMMA Material Finish Sheet Steel RAL7035 Overall Dimensions 400mm x 300mm x 210mm 15 7 x 11 8 x 8 3 Protection Category IP55 Min Ambient Te...

Страница 18: ...18 IP 02 WEATHERPROOF ENCLOSURE USER GUIDE NOTES...

Страница 19: ...19 UFO LIGHTING NOTES...

Страница 20: ...bH Andreasstra e 20 93059 Regensburg Deutschland 49 0 9491 955880 www ufo licht de Universal Fiber Optics USA LLC 1749 Northgate Blvd Sarasota FL34234 USA 941 343 8115 www fiberopticlighting com Unive...

Отзывы: