Refrigerant Leak Detector

INSTRUCTION MANUAL

RLD15B

 Limited Warranty

 The 

RLD15B

 is warranted to be free from defects 

in materials and workmanship for a period of two years 

from the date of purchase. If within the warranty period 

your instrument should become inoperative from such 

defects, the unit will be repaired or replaced at UEi’s 

option. This warranty covers normal use and does not 

cover damage which occurs in shipment or failure 

which results from alteration, tampering, accident, 

misuse, abuse, neglect or improper maintenance. 

Batteries and consequential damage resulting from 

failed batteries are not covered by warranty. 

       

 

Any implied warranties, including but not limited 

to implied warranties of merchantability and fitness 

for a particular purpose, are limited to the express 

warranty. UEi shall not be liable for loss of use of the 

instrument or other incidental or consequential dam-

ages, expenses, or economic loss, or for any claim or 

claims for such damage, expenses or economic loss. 

 

A purchase receipt or other proof of original 

purchase date will be required before warranty repairs 

will be rendered. Instruments out of warranty will be 

repaired (when repairable) for a service charge. 

For more information on warranty and service:

www.ueitest.com • Email: [email protected]

1-800-547-5740 • FAX: (503) 643-6322

This warranty gives you specific legal rights. You may 

also have other rights which vary from state to state.

Copyright © 2021 Kane USA Inc. All rights reserved.          17203

RLD15B

 

Refrigerant Leak Detector

INTRODUCTION

The RLD15B features a solid electrolyte semicon-

ductor sensor that is designed to detect the more 

current and difficult HFC refrigerants such as 

R134a, R1234yf, R410A, R404A, R407C, in addition to 

all HCFC (R22) and CFC (R12) refrigerants includ-

ing SNAP approved hydrocarbon blends.

Getting Started

Low Bat.

Lo  Norm. Hi

8

Mute Sens.

1. 

TURN ON: 

 Press 

  Power Button

Low Bat.

Lo  Norm. Hi

0

Mute Sens.

2. 

WARM UP: 

  Allow 20 sec.

  to warm up

 

(Indicator will blink  

  and alarm will beep)

Lo  Norm. Hi

3. 

READY: 

 

When the flashing  

  “0” stops and the  

  green sensitivity    

  indicator LED     

  turns on

4. 

The leak detector response to changes in 

  refrigerant concentration. When detection  

 

  occurs, move the probe away from the source   

  and back again to confirm the leak source. The  

  detector alarm will reset if the probe is held    

  fixed at the source.

Leak Size Indicator

 

 

  The digital leak size indicator remains off 

until a leak is detected. A number from 1 - 9 will 

be displayed for all HFC and HCFC refrigerants,  

regardless of the sensitivity settings. 

  The number will increase or decrease  

depending on the amount of refrigerant sensed. 

The maximum value will be displayed once the 

leak source has been located.  

Audio Mute Function

Maximum # Displayed

1-3

4-6

7-9

Leak Size (oz/yr)

< 0.1

0.1 - 0.5

> 0.5

FEATURES

Mute Sens.

1.  Press Mute   

  button to  

  Mute speaker.

Approximate Size Indications

Low Bat.

Lo  Norm. Hi

8

Mute

Sens.

Work light

1.  Press 

 

  button to  

  turn work light.

Sensitivity Level

Mute Sens.

1.  Press Sens.

  button to  

  Change / Scroll 

 Sensitivity 

  Levels.  

 (Indicated 

  By LED)

Lo  Norm. Hi

Low Battery Indicator

 

Replace batteries when flashing

Low Bat.

Lo  Norm. Hi

8

Mute Sens.

  Battery replacement:

  1. Remove battery cover on end of

    instrument. (Fig1)

  2. Replace 4 (AA) batteries with correct  

  polarity.

   

(Fig1)

AA

AA

AA

AA