background image

M a i n t e n a n c e

Service

WARNING!

Repair and service of this instrument is to be performed by qualified
personnel only. Improper repair or service could result in physical
degradation of the meter. This could alter the protection from electrical
shock and personal injury this meter provides to the operator. Perform
only those maintenance tasks that you are qualified to do.

These guidelines will help you attain long and reliable service from 
your instrument:

1. Keep your meter dry. If it gets wet, wipe it dry immediately.

2.  Whenever pra c t i cal, keep the instrument away from dust and   

dirt, which can cause premature wear and collect on 
internal components.

3.  Although your instrument is built to withstand the rigors of daily use,  

it can be damaged by severe impacts. Use reasonable caution when
using and storing the instrument.

Cleaning and Decontamination

Periodically clean your meter’s case using a damp cloth. 

DO NOT

use

abrasives, cleaning solvents or strong detergents, as they may damage
the finish or affect the reliability of the structural components.

Probe tips can be cleaned with an abrasive, adequate to remove 
build-up, to ensure good electrical contact.

DANGER!

DO NOT

submerge this instrument in liquid! Liquids may enter this

instrument during cleaning and leak out in subsequent use, exposing
the user to dangerous voltage during measurement.

Repair

This unit contains no user serviceable parts. In the event your 
instrument is physically damaged or does not function properly, 
please return the instrument to UEi following the warranty and 
service instructions.

S p e c i f i c a t i o n s

Operating range

ECT600A-MAN    

P. 3

Vo l t a g e

12 to 600 Volts DC or AC (at 50 - 60 Hz)
M aximum voltage input 700 V DC or AC (ground to phase)
Single probe sensitivity = 100 - 700 V AC (audio only)

C o n t i n u i ty

Audio tone from 0 to 900 K

Ω

(Requires changed instrument)
Output to unit under test: Approximately 2 µA at 1.5 V DC
Charging time: =/>5 sec @ =/> 100 and =/< 700 V AC
Recommended time between charges: 30 min @ no-load
Continuos operation time between charges: 60 + sec*

* O p e rating time is dependent upon time since last charge

O p e rating tempera t u r e

14 - 131˚F (-10 - 55˚C) @ =/<85% RH

and humidity
Power consumption

< 250 mA (Continuos)

D i s p l a y

Ve r t i cal panel of light emmiting diode LED s

Size (excluding 

2 - 1/6” (W) x 9-1/8” (H) x 1-3/4” (D)

detachable test lead)

( 53 mm x 230 mm x 45 mm)

We i g h t

.46 lbs. (210 Gra m s )

Power supply

Rechargeable capacitor - draws power from source tested

A c c u ra cy

This instrument is not intended for precise measurement
L ED indicators will light when voltage approaches an
i n d i cated value, and remain lit when higher voltage is 
a p p l i e d

* 2 40 / 2 08 volt cross sensitivity: The 240 volt LED begins to
illuminate at about 210 volts - Although some 208 volt
s o u rces may illuminate the 240 volt LED, it typically does
not fully illuminate until it reaches approximately 215 volts.

R e s p o n s e

1 sec. max i m u m

Protection class

IP 50

Over-voltage ca t e g o ry

CAT III, 700 volts to ground

Pollution degree

2

C a l i b ration cy c l e

Annual certification is recommended

Содержание ECT600A

Страница 1: ...1 800 547 5740 Fax 503 643 6322 www ueitest com email info ueitest com ECT600A INSTRUCTION MANUAL ...

Страница 2: ...provides a quick and sure display of measured voltage ranging from 12 to 600 volts AC or DC A loud clear audio tone sounds to give you a quick indication that voltage or continuity is present even if you can t see the display The continuity feature sounds at a distinctive tone when the ECT600A finds a path for current to flow between two wires or other probed points With no batteries to replace yo...

Страница 3: ...the unit exposed to a voltage source 100 to 700 volts for at least 5 seconds Typically the instrument will retain its charge for at least 30 minutes without being used and will sustain the continuity tone for more than one minute if recently charged Charging is required for all audio tone dependent functions Testing For Continuity Continuityindicates that current can flow from one point to another...

Страница 4: ...ble parts In the event your instrument is physically damaged or does not function properly please return the instrument to UEi following the warranty and service instructions Specifications Operating range ECT600A MAN P 3 Voltage 12 to 600 Volts DC or AC at 50 60 Hz Maximum voltage input 700 V DC or AC ground to phase Single probe sensitivity 100 700 V AC audio only Continuity Audio tone from 0 to...

Страница 5: ...d to implied warranties of merchantability and fitness for a particular purpose are limited to the express warranty UEi shall not be liable for loss of use of the instrument or other incidental or consequential damages expenses or economic loss or for any claim or claims for such damage expenses or economic loss A purchase receipt or other proof of original purchase date will be required before wa...

Отзывы: