Battery Replacement

Always use a fresh replacement battery of the specified size and type.
Immediately remove the old or weak battery from the meter and 
dispose of it in accordance with your local disposal regulations. Old or
defective batteries can leak chemicals that corrode electronic circuits.

WARNING!

To avoid electric shock, be sure to turn off the meter’s power and 
disconnect test leads from any equipment before you remove 
or install batteries.

To install a new battery, follow these procedures:

1. Remove the cover on back of instrument.

2.  Replace button battery observing correct polarity.

3.  Replace battery cover.

WARNING!

Under 

NO

circumstance should you expose batteries to extreme heat or

fire as they may explode and cause injury.

NOTE:

If you do not plan to use the meter for a month or more,

remove the battery and store it in an area that won’t be damaged by a
leaking battery.

S p e c i f i c a t i o n s

Temperature Range

-40˚ to 300˚F (-40˚ to 150˚C)

Accuracy

-40˚ to 50˚F: ±4˚F
+51˚ to 230˚F: ±2˚F
+231˚ to 300F: ±4˚F
-40˚ to 10˚C: ±2˚C
+11˚ to 110˚C: ±1˚C
+111˚ to 149˚C: ±2˚C

Resolution

0.1˚

Gerneral

Display

3.5 digit LCD, 0.435” high numerals

Operating Temperature

32˚ to 122˚F (0˚ to 50˚C)

Operating Humidity

80% max RH

Power Supply

1.5V button battery

Dimensions

1.5” (W) x 7” (H) x 5/8” (D)

Includes

Carrying case, battery, temperature
probe attached to meter and 
instructions.

Recall of MIN/MAX Temperature

1. Depress the “

MIN

” or “

M AX

” push-buttons at any time during the 

measurement sequence.

2. The “

MIN

” or “

M AX

” temperature will be displayed on the LCD for 

approximately five seconds before before switching back to 
normal mode.

MIN/MAX Reset Procedure

1. Depress the “MIN” and “MAX” push-buttons at the same time.

2. Hold the buttons down for five seconds

3. Release both buttons at the same time.

M a i n t e n a n c e

Periodic service

WARNING!

Repair and service of this instrument is to be performed by qualified
personnel only. Improper repair or service could result in physical
degradation of the meter. This could alter the protection from 
electrical shock and personal injury this meter provides to the 
operator. Perform only those maintenance tasks that you are
qualified to do.

These guidelines will help you attain long and reliable service from 
your meter:

1. Calibrate your meter annually to ensure it meets original 

performance specifications.

2.  Keep your meter dry. If it gets wet, wipe it dry immediately. Liquids 

damage electronic circuits.

3.  Whenever pra c t i cal, keep the meter away from dust and dirt, which 

can cause premature wear.

4.  Although your meter is built to withstand the rigors of daily use, it 

can be damaged by severe impacts. Use reasonable caution when
using and storing the meter.

NOTE:

When servicing the meter, use only the replacement parts specified.

Battery: 9V, NEDA 1604 or IEC 6LR 61
Test lead set: ATL55

Cleaning and Decontamination

Periodically clean your meter’s case using a damp cloth. 

DO NOT

use

abrasives, cleaning solvents or strong detergents, as they may damage
the finish or affect the reliability of the structural components.

DT10K-MAN    

P. 2