IMPORTANT SAFETY WARNINGS

 

 

WARNING

Read entire Safety Notes section regarding potential hazard and proper instructions before using this meter. In this 

manual the word “

WARNING

” is used to indicate conditions or actions that may pose physical hazards to the user. The 

word “

CAUTION

” is used to indicate conditions or actions that may damage this instrument. 

 

 

WARNING

To ensure safe operation and service of the tester, follow these instructions. Failure to observe these warnings can 

result in severe injury or death.

 

 

WARNING

•  Before each use, verify meter operation by measuring a known voltage or current.
•  Never use the meter on a circuit with voltages that exceed the category based rating of this meter. 
•  Do not use this meter during electrical storms or in wet weather.
•  Do not use the meter or test leads if they appear damaged. 
•  Ensure meter leads are fully seated and keep fingers away from the metal probe contact when making 

measurements. Always grip the leads behind the finger guards molded into the probe.

•  Do not open the meter to replace batteries while the probes are connected. 
•  Use caution when working with voltages above 60 DC or 25 AC RMS. Such voltages pose shock hazards.
•  To avoid false readings that can lead to electrical shock, replace batteries if a low battery indicator appears. 
•  Unless measuring voltage or current, shut off and lockout power before measuring resistance or capacitance.
• Always adhere to national and local safety codes. Use proper personal protective equipment (PPE) to prevent shock 

and arc blast injury where hazardous live conductors are exposed.

•  Always turn off power to a circuit or assembly under test before cutting, unsoldering or breaking the current path. 

Even small amounts of current can be dangerous.

•  Always disconnect the live test lead before disconnecting the common test lead from the circuit.
•  In the event of electrical shock, ALWAYS bring the victim to the emergency room for evaluation, regardless of 

victim’s apparent recovery. Electrical shock can cause unstable heart rhythms that may need medical attention.

•  If any of the following occur during testing, turn off the power source to the circuit being tested: arching, flame, 

smoke, extreme heat, smell of burning materials or discoloration or melting of components. 

 

 

WARNING

Higher voltages and currents require greater awareness of physical safety hazards. Before connecting the test leads; 

turn off power to the circuit under test, set meter to the desired function and range; connect the test leads to the meter 

first, then connect to the circuit under test. Reapply power. If an erroneous reading is observed, disconnect power 

immediately and recheck all settings and connections. 

 

 

WARNING

This meter is designed for trade professionals who are familiar with the hazards of their trade. Observe all 

recommended safety procedures that include proper lockout utilization and use of personal protective equipment that 

includes safety glasses, gloves and flame resistant clothing.

CLEANING

Periodically clean your meters’ case using a damp cloth. DO NOT use abrasive, flammable liquids, cleaning solvents, or strong 

detergents as they may damage the finish, impair safety, or affect the reliability of the structural components.

Содержание DM515

Страница 1: ...A MAX FUSED MAX CAT III 600V CAT II 1000V DM515 F C INSTRUCTION MANUAL ENGLISH DM515 True RMS 1000V Digital Multimeter w Temperature 1000V CAT II 600V CAT III 99 Washington Street Melrose MA 02176 Pho...

Страница 2: ...LEANING 4 OVERVIEW 5 SYMBOLS 6 OPERATING INSTRUCTIONS AC DC Voltage 1000V AC DC 6 Resistance 40M 7 Continuity 7 Diode 8 Capacitance 8 AC DC Microamps 6000 A 9 AC DC Milliamps 400mA 9 AC DC Amps 10A 10...

Страница 3: ...t 2000m Display 6 000 Backlight Yes Over range OL is displayed Dimensions 6 49 x 3 3 x 2 17 Item Weight 15 0 oz Calibration Recommended annually CAT Rating CAT III 600V CAT II 1000V Certifications cEL...

Страница 4: ...t shock and arc blast injury where hazardous live conductors are exposed Always turn off power to a circuit or assembly under test before cutting unsoldering or breaking the current path Even small am...

Страница 5: ...Press and hold to return to live readings E Select Button Press to select AC DC or Auto Selection in the following functions Voltage A mA Amps Press to select C or F in the Temperature function F Func...

Страница 6: ...lts DC RMS at either the common or multifunction input ports as measured from earth ground Features RANGE MIN MAX HOLD SEL RANGE SEL Temp A True RMS MIN MAX HOLD FAST V Apo A mA A A mA 10A MAX FUSED 4...

Страница 7: ...load Protection Approx 1 0V Approx 40 600V Features MIN MAX HOLD Buzzer sounds at less than 40 WARNING Do not measure resistance on a live circuit Continuity RANGE SEL Temp A True RMS MIN MAX HOLD FAS...

Страница 8: ...IN MAX HOLD FAST V Apo A mA A A mA 10A MAX FUSED 400mA MAX FUSED MAX CAT III 600V CAT II 1000V DM515 F C A A mA F C Apo DM515 V Forward Bias Displays approx voltage drop RANGE SEL Temp A True RMS MIN...

Страница 9: ...Accuracy Resolution Overload Protection 60mA to 400mA 1 2 5 dgts 0 01mA to 0 1mA 600mA 1000V Fast Fuse Minimum sensitivity 5mA AC auto selection mode only DCmA Ranges Accuracy Resolution Overload Prot...

Страница 10: ...to selection mode only CAUTION 20A overload for 30 seconds max F Ranges Accuracy Resolution Overload Protection 328 to 999 F 1 5 3 6 F 0 1 F 600V 1000 to 2462 F 1 5 3 0 F 1 F C Ranges Accuracy Resolut...

Страница 11: ...low testing on recessed conductors such as standard wall outlets Take care not to lose the shields WARNING Test lead category protections apply only to test leads and should not be confused with the m...

Страница 12: ...ding the limits mentioned in the General Specifications section allow the instrument to return to normal operating conditions before using it Copyright 2018 Kane USA Inc All Rights Reserved 17489 0118...

Отзывы: