9
Features:
RANGE
MIN/MAX
HOLD
SEL
ACµA
Ranges
Accuracy
Resolution
Overload Protection
600µA to 6000µA
±(1.2% +5 dgts)
0.1µA to 1µA
600mA /1000V Fast Fuse
Minimum sensitivity: 50µA AC (auto selection mode only)
DCµA
Ranges
Accuracy
Resolution
Overload Protection
600µA to 6000µA
±(1.0% +3 dgts)
0.1µA to 1µA
600mA /1000V Fast Fuse
Minimum sensitivity: 50µA DC (auto selection mode only)
ACmA
Ranges
Accuracy
Resolution
Overload Protection
60mA to 400mA
±(1.2% +5 dgts)
0.01mA to 0.1mA
600mA /1000V Fast Fuse
Minimum sensitivity: 5mA AC (auto selection mode only)
DCmA
Ranges
Accuracy
Resolution
Overload Protection
60mA to 400mA
±(1.0% +3 dgts)
0.01mA to 0.1mA
600mA /1000V Fast Fuse
Minimum sensitivity: 5mA DC (auto selection mode only)
AC/DC Microamps: 6000µA
AC/DC Milliamps: 400mA
RANGE
SEL
MIN/MAX
HOLD
FAST
V
Apo
A
µA
mAµA
A
mA
10A
MAX
FUSED
400mA
MAX
FUSED
MAX
CAT III
600V
CAT II
1000V
DM505
A
µA
mA
µA
Apo
AT
DM505
µ A
RANGE
SEL
MIN/MAX
HOLD
FAST
V
Apo
A
µA
mAµA
A
mA
10A
MAX
FUSED
400mA
MAX
FUSED
MAX
CAT III
600V
CAT II
1000V
DM505
A
µA
mA
mA
Apo
AT
DM505
A
m