Cleaning

Periodically clean your meter’s case using a damp cloth. 

DO NOT

use

abrasive, flammable liquids, cleaning solvents, or strong detergents as
they may damage the finish, impair safety, or affect the reliability of the
structural components.

Battery, Fuse and Test Load Replacement

Always use a fresh replacement battery of the specified size and type.
Immediately remove the old or weak battery from the meter and 
dispose of it in accordance with your local disposal regulations. Batteries
can leak chemicals that corrode electronic circuits. If your meter is not
going to be used for a month or more, remove and store the battery in
a place that will not allow leakage to damage other materials. This
meter uses a single standard 9V battery (NEDA 1604, JIS006P, IEC 6F
22), a 1000V/440 mA IR 10 kA fast acting F fuse for mAµA current input,
and a 1000V/11A IR 10 Ka fast acting F fuse for A current input

WARNING!

Disconnect the test leads from the circuit under test and from the meter
prior to removing or installing batteries.

To install a new battery, follow these procedures:

1. Turn off the meter.

2.  Remove the rubber boot from the meter, starting at the top.

3.  Place meter face down on a clean cloth.

4.  Remove the screws from the rear case. Two machined screws 

fasten the bottom and two self-tapping screws fasten the top.

5.  Separate the two halves to expose the battery.

6.  Remove and discard the old battery. Always dispose of old batteries 

promptly in a manner with local disposal regulations.

WARNING!

Under no circumstances should you expose batteries to extreme heat or
fire as they may expose and cause injury.

7. Place a fresh 9V battery in the battery clip.

8.  Reassemble the meter.

Tro u b l e s h o o t i n g

If the meter fails to operate even with the battery or fuse replacements,
check twice according to operating procedures as described in this manual.

If the meter’s V/  input terminal was subjected to high voltage tra n s i e n t
( caused by lightning or switching surge to the system) by accident or
abnormal operating conditions, the series  fusible resistors will be blown in
order to protect the user and the meter. Most measuring functions through
this terminal will then be open circuit.

In this case, the series fusible resistors and the spark gaps should be
replaced by qualified personnel. Refer to the 

L IMITED WA RRA NTY &

L IMITATIONS OF L I A BIL ITY

section for obtaining warra n ty or 

repairing serv i c e .

DM391/393-MAN    

P. 6

Tips for Measuring Current

• When measuring a 3-phase system, special attention should be taken 

to the phase to phase voltage which is significantly higher than the 
phase to earth voltage. To avoid exceeding the voltage rating of the 
protection fuse(s) accidentally, always consider the phase to phase 
voltage as the working voltage for the protection fuse(s).

• When measuring current, the meter’s internal shunt resistors 

develop a voltage across the meter’s terminals called “burden 
voltage”. This voltage drop may affect precision circuit 
or measurements.

Auto/Manual Range Operation

Press the “

RANGE

” push-button momentarily to select manual-ranging

in volts, ohms, and current measurement functions, and the meter will
remain in the range it was in, when the LCD annunciator “

AUTO

turns off.

Press the button momentarily again to step through the ranges.
Press and hold the “

RANGE

” push-button for 2 seconds to resume 

auto-ranging.

Note:

M a n u a l - ra n ging feature is not available in Hz (Duty), CAP, TEMP,     

and        functions.

Auto Power-Off

The Auto-Power-Off feature automatically turns the meter off to extend
battery life after approximately 30 minutes of no activities. To turn on
the meter after Auto-Power-Off, turn the rotary switch from OFF to any
function (ON).

M a i n t e n a n c e

Periodic Service

WARNING!

Repair and service of this instrument is to be performed by qualified
personnel only. Improper repair or service could result in physical
degradation of the meter. This could alter the protection from 
electrical shock and personal injury this meter provides to the 
operator. Perform only those maintenance tasks that you are
qualified to do.

These guidelines will help you attain long and reliable service from 
your meter:

• Calibrate your meter annually to ensure it meets original 

performance specifications

• Keep your meter dry. If it gets wet, wipe dry immediately.

Liquids can degrade electronic circuits

• Whenever practical, keep the meter away from dust and 

dirt that can cause premature wear

• Although your meter is built to withstand the rigors of daily 

use, it can be damaged by severe impacts. Use reasonable 
caution when using and storing the meter

Содержание DM391

Страница 1: ...1 800 547 5740 Fax 503 643 6322 www ueitest com email info ueitest com DM391 393 INSTRUCTION MANUAL...

Страница 2: ...user to serious or possibly fatal injury Voltages above 60 volts DC or 25 volts AC may constitute a serious shock hazard Always turn off power to a circuit or assembly under test before cutting unsold...

Страница 3: ...Press the HOLD push button for two seconds to turn the backlight ON or OFF when the HOLD function is simultaneously activated with the D H symbol on the display Press the HOLD push button momentarily...

Страница 4: ...0 V DC or AC RMS Resistance Measurement Ohms Diode and Continuity DM391 393 MAN P 3 WARNING To avoid damaging the meter or the equipment under test remove all power from the circuit and discharge all...

Страница 5: ...or current signal by counting the number of times the signal crosses a threshold level each second To measure the frequency of a voltage or current signal press the Hz Duty push button momentarily wh...

Страница 6: ...current Use the proper terminals functions and range for current measurements Never place the probes in parallel with any circuit or component when the test leads are plugged into the current termina...

Страница 7: ...n circuit In this case the series fusible resistors and the spark gaps should be replaced by qualified personnel Refer to the LIMITED WARRANTY LIMITATIONS OF LIABILITY section for obtaining warranty o...

Страница 8: ...temperature 32 to 104 F 0 to 40 C Storage temperature 4 to 140 F 20 to 60 C Temperature coefficient Nominal 0 15 x specified accuracy C 0 to 8 C or 28 to 40 C or otherwise specified Relative humidity...

Страница 9: ...400mA 100 A 4A 1mA 10A 10mA 1 5 10 1 5 10 2 0 10 Range Resolution Accuracy DM391 DM393 400 0 1 1 0 5 1 0 5 4000 1 40k 10 400k 100 0 5 3 0 5 3 4M 1k 1 0 5 1 0 5 10M 10k 1 5 10 1 5 10 Audible threshold...

Страница 10: ...taneous peak value to the True RMS value which is commonly used to define the dynamic range of a True DMM A pure sinusoidal waveform has a Crest Factor of 1 414 A badly distorted sinusoidal waveform n...

Страница 11: ...ited to implied warranties of merchantability and fitness for a particular purpose are limited to the express warranty UEi shall not be liable for loss of use of the instrument or other incidental or...

Отзывы: