background image

FEATURES

•  CO reading direct on your device
•  Reads CO up to 999 ppm
•  Detects CO to 1 ppm
•  Use with compatible iOS

®

 or Android™ smart devices

•  Free App displays 3 visual danger levels
•  App allows logging and emailing capabilities
•  Low Battery Indicator

GENERAL SPECIFICATIONS

•  Operating Temperature: 

32˚ to 104˚F (0˚ to 40˚C)

•  Dimensions: 

2.4 x 1.17 x 1.02” (61 x 30 x 26mm)

•  Item Weight:  

0.05oz

•  Battery Type:  

CR2032 

•  Accuracy: 

± (3% + 1 ppm)

•   App Compatibility:

  iOS

®

; iPhone 4X and up running iOS7 and higher iPhone 7  

 

   

(requires use of Lightning to 3.5mm headphone jack adapter)

   

Android™; Galaxy S4, Nexus 5, HTC One running Android 4.4 or higher

NOTE: 

Requires compatible mobile device and FREE downloadable App “

CoChecker

”.

SYMBOLS

Hold/Capture Value

Maximum measured value 

displayed

Warning or Caution

IMPORTANT SAFETY  WARNINGS

WARNING 

 

Read entire Safety Notes section regarding potential hazard and proper instructions before 

using this tester. In this manual the word “

WARNING

” is used to indicate conditions 

or actions that may pose physical hazards to the user. The word “

CAUTION

” is used to 

indicate conditions or actions that may damage this instrument. 

WARNING 

 

•  To ensure safe operation and service of the tester, follow these instructions. Failure to  

  observe these warnings can result in severe injury or death.
•  This meter is designed for trade professionals who are familiar with the hazards of their  

  trade. Observe all recommended safety procedures that include use of personal protective  

 equipment.
• Carbon monoxide is life threatening even at relatively low concentrations. Be sure you  

  understand the risks before investigating potential leaks.
•  Do not use the tester if it appears damaged. 
•  Always adhere to national and local safety codes. 
•  This COA1 is specified to read Carbon Monoxide from 1-999ppm. The app may continue  

  to read above this threshold. Professional safety precautions are recommended above  

 35ppm. 
•  Threshold safety levels are set to industry standards. By customizing these levels to  

  higher COppm thresholds, users risk personal safety. These setting are saved and used  

  after exiting and relaunching the App. To reset back to industry standards set the    

  levels to: Green ≤ 

10

 Orange ≤ 

35

 Red.

CAUTION 

 

•  The COA1 is designed for ambient testing only. DO NOT place the instrument in flue gas  

  or warm air streams. 
•  The COA1 is not designed for in-flue detection. Readings more than 999 ppm will damage  

  the sensor in the COA1, even if readings continue above the 999ppm range.
•  Ensure that the sensor vent at the top of the instrument is free from obstruction.
•  When zeroing the COA1, the adapter should be in fresh air. The COA1 uses an  

 

  electrochemical sensor, which are subject to long-term drift pending use and CO levels  

  during use. Calibration services are available at UEi Recertification Centers. Call or visit  

  us online for more information.

NOTE: 

A quick instrument check can be performed by the smoke from a blown out match. Let 

smoke enter the 

vent

. This will cause the indicated CO level to increase.

Содержание COA1

Страница 1: ... the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particula...

Страница 2: ...all recommended safety procedures that include use of personal protective equipment Carbon monoxide is life threatening even at relatively low concentrations Be sure you understand the risks before investigating potential leaks Do not use the tester if it appears damaged Always adhere to national and local safety codes This COA1 is specified to read Carbon Monoxide from 1 999ppm The app may contin...

Страница 3: ...aph in JPEG Highlight the Log to be exported Touch the MAIL button to enter the recipient email address B Settings Touch the SETTINGS button to change settings Refresh rate Continuous recording Max Samples and Logging Interval C Viewing Measurements You can easily view measurements on your mobile device D Hold Touch the HOLD button to hold the reading on the screen E Record Touch the RECORD button...

Страница 4: ...ns exceeding the limits mentioned in the General Specifications section allow the instrument to return to normal operating conditions before using it WARRANTY The COA1 is warranted to be free from defects in materials and workmanship for a period of one year from the date of purchase If within the warranty period your instrument should become inoperative from such defects the unit will be repaired...

Отзывы: