INTRODUCTION

The CD100A Combustible Gas Leak Detector is capable of sensing many 
combustible, non-combustible and toxic gases that include but are not 
limited to the following:

Acetone

Industrial 

Solvents

Alcohol

Jet 

Fuel

Ammonia

Lacquer 

Thinners

Benzene

Methane

Butane

Naphtha

Ethylene Oxide 

Natural Gas

Gasoline-Petrol

Propane

Halon

Refrigerants

Hydrogen 

Sulfide

Toluene

NOTE: 

This leak detector is factory calibrated for methane in air.

WARNING! 

This unit should not be used for detection of 

Carbon Monoxide.

Features include

• Fully adjustable steady tic rate accelerates as the sensor tip 

 approaches a leak (the adjustment knob is located on the side of the unit)

• “Tip-Light” in sensor cover used to see around the area of leak in a 

dark environment

• Long 18” flexible gooseneck
• Audible and visual leak indicator
• Low battery indicator and separate battery compartment for 

easy replacement

• Power On light
• Solid state semiconductor sensor provides instantaneous detection
• Sensor cover to protect sensor
• Ruggedized protective rubber boot
• Socket for optional earphone

Содержание CD100A-N

Страница 1: ...INSTRUCTION MANUAL ENGLISH CD100A Combustible Gas Leak Detector 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com...

Страница 2: ...age this instrument WARNING Charging or discharging batteries may give off an explosive gas Keep away from open flame and sources of ignition from the battery at all times Safety Tips Introduction Int...

Страница 3: ...ne in air WARNING This unit should not be used for detection of Carbon Monoxide Features include Fully adjustable steady tic rate accelerates as the sensor tip approaches a leak the adjustment knob is...

Страница 4: ...C Fuse Not Applicable to Identified Model Battery Senses leading combustible non combustible and toxic gases Minimum detection 50 ppm methane Long 18 gooseneck for hard to reach areas Tip light in sen...

Страница 5: ...tic increases in volume when exposed to gases with 50 parts per million or more When gas is detected the tic rate will increase rotate the thumbwheel back to the steady tic resetting the instrument t...

Страница 6: ...affecting instrument operation 6 Realign the LED ensuring it sits above the sensor 7 Replace the sensor cover by pushing it firmly in place Power supply 1 x 9V battery Sensor Solid state semi conduct...

Страница 7: ...in use that pre date this directive and may emit electromagnetic radiation in excess of the standards defined in the directive it may be appropriate to check the analyzer prior to use The following p...

Страница 8: ...urchase date will be required before warranty repairs will be rendered Instruments out of warranty will be repaired when repairable for a service charge Return the unit postage paid and insured to Thi...