option M423 & M513 Junction Boxes

M423

Not UL or cUL approved.

M513

Does not meet ATEX or Enclosure Type 

4X requirements.

RECOMMENDED PRACTICES AND WARNINGS 

United  Electric  Controls  Company  recommends  careful  consideration  of  the  fol-
lowing factors when specifying and installing UE pressure and temperature units. 
Before  installing  a  unit,  the  Installation  and  Maintenance  instructions  provided 
with unit must be read and understood. 

•  To avoid damaging unit, proof pressure and maximum temperature limits stated 

in literature and on nameplates must never be exceeded, even by surges in the 
system. Operation of the unit up to maximum pressure or temperature is accept-
able on a limited basis (e.g., start-up, testing) but continuous operation must be 
restricted  to  the  designated  adjustable  range.  Excessive  cycling  at  maximum 
pressure or temperature limits could reduce sensor life.

•  A back-up unit is necessary for applications where damage to a primary unit 

could endanger life, limb or property. A high or low limit switch is necessary 
for applications where a dangerous runaway condition could result.

•  The adjustable range must be selected so that incorrect, inadvertent or mali-

cious setting at any range point cannot result in an unsafe system condition.  

•  Install unit where shock, vibration and ambient temperature fluctuations will 

not  damage  unit  or  affect  operation.  When  applicable,  orient  unit  so  that 
moisture  does  not  enter  the  enclosure  via  the  electrical  connection.  When 
appropriate, this entry point should be sealed to prevent moisture entry.

•  Unit must not be altered or modified after shipment. Consult UE if modifica-

tion is necessary.  

•  Monitor operation to observe warning signs of possible damage to unit, such 

as drift in set point or faulty display.  Check unit immediately.

•  Preventative maintenance and periodic testing is necessary for critical appli-

cations where damage could endanger property or personnel.

•  Electrical ratings stated in literature and on nameplate must not be exceed-

ed.  Overload  on  a  switch  can  cause  damage,  even  on  the  first  cycle.    Wire 
unit according to local and national electrical codes, using wire size recom-
mended in installation sheet.

•  Do not mount unit in ambient temp. exceeding published limits.

LIMITED WARRANTY

Seller  warrants  that  the  product  hereby  purchased  is,  upon  delivery,  free  from 
defects in material and workmanship and that any such product which is found to 
be defective in such workmanship or material will be repaired or replaced by Seller 
(Ex-works,  Factory,  Watertown,  Massachusetts.  INCOTERMS);  provided,  however, 
that  this  warranty  applies  only  to  equipment  found  to  be  so  defective  within  a 
period of 36 months from the date of manufacture by the Seller. Seller shall not 
be obligated under this warranty for alleged defects which examination discloses 
are  due  to  tampering,  misuse,  neglect,  improper  storage,  and  in  any  case  where 
products are disassembled by anyone other than authorized Seller’s representatives. 
EXCEPT  FOR  THE  LIMITED  WARRANTY  OF  REPAIR  AND  REPLACEMENT  STATED 
ABOVE,  SELLER  DISCLAIMS  ALL  WARRANTIES  WHATSOEVER  WITH  RESPECT  TO 
THE  PRODUCT,  INCLUDING  ALL  IMPLIED  WARRANTIES  OF  MERCHANTABILITY 
OR FITNESS FOR ANY PARTICULAR PURPOSE.

LIMITATION OF SELLER’S LIABILITY

SELLER’S  LIABILITY  TO  BUYER  FOR  ANY  LOSS  OR  CLAIM,  INCLUDING  LIABILITY 
INCURRED  IN  CONNECTION  WITH  (I)  BREACH  OF  ANY  WARRANTY  WHATSO-
EVER, EXPRESSED OR IMPLIED, (II) A BREACH OF CONTRACT, (III) A NEGLIGENT 
ACT OR ACTS (OR NEGLIGENT FAILURE TO ACT) COMMITTED BY SELLER, OR (IV) 
AN  ACT  FOR  WHICH  STRICT  LIABILITY  WILL  BE  INPUTTED  TO  SELLER,  IS  LIM-
ITED TO THE “LIMITED WARRANTY” OF REPAIR AND/OR REPLACEMENT AS SO 
STATED IN OUR WARRANTY OF PRODUCT.  IN NO EVENT SHALL THE SELLER BE 
LIABLE FOR ANY SPECIAL, INDIRECT, CONSEqUENTIAL OR OTHER DAMAGES OF 
A LIkE GENERAL NATURE, INCLUDING, WITHOUT LIMITATION, LOSS OF PROFITS 
OR  PRODUCTION,  OR  LOSS  OR  EXPENSES  OF  ANY  NATURE  INCURRED  BY  THE 
BUYER OR ANY THIRD PARTY.

UE specifications subject to change without notice.

Содержание TX200

Страница 1: ...ducts do not have any field replaceable parts Any substitution of components may impair suitability for Class I Division 1 TX200 Pressure Transmitter The epoxy resin shall not be subjected to a temperature greater than 125 C Part I Installation Tools Needed Adjustable Wrench Mounting Always locate units where shock vibration and ambient temperature fluctuations are minimal Do not mount in ambient ...

Страница 2: ...l scale pressure range Pcal Cal is the amount of pressure simulated by turning the shunt cal on The Cal is engraved on the TX200A housing and written on the Certificate of Calibration Pcal is the full scale pressure range the user is adjusting to Vzero is the output of the voltage VDC out model with no pressure applied VFSO is the full scale output in volts of a voltage VDC out model Example For a...

Страница 3: ...16 0 54 13 7 B G 1 2 female 1 3 8 1 01 25 7 C 7 16 20 SAE male 15 16 0 77 19 6 D HM4 Autoclave male 15 16 1 10 27 9 E HM6 Autoclave male 15 16 1 29 32 8 F LM4 Autoclave male 15 16 1 18 30 0 G LM6 Autoclave male 15 16 1 32 33 5 H G 1 4 male 15 16 1 03 26 2 J G 1 2 male 1 3 8 1 78 45 2 Wire Color Coding Red VDC Black VDC Green Earth Ground Blue Voltage VDC Output OR M20 METRIC 03 0 to 15 psis 04 0 t...

Страница 4: ...Preventative maintenance and periodic testing is necessary for critical appli cations where damage could endanger property or personnel Electrical ratings stated in literature and on nameplate must not be exceed ed Overload on a switch can cause damage even on the first cycle Wire unit according to local and national electrical codes using wire size recom mended in installation sheet Do not mount ...

Отзывы: