background image

IMT117-07

www.ueonline.com

Dimensions

Dimensional drawings for all models may be found at www.ueonline.com.

B117, E117

Dimension A

Model

Inches

mm

B117 (models 120-121)
Immersion Stem

9.38

238.1

E117 (models 2BSA-8BS)
Bulb & Capillary

8.69

220.6

cp09091000

RECOMMENDED PRACTICES AND WARNINGS 

United Electric Controls Company recommends careful consideration 
of the following factors when specifying and installing UE pressure and temper-
ature units. Before installing a unit, the Installation and Maintenance instruc-
tions provided with unit must be read and understood. 

•  To  avoid  damaging  unit,  proof  pressure  and  maximum  temperature  limits 

stated in literature and on nameplates must never be exceeded, even by surg-
es in the system. Operation of the unit up to maximum pressure or tempera-
ture is acceptable on a limited basis (e.g., start-up, testing) but continuous 
operation  must  be  restricted  to  the  designated  adjustable  range.  Excessive 
cycling at maximum pressure or temperature limits could reduce sensor life.

•  A  back-up  unit  is  necessary  for  applications  where  damage  to  a  primary 

unit could endanger life, limb or property. A high or low limit switch is nec-
essary for applications where a dangerous runaway condition could result.

•  The  adjustable  range  must  be  selected  so  that  incorrect,  inadvertent  or 

malicious setting at any range point cannot result in an unsafe system con-
dition.  

•  Install  unit  where  shock,  vibration  and  ambient  temperature  fluctuations 

will  not  damage  unit  or  affect  operation.  When  applicable,  orient  unit  so 
that  moisture  does  not  enter  the  enclosure  via  the  electrical  connection. 
When  appropriate,  this  entry  point  should  be  sealed  to  prevent  moisture 
entry.

•  Unit must not be altered or modified after shipment. Consult UE if modifi-

cation is necessary.  

•  Monitor  operation  to  observe  warning  signs  of  possible  damage  to  unit, 

such as drift in set point or faulty display.  Check unit immediately.

•  Preventative  maintenance  and  periodic  testing  is  necessary  for  critical 

applications where damage could endanger property or personnel.

•  Electrical  ratings  stated  in  literature  and  on  nameplate  must  not  be 

exceeded. Overload on a switch can cause damage, even on the first cycle.  
Wire unit according to local and national electrical codes, using wire size 
recommended in installation sheet.

•  Do not mount unit in ambient temp. exceeding published limits.

LIMITED WARRANTY

Seller  warrants  that  the  product  hereby  purchased  is,  upon  delivery,  free  from 
defects in material and workmanship and that any such product which is found 
to be defective in such workmanship or material will be repaired or replaced by 
Seller  (Ex-works,  Factory,  Watertown,  Massachusetts.  INCOTERMS);  provided, 
however, that this warranty applies only to equipment found to be so defective 
within a period of 24 months from the date of manufacture by the Seller. Seller 
shall  not  be  obligated  under  this  warranty  for  alleged  defects  which  examina-
tion  discloses  are  due  to  tampering,  misuse,  neglect,  improper  storage,  and  in 
any  case  where  products  are  disassembled  by  anyone  other  than  authorized 
Seller’s  representatives.  EXCEPT  FOR  THE  LIMITED  WARRANTY  OF  REPAIR 
AND  REPLACEMENT  STATED  ABOVE,  SELLER  DISCLAIMS  ALL  WARRANTIES 
WHATSOEVER  WITH  RESPECT  TO  THE  PRODUCT,  INCLUDING  ALL  IMPLIED 
WARRANTIES  OF  MERCHANTABILITY  OR  FITNESS  FOR  ANY  PARTICULAR 
PURPOSE. 

LIMITATION OF SELLER’S LIAbILITY

Seller’s  liability  to  Buyer  for  any  loss  or  claim,  including  liability  incurred  in 
connection  with  (i)  breach  of  any  warranty  whatsoever,  expressed  or  implied, 
(ii)  a  breach  of  contract,  (iii)  a  negligent  act  or  acts  (or  negligent  failure  to 
act) committed by Seller, or (iv) an act for which strict liability will be inputted 
to  seller,  is  limited  to  the  “limited  warranty”  of  repair  and/or  replacement  as 
so stated in our warranty of product.  In no event shall the Seller be liable for 
any  special,  indirect,  consequential  or  other  damages  of  a  like  general  nature, 
including, without limitation, loss of profits or production, or loss or expenses of 
any nature incurred by the buyer or any third party.

UE specifications subject to change without notice.

Temperature Sensors

Immersion Stem 

Models 120-121

Bulb & Capillary 

Models 2BSA - 8BS

180 dexter avenue, p.o. box 9143 

watertown, Ma  02471-9143  usa 

Telephone: 617 926-1000    fax: 617 926-2568

http://www.ueonline.com

U N I T E D   E L E C T R I C 

C O N T R O L S

7-1/8

[181mm]

Ø3/8 [9.5 mm]

B*

3/16

(REF)

Ø5/32 (REF)

* USE DIMENSION “B” 

FOR SEPERABLE WELL 

INSTALLATIONS.

3/4-NPT THRU NEAR WALL ONLY

Ø7/8 KNOCKOUT ON OPPOSITE & 

CENTERED ON REAR OF ENCLOSURE

Dimension B

Model Inches mm

2BSA

2-5/8 66.7

2BSB

2-5/8 66.7

3BS

2-1/8 54.0

4BS

6-3/4 171.5

5BS

5

127.0

8BS

3-1/4 82.6