SPECIFICATIONS

STORAGE TEMPERATURE 

           -65° to 160°F (-54 to 71°C)

AMBIENT

                                      -40° to 160°F (-40 to 71°C); models 520-548, 700-706: 0 to 160°F 

TEMPERATURE LIMITS

                (-18 to 71°C); Set point typically shifts less than 1% of range for a 50°F  

 

                                                       (28°C) ambient temperature change

SET POINT REPEATABILITY 

        Temperature models: ± 1% of adjustable range 

                                                       Pressure models 15623, 171-174, 218, 270-376, 520-535, 540-543, 700-   
                                                       706, 560-564: ± 1% of adjustable range; models  190-194, 183-189, 483-   
                                                         494, 544-548, 565-567, 610-680: ±1.5% of adjustable range 

                                                         Internal set point lock on all pressure models

SHOCK

                                          Set point repeats after 15 G, 10 millisecond duration

VIBRATION

                                    Set point repeats after 2.5 G, 5-500 Hz

ENCLOSURE 

                                 Die cast aluminum, epoxy powder coated, gasketed, captive cover screws

ENCLOSURE CLASSIFICATION 

  Designed to meet NEMA 4X requirements

SWITCH OUTPUT

                          One SPDT snap action switch; switch may be wired  

 

 

 

                                                       “normally open” or “normally closed”

ELECTRICAL RATING

                    15 A 125/250/480 VAC resistive except for H100-15623, 20A 125/250/   

                                                         480 VAC resistive, B100-13546 and E100-13545, 22A/480 VAC

WEIGHT 

                                       2-7 lbs; Varies with model

ELECTRICAL CONNECTION

         1/2” NPT (female); Two 7/8” diameter knockouts 

PRESSURE CONNECTION

            Models 15623, 218, 270-376, 610-680, 701-706: 1/4” NPT (female);  

                                                       Models: 171-194, 483-494, 520-535: 1/2” NPT (female); 
                                                       Models 540-548: 1/8” NPT (female); Models 560-564: 2” Sanitary  

 

                                                       Fitting; Models 565-567: 1.5” Sanitary Fitting (Sanitary fittings mate  

 

                                                       with Tri-Clamp

®

 fitting systems)

TEMPERATURE ASSEMBLY

          Bulb and capillary:  6 feet 304 stainless steel except for E100-13545, 10 feet  

                                                       304 stainless steel

                                                       Immersion stem: nickel-plated brass (standard length only); 

                                                       optional 316L stainless steel

FILL

                                                Models 1BS/BC are solvent filled, models 2-8 non-toxic oil filled

TEMPERATURE DEADBAND

       Type 

F

 typically 1% and type 

B

C

, and 

E

 typically 2% of range under  

 

                                                       laboratory conditions (70°F ambient circulating bath at rate of 1/2°F 
                                                       per minute change)

HEAT TRACING OR

                      Thermostats designed specifically for heat tracing and freeze protection  

FREEZE PROTECTION 

                  ambient sensing applications are available with types B100 and E100

Содержание 100 Serie

Страница 1: ...NG CHECK THE SENSOR MODEL SELECTED FOR COMPATIBILITY TO THE PROCESS MEDIA IN CONTACT WITH THE SENSOR AND WETTED PARTS The H100 and H100K differential pressure switches are activated when a bellows diaphragm or piston sensor responds to a pressure change This response at a pre determined set point actuates a single snap acting switch converting the pressure signal into an electrical signal Control ...

Страница 2: ...by tightening adjustment lock onto it See diagram 1 Controls include uncalibrated reference scales for high low or mid range settings Adjustable Differential Models Model 15623 and control types with option code 1519 incorporate a snap switch with internal adjustment wheel Turning this wheel raises or lowers the pressure rise set point The fall set point remains constant Consult factory for additi...

Страница 3: ...6 7 56 192 0 1 2 188 189 6 62 168 1 1 2 190 194 6 63 168 4 1 2 218 274 6 56 166 6 1 4 358 376 7 03 178 6 1 4 483 486 7 56 192 0 1 2 488 489 6 62 168 1 1 2 490 494 6 63 168 4 1 2 520 525 8 44 214 4 1 2 530 535 8 00 203 2 1 2 540 548 8 34 211 8 1 8 560 564 6 62 168 1 2 Sanitary fitting 565 567 6 62 168 1 1 1 2 Sanitary fitting 610 616 7 00 177 8 1 4 680 6 97 177 0 1 4 701 706 6 57 166 9 1 4 15623 6 ...

Страница 4: ...n the first cycle Wire unit according to local and national electrical codes using wire size recommended in installation sheet Do not mount unit in ambient temp exceeding published limits LIMITED WARRANTY Seller warrants that the product hereby purchased is upon delivery free from defects in material and workmanship and that any such product which is found to be defective in such workmanship or ma...

Страница 5: ...reeze Protection Thermostats Proof Pressures to 10 000 psi 689 5 bar Adjustable Ranges Pressure 30 Hg Vac to 5000 psi 1 to 344 7 bar wc Ranges 300 wc Vacuum to 250 wc Pressure 746 7 to 622 3 mbar Differential Pressure 0 2 wcd to 500 psid 0 5 mbar to 34 5 bar Temperature 180 to 650 F 117 8 to 343 3 C PRESSURE VACUUM DIFFERENTIAL PRESSURE AND TEMPERATURE SWITCHES 1 0 0 B 0 2 100 Series 100 Seri es ...

Страница 6: ...ries are heat tracing freeze protection processing equipment pumps compressors inputs for annunciator panels and fire suppression systems overview features UL listed and cUL certified CE compliant to low voltage directive and pressure equipment directive Single switch SPDT or DPDT output Welded stainless steel diaphragm models Ultra low pressure wc models Optional sensor material for corrosive med...

Страница 7: ...ly closed ELECTRICAL RATING 15 A 125 250 480 VAC resistive except for H100 15623 20A 125 250 480 VAC resistive B100 13546 and E100 13545 22A 480 VAC WEIGHT 2 7 lbs Varies with model ELECTRICAL CONNECTION 1 2 NPT female Two 7 8 diameter knockouts PRESSURE CONNECTION Models 15623 218 270 376 610 680 701 706 1 4 NPT female Models 171 194 483 494 520 535 1 2 NPT female Models 540 548 1 8 NPT female Mo...

Страница 8: ...0 Vac to 10 24 9 to 24 9 0 1 to 0 6 0 2 to 1 5 50 3 4 100 6 9 532 50 Vac to 50 124 5 to 124 5 0 1 to 3 0 2 to 7 5 50 3 4 100 6 9 533 0 5 to 5 0 1 2 to 12 4 0 1 to 0 3 0 2 to 0 7 50 3 4 100 6 9 534 2 5 to 50 6 2 to 124 5 0 1 to 0 8 0 2 to 2 0 50 3 4 100 6 9 535 10 to 250 24 9 to 622 3 0 1 to 10 0 2 to 24 9 50 3 4 100 6 9 psi bar psi bar psi bar psi bar Welded 316L stainless steel diaphragm with 1 2...

Страница 9: ...1 3 50 to 300 3 4 to 20 7 4000 275 8 7000 482 6 Welded 316 stainless steel diaphragm with 1 2 NPT female pressure connection large 0 72 orifice for clean out purposes Lower75 rangespan Top25 rangespan psi bar psi bar psi bar psi bar psi bar 190 5 to 30 0 3 to 2 1 1 to 3 0 07 to 0 2 6 max 0 4 1500 103 4 2500 172 4 191 10 to 100 0 7 to 6 9 1 to 8 0 07 to 0 6 15 max 1 0 1500 103 4 2500 172 4 192 15 t...

Страница 10: ...0 5 2 to 68 9 30 to 150 2 07 to 10 3 6000 413 7 10 000 689 5 612 125 to 3000 8 6 to 206 8 40 to 250 2 76 to 17 2 6000 413 7 10 000 689 5 616 700 to 5000 48 3 to 344 7 40 to 375 2 76 to 25 9 6000 413 7 10 000 689 5 316 stainless steel bellows with 1 4 NPT female pressure connection Not recommended for gas applications or for rapid or high cycling pressure changes 680 100 to 1700 6 9 to 117 2 9 to 4...

Страница 11: ...to 337 8 690 365 6 10 5 3 8 x 31 4 Type F100 Stainless steel bulb and capillary no reference dial 1BS 180 to 120 117 8 to 48 9 170 76 6 N A 3 8 x 33 4 2BS 125 to 350 87 2 to 176 7 400 204 4 N A 3 8 x 25 8 3BS 125 to 500 87 2 to 260 550 287 8 N A 3 8 x 21 8 4BS 40 to 120 40 to 48 9 170 76 6 N A 3 8 x 63 4 5BS 40 to 180 40 to 82 2 230 110 N A 3 8 x 5 6BS 0 to 250 17 8 to 121 1 300 148 8 N A 3 8 x 41...

Страница 12: ... A 125 250 480 VAC resistive adjustment wheel changes rise setting only If adjustment on fall setting is required use primary adjustment NOT AVAILABLE TYPES B100 E100 OR MODELS 171 194 483 494 540 567 610 616 1530 External manual reset 15 A 125 250 480 VAC resistive latches on rise 1535 High ambient 15 A 125 250 VAC resistive temperatures up to 250 F 145 C NOT AVAILABLE MODELS 520 535 1537 Vapor s...

Страница 13: ...WC RANGES AVAILABLE MODELS 520 525 XC001 Aluminum pressure connection Viton diaphragm Viton O ring XC002 Aluminum pressure connection Kapton diaphragm Buna N O ring XC003 Aluminum pressure connection Kapton diaphragm Viton O ring XC004 316L Stainless steel pressure connection 316L stainless steel diaphragm Viton O ring Over range pressure is limited to 100 psi XC005 316L Stainless steel pressure c...

Страница 14: ...pt Model 13546 W139 SD6225 139 3 4 NPT X 1 23 32 BT BRASS W140 SD6225 140 3 4 NPT X 1 23 32 BT 316 ST ST W000 IMMERSION STEM AND THERMOWELLS Note Option W000 is a special Immersion Stem construction that has no external thread This option fits inside a special thermowell and is secured with a set screw Option Description W000 Immersion stem only Brass W097 Immersion stem and thermowell Includes W0...

Страница 15: ...86 7 56 192 0 1 2 188 189 6 62 168 1 1 2 190 194 6 63 168 4 1 2 218 274 6 56 166 6 1 4 358 376 7 03 178 6 1 4 483 486 7 56 192 0 1 2 488 489 6 62 168 1 1 2 490 494 6 63 168 4 1 2 520 525 8 44 214 4 1 2 530 535 8 00 203 2 1 2 560 564 6 62 168 1 2 Sanitary Fitting 565 567 6 62 168 1 11 2 Sanitary Fitting 610 616 7 00 177 8 1 4 680 6 97 177 0 1 4 701 706 15623 6 56 166 9 1 4 Temperature 120 121 13546...

Страница 16: ... storage and in any case where products are disassembled by anyone other than authorized Seller s representatives EXCEPT FOR THE LIMITED WARRANTY OF REPAIR AND REPLACEMENT STATED ABOVE SELLER DISCLAIMS ALL WARRANTIES WHATSOEVER WITH RESPECT TO THE PRODUCT INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE LIMITATION OF SELLER S LIABILITY SELLER S LIABILITY TO...

Отзывы: