UE 100 Serie Скачать руководство пользователя страница 1

IMP100-06

sure connection. Low pressure and differential pressure units, models 

520-535,  540-543,  544-548,  are  also  available  with  an  optional 

surface  mounting  bracket.  Should  the  control  be  installed  where con-

densation is expected, vertical mounting is recommended as a means of 

keeping water away from switch terminals.

Never use the enclosure for leverage to hand tighten the pressure con-

nection.  Always use a wrench to tighten the pressure connection to the 

pipe.To prevent damaging the pressure sensor, use a back-up wrench 

to hold the hex nut in place when surface mounting.  

On models supplied with an external manual reset button, be sure to 

leave sufficient finger space over the reset button for the operator to 

reset the control. See Mounting Diagram.

WIRING

DISCONNECT ALL SUPPLY CIRCUITS BEFORE WIRING.

 

ELECTRICAL  RATINGS  STATED  IN  LITERATURE  AND  ON 

NAMEPLATES  SHOULD NEVER  BE  EXCEEDED.  OVERLOAD 

ON  A  SWITCH  CAN  CAUSE  FAILURE  ON  THE  FIRST  CYCLE. 

WIRE UNITS ACCORDING TO NATIONAL AND LOCAL ELECTRICAL 

CODES. MAXIMUM RECOMMENDED WIRE SIZE IS 14 AWG. 

Remove  the  two  screws  retaining  the  cover  and  cover  gasket.  Two 

cast-in  knockouts  for  1/2”  conduit  are  located  on  the  side  and 

back  of  enclosure.    These  can  easily  be  knocked  out  by  placing  the 

blade  of  a  screwdriver  in  the  groove  and  tapping  sharply  with  a 

hammer.  A  1/2”  NPT  conduit  connection  is  also  provided  on 

the  left  hand  side  of   the  enclosure.  The  three  switch  terminals 

are  clearly  labeled  “common”,  “normally  open”  and  “normally 

closed”.    For  switches  supplied  with  leadwires,  the  following  color 

coding applies:

Manual

DPDT

Reset

(Option 1010)

SPDT

SWT1

SWT2

 Common

Violet

Violet

Yellow

Normally Open

Blue

Blue

Orange

Normally Closed Black

Black

Red

GENERAL

BEFORE  INSTALLING,  CHECK  THE  SENSOR  MODEL  SELECTED 
FOR COMPATIBILITY TO THE PROCESS MEDIA IN CONTACT WITH 
THE SENSOR AND WETTED PARTS.

The H100 and H100K differential pressure switches are activated when 

a bellows, diaphragm or piston sensor responds to a pressure change. 

This response, at a pre-determined set point, actuates a single snap-

acting  switch,  converting  the  pressure  signal  into  an  electrical  signal. 

Control set point may be varied by turning the internal adjustment hex. 

(See Adjustment -PART II).

PROOF PRESSURE* LIMITS STATED IN THE LITERATURE AND ON 

NAMEPLATES  MUST  NEVER  BE  EXCEEDED,  EVEN  BY  SURGES 

IN  THE  SYSTEM.    OCCASIONAL  OPERATION  OF  UNIT  UP  TO 

PROOF  PRESSURE IS ACCEPTABLE (E.G., START-UP, TESTING).  

CONTINUOUS OPERATION SHOULD NOT EXCEED THE DESIGNATED OVER 

RANGE PRESSURE.

*Proof Pressure
The maximum pressure to which a pressure sensor may be occasionally 

subjected, which causes no permanent damage (e.g., start-up, testing).  

The unit may require re-gapping.

 

Tools Needed

Adjustable Wrench

Screwdriver

Hammer (for alternate wire knockouts)

MOUNTING

INSTALL UNIT WHERE SHOCK, VIBRATION AND TEMPERATURE 

FLUCTUATIONS  ARE  MINIMAL.    ORIENT  UNIT  SO  THAT  MOIS-

TURE  IS  PREVENTED  FROM  ENTERING  THE  ENCLOSURE.    IF 

UNIT IS  BEING INSTALLED WHERE HEAVY CONDENSATION IS EXPECTED, 

VERTICAL MOUNTING (PRESSURE CONNECTION DOWN) IS REQUIRED. DO 

NOT MOUNT IN AMBIENT TEMPERATURES EXCEEDING PUBLISHED LIMITS.

Controls  may  be  mounted  and  operated  in  any 

position.  They may be surface mounted via the two mounting ears on 

either side of the enclosure, or directly to a rigid pipe by using the pres-

100 Series

Pressure Switch

Types H100, H100K 

(Differential Pressure)

IMP100-06

Please read all instructional literature carefully and thoroughly before starting.  Refer to the final page for the listing of Recommended 
Practices, Liabilities and Warranties.

Part I - Installation

U N I T E D   E L E C T R I C  
C O N T R O L S

Installation and Maintenance 

Instructions

Содержание 100 Serie

Страница 1: ...NG CHECK THE SENSOR MODEL SELECTED FOR COMPATIBILITY TO THE PROCESS MEDIA IN CONTACT WITH THE SENSOR AND WETTED PARTS The H100 and H100K differential pressure switches are activated when a bellows diaphragm or piston sensor responds to a pressure change This response at a pre determined set point actuates a single snap acting switch converting the pressure signal into an electrical signal Control ...

Страница 2: ...by tightening adjustment lock onto it See diagram 1 Controls include uncalibrated reference scales for high low or mid range settings Adjustable Differential Models Model 15623 and control types with option code 1519 incorporate a snap switch with internal adjustment wheel Turning this wheel raises or lowers the pressure rise set point The fall set point remains constant Consult factory for additi...

Страница 3: ...6 7 56 192 0 1 2 188 189 6 62 168 1 1 2 190 194 6 63 168 4 1 2 218 274 6 56 166 6 1 4 358 376 7 03 178 6 1 4 483 486 7 56 192 0 1 2 488 489 6 62 168 1 1 2 490 494 6 63 168 4 1 2 520 525 8 44 214 4 1 2 530 535 8 00 203 2 1 2 540 548 8 34 211 8 1 8 560 564 6 62 168 1 2 Sanitary fitting 565 567 6 62 168 1 1 1 2 Sanitary fitting 610 616 7 00 177 8 1 4 680 6 97 177 0 1 4 701 706 6 57 166 9 1 4 15623 6 ...

Страница 4: ...n the first cycle Wire unit according to local and national electrical codes using wire size recommended in installation sheet Do not mount unit in ambient temp exceeding published limits LIMITED WARRANTY Seller warrants that the product hereby purchased is upon delivery free from defects in material and workmanship and that any such product which is found to be defective in such workmanship or ma...

Страница 5: ...reeze Protection Thermostats Proof Pressures to 10 000 psi 689 5 bar Adjustable Ranges Pressure 30 Hg Vac to 5000 psi 1 to 344 7 bar wc Ranges 300 wc Vacuum to 250 wc Pressure 746 7 to 622 3 mbar Differential Pressure 0 2 wcd to 500 psid 0 5 mbar to 34 5 bar Temperature 180 to 650 F 117 8 to 343 3 C PRESSURE VACUUM DIFFERENTIAL PRESSURE AND TEMPERATURE SWITCHES 1 0 0 B 0 2 100 Series 100 Seri es ...

Страница 6: ...ries are heat tracing freeze protection processing equipment pumps compressors inputs for annunciator panels and fire suppression systems overview features UL listed and cUL certified CE compliant to low voltage directive and pressure equipment directive Single switch SPDT or DPDT output Welded stainless steel diaphragm models Ultra low pressure wc models Optional sensor material for corrosive med...

Страница 7: ...ly closed ELECTRICAL RATING 15 A 125 250 480 VAC resistive except for H100 15623 20A 125 250 480 VAC resistive B100 13546 and E100 13545 22A 480 VAC WEIGHT 2 7 lbs Varies with model ELECTRICAL CONNECTION 1 2 NPT female Two 7 8 diameter knockouts PRESSURE CONNECTION Models 15623 218 270 376 610 680 701 706 1 4 NPT female Models 171 194 483 494 520 535 1 2 NPT female Models 540 548 1 8 NPT female Mo...

Страница 8: ...0 Vac to 10 24 9 to 24 9 0 1 to 0 6 0 2 to 1 5 50 3 4 100 6 9 532 50 Vac to 50 124 5 to 124 5 0 1 to 3 0 2 to 7 5 50 3 4 100 6 9 533 0 5 to 5 0 1 2 to 12 4 0 1 to 0 3 0 2 to 0 7 50 3 4 100 6 9 534 2 5 to 50 6 2 to 124 5 0 1 to 0 8 0 2 to 2 0 50 3 4 100 6 9 535 10 to 250 24 9 to 622 3 0 1 to 10 0 2 to 24 9 50 3 4 100 6 9 psi bar psi bar psi bar psi bar Welded 316L stainless steel diaphragm with 1 2...

Страница 9: ...1 3 50 to 300 3 4 to 20 7 4000 275 8 7000 482 6 Welded 316 stainless steel diaphragm with 1 2 NPT female pressure connection large 0 72 orifice for clean out purposes Lower75 rangespan Top25 rangespan psi bar psi bar psi bar psi bar psi bar 190 5 to 30 0 3 to 2 1 1 to 3 0 07 to 0 2 6 max 0 4 1500 103 4 2500 172 4 191 10 to 100 0 7 to 6 9 1 to 8 0 07 to 0 6 15 max 1 0 1500 103 4 2500 172 4 192 15 t...

Страница 10: ...0 5 2 to 68 9 30 to 150 2 07 to 10 3 6000 413 7 10 000 689 5 612 125 to 3000 8 6 to 206 8 40 to 250 2 76 to 17 2 6000 413 7 10 000 689 5 616 700 to 5000 48 3 to 344 7 40 to 375 2 76 to 25 9 6000 413 7 10 000 689 5 316 stainless steel bellows with 1 4 NPT female pressure connection Not recommended for gas applications or for rapid or high cycling pressure changes 680 100 to 1700 6 9 to 117 2 9 to 4...

Страница 11: ...to 337 8 690 365 6 10 5 3 8 x 31 4 Type F100 Stainless steel bulb and capillary no reference dial 1BS 180 to 120 117 8 to 48 9 170 76 6 N A 3 8 x 33 4 2BS 125 to 350 87 2 to 176 7 400 204 4 N A 3 8 x 25 8 3BS 125 to 500 87 2 to 260 550 287 8 N A 3 8 x 21 8 4BS 40 to 120 40 to 48 9 170 76 6 N A 3 8 x 63 4 5BS 40 to 180 40 to 82 2 230 110 N A 3 8 x 5 6BS 0 to 250 17 8 to 121 1 300 148 8 N A 3 8 x 41...

Страница 12: ... A 125 250 480 VAC resistive adjustment wheel changes rise setting only If adjustment on fall setting is required use primary adjustment NOT AVAILABLE TYPES B100 E100 OR MODELS 171 194 483 494 540 567 610 616 1530 External manual reset 15 A 125 250 480 VAC resistive latches on rise 1535 High ambient 15 A 125 250 VAC resistive temperatures up to 250 F 145 C NOT AVAILABLE MODELS 520 535 1537 Vapor s...

Страница 13: ...WC RANGES AVAILABLE MODELS 520 525 XC001 Aluminum pressure connection Viton diaphragm Viton O ring XC002 Aluminum pressure connection Kapton diaphragm Buna N O ring XC003 Aluminum pressure connection Kapton diaphragm Viton O ring XC004 316L Stainless steel pressure connection 316L stainless steel diaphragm Viton O ring Over range pressure is limited to 100 psi XC005 316L Stainless steel pressure c...

Страница 14: ...pt Model 13546 W139 SD6225 139 3 4 NPT X 1 23 32 BT BRASS W140 SD6225 140 3 4 NPT X 1 23 32 BT 316 ST ST W000 IMMERSION STEM AND THERMOWELLS Note Option W000 is a special Immersion Stem construction that has no external thread This option fits inside a special thermowell and is secured with a set screw Option Description W000 Immersion stem only Brass W097 Immersion stem and thermowell Includes W0...

Страница 15: ...86 7 56 192 0 1 2 188 189 6 62 168 1 1 2 190 194 6 63 168 4 1 2 218 274 6 56 166 6 1 4 358 376 7 03 178 6 1 4 483 486 7 56 192 0 1 2 488 489 6 62 168 1 1 2 490 494 6 63 168 4 1 2 520 525 8 44 214 4 1 2 530 535 8 00 203 2 1 2 560 564 6 62 168 1 2 Sanitary Fitting 565 567 6 62 168 1 11 2 Sanitary Fitting 610 616 7 00 177 8 1 4 680 6 97 177 0 1 4 701 706 15623 6 56 166 9 1 4 Temperature 120 121 13546...

Страница 16: ... storage and in any case where products are disassembled by anyone other than authorized Seller s representatives EXCEPT FOR THE LIMITED WARRANTY OF REPAIR AND REPLACEMENT STATED ABOVE SELLER DISCLAIMS ALL WARRANTIES WHATSOEVER WITH RESPECT TO THE PRODUCT INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE LIMITATION OF SELLER S LIABILITY SELLER S LIABILITY TO...

Отзывы: