Adjust Sensitivity to near Mid Scale. If full scale,
impossible to tell where starting point is.
201
OPERATION
While operating the 'Grease Caddy,' Headphones
should be worn at all times to hear the Change
of sound in the bearing.
IT’S IMPORTANT TO
LISTEN AND
OBSERVE
THE DISPLAY WHILE
LUBING!!!
Full Scale
Sensitivity Too High
Mid Scale
Adjusted Sensitivity
LEDs of 201 Ultraprobe are present to show
change in sound level.
THE
LEDS
ARE ONLY THERE TO
SHOW A CHANGE IN SOUND
LEVEL.
Add lube until sound level lowers, levels out, and
will not decrease more. If Sound Level Increases,
Immediately STOP Adding Lube!
Lube Slowly And Add Lube A LITTLE AT A TIME.
Give Time For Response Of Change
.
**If sound level never decreases, NEVER exceed
manufacture’s calculated grease capacity for the bearing.
DO NOT OVERLUBE.