The
UDEVAC
system is a compact solution for voice alarm systems.
The system's features and functionalities have been designed based on the
EN54-16 standard.
The paging desk
PZ-112
is part of the
UDEVAC
system, it enables the
monitoring and remote operation of the main functionalities of the main station
SLA-112
(alarms, emergency status, broadcasting messages; among others).
Internally, the device includes supervision for the microphone, power supply
and communication, following the safety standards assigned for this type of
applications.
The paging desk
PZ-112
, by using a GUI integrated within its 7'' color
touchscreen, it enables the user to browse, manage and select zones or group
zones to which messages can be broadcasted to by using the included
gooseneck microphone.
Thanks to the FTP connection and UDE's AudioLink Protocol, it is possible to
broadcast 2 different messages simultaneously from 2 different locations with
up to 1000m distance from the main station. Besides, if the distance between
the paging desk and the
SLA-112
main station is lower than 50m, by using the
Direct Power technology the paging desk can be powered supplied through the
FTP cable without the need of adding any external power supply source.
Within a single installation, the system can handle up to 30 paging desks with a
configurable priority between them.
-Complies with EN54-16.
-Supervision for paging microphone.
Gooseneck's length: 300mm.
-Emergency mode and evacuation
messages activation.
-24VDC supply supervision.
-Supervision for FTP connection with SLA-112.
-Connection to up to 30 paging desks.
-Standard Paging Broadcasting per zones.
-Broadcasting of pre-recorded messages.
-Configurable priority between paging desks.
-7'' color touch screen for configuration and
operation of the system.
-Tone controls.
-XLR back connector for fireman microphone.
-Configurable Chime Push-button.
PAGING DESK WITH SUPERVISION
UDEVAC
System
Engineered and made in E.U.
PZ-112
FEATURES
16
POWER +24VDC
IN
OUT
AUDIO LINK
EXT
MIC
CH1
IN
OK
CH2
OUT
FAIL
FAIL
AUDIO
DATA
LINK
DEVICE
POWER +24VDC
IN
OUT
AUDIO LINK
EXT
MIC
CH1
IN
OK
CH2
OUT
FAIL
FAIL
AUDIO
DATA
LINK
DEVICE
DESCRIPTION
73
314
185
Dimensions in mm.
PZ-112
3
1
610.507A
rev.
1
EQUIPOS Y SISTEMAS MEGAFONÍA / INTERCOM
PUBLIC ADDRESS SYSTEMS
BARCELONA - SPAIN
Tel.: +34 934 772 854 / +34 609 914 787
EMG
SPEECH
USB
FAULT
ON