Configure the identifiers of each PZ-1000A desk (from 1 to 16).

Each PZ-1000A must have a different identifier on the bus.

Power switch in OFF

Hold the selector NOTICE GENERAL (ALL AREAS) is activated during the switch to start position.

The display shows "

". Release the button GENERAL NOTICE.

Operate SWITCHES STEERING (up / down) until the display shows the required ID number (example 2).

Validate the identifier by pressing GENERAL NOTICE.

Turn the switch off, and 5 seconds later, put another time in ON.

Whenever you set up the desk, the display shows quickly the identification number (in this case 0.2) and then putting the last
address previously selected.

And configure each console system with its corresponding identifier.

Process:

Ad

CONFIGURE THE IDENTIFIERS OF EACH PZ-1000A DESK

Example 3: Notice to zones 5, 15 and 20:
1.
2.
3.
4.

5.

6.

By SWITCHES STEERING select the number 1 (WZ-1000A no. 1 module) which belong to zone 5.
Activate by the ZONE SELECT button the zone 5. The corresponding LED driver is activated fixed.
By SWITCHES STEERING select the number 2 (WZ-1000A no. 2 module) that belong to areas 15 and 20.
By the ZONE SELECT button activate areas 5 and 10. The corresponding LED drivers are activated fixed. In areas 5, 15 and 20

the music is off (if it was enabled). In all other areas not selected, the music continues

CHIME OF NOTICE: Press the corresponding button (CHIME ON). The associated LED lights while the chime sounds in the

selected area.

NOTICE: By the button (MIC ON / OFF), turn the microphone. The pilot lights. Give the notice. At the end, turn the microphone

back on el pressing button (MIC ON / OFF). Defuse the SELECTOR AREA Number 5, 15 and 20 and in reverse order of
selection.

USE PZ-1000A DESK

TO GIVE NOTICE
Example 1:  We want to give a notice to number 5.
1.
2.

3.

4.

By SWITCHES STEERING select the number 1 (WZ-1000A no. 1 module) which belong to zone 5.
By the ZONE SELECT button activate the zone 5. The corresponding LED driver is activated fixed. In zone 5 the music is off (if it
was enabled). In all other areas not selected, the music continues.
CHIME OF NOTICE: Press the corresponding button (CHIME ON). The associated LED lights the chime sounds in the selected
area.
NOTICE: By the button (MIC ON / OFF), turn on the microphone. The pilot lights. Give the notice. At the end, turn off the
microphone by pressing button (MIC ON / OFF). Defuse the ZONE SELECTOR number 5. The pilot zone 5 LED turns off.

Example 2: Notice to zones 1 to 10

Proceed as in the previous section, but by selecting the 10 ACTIVATION AREAS (TEN AREAS). The 10 areas are activated
simultaneously.

GENERAL NOTICE:

By selecting the GENERAL NOTICE (ALL AREAS) all areas of the system are activated at a time. At the end of the notice,
deselect the GENERAL NOTICE.

Note: Selecting and Deselecting NOTICE, erase all current selections possible.

PZ-1000A /   WZ-1000A

9

5

610.490A

rev.

2

Содержание PZ-1000

Страница 1: ...ion independently or bus operated by the desk PZ 1000A It allows the areas of music and announcements selection It integrates mixer with microphone inputs line and chime notice The system allows a maximum of 30 WZ 1000A modules up to a maximum of 300 zones By two power amplifiers can stream music and announcements selective Maximum distance to desk center 1000 m Memory selection of areas of non vo...

Страница 2: ...NG WZ 1000A 10 ZONES ACTIVATION GENERAL NOTICE ACTIVATION SELECTED AREA LED Button LED button LED button LED button LED button CARILLON ACTIVATION WZ 1000A indicator selected TALK Microphone ON OFF ANNOUNCEMENTS WITH SELECTION AREAS DESK PZ 1000 Output Model Dimensions Weight Bandwidth MICRO Bandwidth LINE Crosstalk input MICRO Croostalk input LINE Power source Consumption Unbalanced 245x144x50 mm...

Страница 3: ...Hz to 18 Khz 80 dB 90 dB 230 VAC 40 W 2 microphone inputs not balanced 2 line inputs not balanced SPECIFICATIONS WZ 1000 200 mV 10K 1 8 mV 600 Properties work by modulating Vox The microphone input has priority over a microphone 2 line 2 and remote PZ 1000A desk The input Line 1 has priority over a microphone microphone 2 line 2 and remote PZ 1000A desk A Connection mode output line 100V B Connect...

Страница 4: ...ANGE ORANGE WHITE 1 2 3 4 5 6 7 8 BLUE BLUE WHITE BROWN BROWN WHITE GREEN GREEN WHITE ORANGE ORANGE WHITE ADDRESS 1 2 3 4 5 6 ON OFF Figura 2 1 a 10 11 a 20 21 a 30 31 a 40 41 a 50 51 a 60 61 a 70 71 a 80 81 a 90 100 a 110 111 a 120 121 a 130 131 a 140 141 a 150 151 a 160 161 a 170 171 a 180 181 a 190 191 a 200 200 a 210 211 a 220 221 a 230 231 a 240 241 a 250 251 a 260 261 a 270 271 a 280 281 a 2...

Страница 5: ...es CHIME OF NOTICE Press the corresponding button CHIME ON The associated LED lights while the chime sounds in the selected area NOTICE By the button MIC ON OFF turn the microphone The pilot lights Give the notice At the end turn the microphone back on el pressing button MIC ON OFF Defuse the SELECTOR AREA Number 5 15 and 20 and in reverse order of selection USE PZ 1000A DESK TO GIVE NOTICE Exampl...

Страница 6: ...is possible to control the PZ 1000A desk The selections and actions in the WZ 1000A desk take precedence over affected from the desk PZ 1000A The DIP switch number 6 must be in OFF position in order to enable the special alarm features When the A or B input is triggered with a close contact all the WZ 1000A zones would be connected to the alarm amplifier In the front panel will flash on in red or ...

Страница 7: ...CH 2 MUSIC IN ALARM IN OUTPUT CH 3 CH 3 MUSIC IN ALARM IN OUTPUT CH 4 CH 4 MUSIC IN ALARM IN OUTPUT CH 5 CH 5 MUSIC IN ALARM IN OUTPUT CH 6 CH 6 MUSIC IN ALARM IN OUTPUT CH 7 CH 7 MUSIC IN ALARM IN OUTPUT CH 8 CH 8 MUSIC IN ALARM IN OUTPUT CH 9 CH 9 MUSIC IN ALARM IN OUTPUT CH 10 CH 10 WZ 1000A COM COM DC 24V OUTPUT LINE IN MIC VOL CHIME VOL PZ 1000A TYPICAL CONNECTION L100V Output AUX LINE 100V 2...

Страница 8: ...CUT THE RESISTANCE AS IF SHOWN IMPORTANT A WZ 1000A used with L100V should not be reused with 0 dB signal M dB WZ 1000A odification to operate with 0 audio signals R1 R2 R1 R3 R4 R5 R6 R7 R8 R9 R10 4 7 PZ 1000A WZ 1000A 9 8 610 490A rev 2 ...

Страница 9: ...E MUSIC IN ALARM IN OUTPUT CH 1 CH 1 MUSIC IN ALARM IN OUTPUT CH 2 CH 2 MUSIC IN ALARM IN OUTPUT CH 3 CH 3 MUSIC IN ALARM IN OUTPUT CH 4 CH 4 MUSIC IN ALARM IN OUTPUT CH 5 CH 5 MUSIC IN ALARM IN OUTPUT CH 6 CH 6 MUSIC IN ALARM IN OUTPUT CH 7 CH 7 MUSIC IN ALARM IN OUTPUT CH 8 CH 8 MUSIC IN ALARM IN OUTPUT CH 9 CH 9 MUSIC IN ALARM IN OUTPUT CH 10 CH 10 WZ 1000A COM COM DC 24V OUTPUT LINE IN MIC VOL...

Отзывы: