5.2. Southern Hemispheres (SOU).
For Southern Hemisphere installations, ignore these(N, S,)
and face
the solar panel to the North
(and in a sunny
position,This ensures the solar cell receives as much sun as
possible and orients wind direction.) when installing the
Integrated outdoor transmitter.
Step 1:
Install the Integrated outdoor transmitter and face the
solar panel North.
Step 2:
Console operation is set to Southern Hemispheres
(
SOU
in the time area) in Location division.
Note:
Console has to be location division setting so that
the directions on the sensor are matching with your real
location. Permanent wind direction error
(
read approximately
180º
)
will be introduced when the wind direction sensor is not
positioned correctly during installation.
First attach a pipe to a permanent structure and then attach
the sensor package to it . The U-Bolts will accommodate a
pipe diameter of 30-45mm (pipe not included), as shown in
Figure 14.