background image

BLE RS-232 adapter user manual V1.0 

 

2018.05.22 

 

3

Pin 

Signal 

DTE Direction 

DCE Direction 

Description 

N/A 

 

 

 

RxD 

Output 

Input 

Transmitted data 

TxD 

Input 

Output 

Received data 

N/A 

 

 

 

GND 

 

 

Ground 

N/A 

 

 

 

RTS 

Input 

Output 

Clear to send 

CTS 

Output 

Input 

Request to send (Default) 

VCC 

 

 

Power Input (5~27 VDC) 

 

3. Power supply: 

3.1 Voltage: 5~27 VDC, 

Don’t exceed the limit.

 

3.2 There’re 3 ways to power the adapter: Mini USB, 2P Terminal Block (Blue) and pin9 

of DB9, please choose one.  

Don’t power the adapter by more than one source.

 

3.3 The mini USB to type A cable is inside the standard package. 

 

4. Specifications: 

4.1 Default value: 

 

Baud rate: 9,600 bps 

 

Data bit: 8 

 

Parity: none 

 

Stop bit: 1 

 

Flow control: none 

 

Device Name: BLE 232 

 

Pin code:“123456” if necessary 

4.2 Serial Port: 

 

Baud Rate: 1.2/2.4/4.8/9.6/19.2/38.4/57.6/115.2/230.4/460.8/921.6 Kbps 

 

Parity: none/even/odd 

 

Stop bit: 1/1.5/2 

 

Data bit: 7/8 

Remark: The GATT service and AT command will support all the functions, please 

check the page 4 section 5 and page 5 section 6. 

4.3 Range: max. 50 m in open space (The range is depend on the real environment) 

4.4 TX Power: Max. 3 dBm 

4.5 RX Sensitivity: -89 dBm typical 

4.6 TX current consumption of 15.6 mA (radio only, 0 dbm) 

4.7 Operation Temperature: –40 °C to +70 °C 

4.8 Dimensions: 87 mm (L) x 34 mm (W) x 18 mm (H) 

4.9 Antenna Gain: max. 2 dB 

Remark: All contents are subject to change without notice. 

Содержание BLE-232D

Страница 1: ...nts BLE RS 232 adapter x 1 A4 User manual x 1 Mini USB Cable x 1 2 Profile 2 1 Top view LED Status Description Data LED flash Data transmission Data LED solid on No data transmission Link LED solid on...

Страница 2: ...2 00 None 01 Odd 10 Odd 11 Even 0 Slave 1 Master 110 2400 111 4800 000 9600 001 19200 010 38400 011 57600 100 115200 101 230400 Remark 1 000000000 by default in red bold character 2 The GATT service a...

Страница 3: ...kage 4 Specifications 4 1 Default value Baud rate 9 600 bps Data bit 8 Parity none Stop bit 1 Flow control none Device Name BLE 232 Pin code 123456 if necessary 4 2 Serial Port Baud Rate 1 2 2 4 4 8 9...

Страница 4: ...eName 15 bytes 00031234 0000 1000 8000 00805F9B0134 UUID_Reboot 1 bytes 00031234 0000 1000 8000 00805F9B0135 UUID_PinID_Setting 6 bytes 00031234 0000 1000 8000 00805F9B0136 UUID_BLE_CONF 7 bytes 00031...

Страница 5: ...eck the connection status between control terminal and the RS 232 adapter Response OK when the connection is ok Response ERROR when the connection is not ok AT Test the RS 232 status when first connec...

Страница 6: ...re the current setting NAME This command is used to specify a device name for the adaptor You can specify a friendly name using 0 to 9 A to Z a to z space and which are all valid characters Note that...

Страница 7: ...delay Default 1 One stop bit 2 Two stop bits Inquire the current setting VERSION This command is used to inquiry the firmware version Inquire the version codes 7 Central and Peripheral Similar like th...

Страница 8: ...ired peripheral on next time when power on Please reset to the default and follow the above procedures if you want to link with other BLE devices 8 APP The APP is used for the configuration and the da...

Отзывы: