6. TROUBLE-SHOOTING   

6.1When the unit get in trouble, check the following point first. 

Troubled function 

Possible reason 

Countermeasure 

No water supply. 

The valve of water line is 
closed. 

Open the valve. 

No operation. 

No electric power. 

Check with tester. 

Off the power switch of 
transformer box. 

Switch on. 

Turn on the UV malfunction 
indicator lamp. 

Replace the UV lamp 

Burn out the fuse. 

Replace to spare fuse. 

Wrong setting of humidistat 
or higher humidity than 
setting level. 

Reset the humidity level of 
the humidistat (set higher 
level for test and then set to 
proper level.) 

Less out put the mist.   

There are water in the duct 
hose. 

Apply to declivity for the 
duct hose. 

6.2 

Other possible reasons for out of order: 

1.

 

The  running  of  the  unit  after  declined  output  of  the  mist  for long hours,  it  may 
cause the damage of the transistor of the PCB. 

2.

 

If the unit is lay down or upside down and switch on the power, float switch will 
operate  to  make  running  of  the  unit  without  water  and  it  cause  damage  the 
transistor of the PCB. 

3.

 

If  the  water  supply  pace  is  slower  than  consumption  pace  of  the  water  to  make 
mist, the water inlet solenoid valve will react ON-Off very often and it may cause 
damage the valve. Minimum water pressure is o.3kgf/cm2. 

4.

 

Big electric surge occurred by lightning strike may cause damage of PCB. 

5.

 

If use megger tester to check PCB, it may cause damage of the PCB. 

6.

 

If the water of the tank has grits, pebbles or iron powder etc, and operate for long 
hours, it may cause the damage of the oscillator. 

7.

 

If the some dirt or dust are caught at the valve, it may cause overflow. 

8.

 

Higher voltage of the electric power supplied than specified voltage. 

 

6.3 Countermeasures 

<In case of declining of mist output at short after 
the installation.> 

1) If the water reservoir is contaminated with some 

oil or adhesive materials used in plumbing, the 
mist  production  will  be  declined.  If  it  might  be 
so,  switch  off  the  power  and  drain  the  water. 
And disassemble the mist outlet part and clean 
the tank with neutral detergent and soft sponge. 
And keep supply the water and drain it until the 
bubble  of  the  detergent  will  disappear  to  make 
clean the tank. 

2) Check the voltage of the electric power supply. If 

it  lowered,  must  be  correct  by  power  service 
station.   

 
 
<In case of declining of mist output after long hours running.> 
1)

 

Check the surface of the oscillator. If it covered by some soil, clean up the surface 
with soft cloth. 

2)

 

If  the  surface  is  damaged  or  the  plating  is  pealed  off,  replace  it  with  a  new 
oscillator because the life has expired. 

water

water

covered with oily film

water surface is 

be generated when the

No or little mist can 

B.Abnormal

a water pillar

Mist generates around

A.Normal

●●

●●

●●

● ●

● ●

●●

●●

● ●

● ●

● ●

●●

●●

●●

●●

●●

●●

●●

●●

● ●

●●

●●

●●

● ●

● ●

●●

●●

●●

●●

● ●

●●

●●

●●

●●

●●

●●

●●

●●

●●

●●

● ●

●●

●●

●●

● ●

●●

●●

●●

●●

●●

●●

●●

●●

●●

● ●

● ●

Содержание FT-F Series

Страница 1: ...idifier unit Please read these instructions thoroughly for correct installation Maintenance and inspection of the unit Keep Handy For Quick Reference UCAN Co Ltd 5 6 19 Sanda cho Hachioji city Tokyo 1...

Страница 2: ...ower Do not touch any electric circuit during power on especially by wet hands It will get electric shock All of electric cable wire should not damage processing pulling or forcibly bending It will ca...

Страница 3: ...s lower then freezing point all of water pipe lines should be protected from freezing Otherwise pipes may brake due to the freezing The life of the oscillator is about 5 000 hours The life sometimes b...

Страница 4: ...u use extension cable for the box be sure to use proper cable 3 The location of the box should be considered about maintenance such as easy removable of the front cover 1 3 Installation of Humidistat...

Страница 5: ...drain pan should not be twisted and set it in slant for water flow Drain pan Hunging type Hunging bolt by customer Humidifier unit Wall mounting bracket Drain pan Humidifier unit Wall mounting type 10...

Страница 6: ...ow out to drainage pipe or drain pan The hose should be set on the slant 6 Leave the black cap intact on the drainage outlet The cap to be removed only for draining water reservoir to do cleaning or m...

Страница 7: ...t waterless operation will make stop the operation of the unit However the water supply solenoid valve has still been opened until shut off the power switch of the unit If switch off the unit the sole...

Страница 8: ...spray nozzle with both hands then lift up the right side of the top cover 3 Pull out the top cover toward the upper right side Condensation formed on the nozzles Please take care not to spill it CAUTI...

Страница 9: ...val method of the fan box Replacement of the oscillators the float sensors or maintenance of the water supply solenoid valve Procedure 1 Unlock the snap lock on both side of the fan box 2 Slide the fa...

Страница 10: ...cation 4 Pull out the bottom cover toward the front side F125 F245 loosen the fixing screws on the bottom side of the bottom cover about twice in advance After that it becomes possible to replace the...

Страница 11: ...is not necessary to remove the nuts 2 Slide the PCB with bracket as shown above Remove the connectors if necessary Replacement method of UV lamp 1 Loosen the M4 screws that fixing the both ends of th...

Страница 12: ...bout twice in advance 3 Pull out the UV lamp Please be careful packing is not twisted or out when replace the UV lamp View from the bottom side UV lamp View from back side FT F125 F245 The back cover...

Страница 13: ...filter 2 Remove the air filter as shown below The method of the cleaning of the air filter Clean up any built up of the dust by hand or blow off by compressed air In case of heavy contamination wash t...

Страница 14: ...up the stem and the float carefully 2 Remove the stopper and pull out the float for the above 3 When taking out the float be sure to see which end is up It must be reassembled in the right direction T...

Страница 15: ...ner must be set between the water line and the water inlet pipe to protect the unit by eliminating the dirt or the dust 1 Close the water supply valve 2 Turn the knob of the strainer holder counter cl...

Страница 16: ...source switch before checking 1 Remove the transformer cover 2 Check the fuse If it burn out replace the spare one fastened to the switch base with the tape 3 Turn on the switch of the main electric...

Страница 17: ...ectric surge occurred by lightning strike may cause damage of PCB 5 If use megger tester to check PCB it may cause damage of the PCB 6 If the water of the tank has grits pebbles or iron powder etc and...

Страница 18: ...the indication is showing under 10 ohm the transistor is OK but if it shows close to ZERO the transistor is out of order Then next step checking should be done Touch red probe PLUS at B side Base and...

Страница 19: ...the duct hose Overflow Deterioration with age No slope provided Dirt caught in the solenoid valve Replace Give the hose some incline Dismantle the valve and clean 2 No spray output at all Trouble fun...

Страница 20: ...UCAN s installation and operation manuals 3 If the products have been modified or altered without written agreement with UCAN 4 Under circumstances of any direct indirect incidental consequential dama...

Отзывы: