Ublox VERA-P173 Скачать руководство пользователя страница 1

 

VERA-P1 series 

Host-based V2X transceiver module 

Data Sheet 
 
 
 
 
 
 
 
 

 

 

Abstract

 

This  technical  data  sheet  describes  the  VERA-P1  series  transceiver  module  that  enables 
development of electronics for Vehicle-to-Everything (V2X) communication systems. The VERA-P1 
series  includes  an  integrated  MAC/LLC/Baseband  processor  and  the  required  RF  front-end 
components. It is connected to a host processor through a USB or SPI interface.  

www.u-blox.com

 

UBX-17004377 

R06_draft 

Содержание VERA-P173

Страница 1: ...transceiver module that enables development of electronics for Vehicle to Everything V2X communication systems The VERA P1 series includes an integrated MAC LLC Baseband processor and the required RF front end components It is connected to a host processor through a USB or SPI interface www u blox com UBX 17004377 R06_draft ...

Страница 2: ... End of Life Production Information Document contains the final product specification This document applies to the following products Product name Type number Firmware version PCN reference Product status VERA P173 VERA P173 00A 00 N A N A Engineering Samples VERA P174 VERA P174 00A 00 N A N A Engineering Samples u blox or third parties may hold intellectual property rights in the products names l...

Страница 3: ...s 15 4 4 Peak current consumption 15 4 5 Radio specifications 16 5 Mechanical specifications 18 5 1 Physical dimensions 18 6 Qualification and approvals 20 6 1 Approvals 20 6 1 1 European Union regulatory compliance 20 6 1 2 FCC compliance 20 6 1 3 FCC IDs 20 6 1 4 Certification in other countries 20 7 Product handling soldering 22 7 1 Packaging 22 7 1 1 Reels 22 7 1 2 Tapes 22 7 2 Shipment storag...

Страница 4: ...VERA P1 series Data Sheet UBX 17004377 R06_draft Page 4 of 30 Confidential A Glossary 28 Related documents 29 Revision history 29 Contact 30 ...

Страница 5: ...ehicle units OBU On Board Unit and infrastructure RSU Road Side Unit They provide superior performance compared to V2X systems based on consumer grade Wi Fi chipsets especially at high vehicle speeds and in non line of sight NLOS conditions The VERA P1 series includes an integrated MAC LLC Baseband processor and the required RF front end components The module is connected to a host processor throu...

Страница 6: ...d SPI1 host interfaces Frequency band 5 850 5 925 MHz channels 172 174 176 178 180 182 184 Channel bandwidth 10 MHz2 Data rates 3 4 5 6 9 12 18 24 27 Mbps Antenna diversity VERA P173 VERA P174 CDD for TX and MRC for RX mode TX output power from 0 to 23 dBm Class C RX sensitivity 98 dBm at 3 Mbps Power supply 3 3 V and 5 0 V 5 W Operation temperature 40 C to 95 C Dimensions 29 6 x 24 8 x 3 5 mm 1 S...

Страница 7: ...supports an SPI interface for firmware loading booting and data communication Firmware can be loaded by the host processor while the module operates as a slave or from the FLASH memory while the module is in the master mode The interface is capable of full duplex operation in master or slave mode The maximum clock rate is 50 MHz in master mode and 25 MHz in slave mode3 Due to performance limitatio...

Страница 8: ...VERA P1 series Data Sheet UBX 17004377 R06_draft Confidential Pin Definition Page 8 of 30 3 Pin Definition 3 1 Pin description Figure 2 Pin allocation top view ...

Страница 9: ...A13 NC Leave unconnected A14 NC Leave unconnected A15 NC Leave unconnected A16 NC Leave unconnected A17 NC Leave unconnected A18 GND Ground Ground A19 5V0_A1 Power Antenna 1 radio front end supply A20 GND Ground Ground A21 GPIO2_11 I O 1V8 GPIO2_11 A22 GPIO2_12 I O 1V8 GPIO2_12 A23 GND Ground Ground A24 GND Ground Ground A25 GND Ground Ground A26 ANT1 RF I O Antenna 1 A27 GND Ground Ground A28 GND...

Страница 10: ...d A55 NC Leave unconnected A56 NC Leave unconnected A57 GND Ground Ground A58 NC Leave unconnected A59 NC Leave unconnected A60 NC Leave unconnected A61 GND Ground Ground A62 USB_DN I O USB Bus A63 USB_DP I O USB Bus A64 USB_VBUS I USB VBUS detect input A65 GND Ground Ground A66 GND Ground Ground A67 GND Ground Ground A68 GPIO1_12 I O VIO UART1_RX A69 GND Ground Ground A70 1PPS I 1V8 One pulse per...

Страница 11: ...e unconnected B12 NC Leave unconnected B13 NC Leave unconnected B14 NC Leave unconnected B15 NC Leave unconnected B16 NC Leave unconnected B17 GND Ground Ground B18 5V0_A1 Power Antenna 1 radio front end supply B19 GND Ground Ground B20 GPIO2_13 I O 1V8 GPIO2_13 B21 GPIO2_14 I O 1V8 GPIO2_14 B22 GND Ground Ground B23 GND Ground Ground B24 GND Ground Ground B25 PA1_EN I O VIO PA enable for ANT1 B26...

Страница 12: ...round Ground B53 NC Leave unconnected B54 NC Leave unconnected B55 NC Leave unconnected B56 GND Ground Ground B57 NC Leave unconnected B58 NC Leave unconnected B59 NC Leave unconnected B60 NC Leave unconnected B61 GPIO1_11 I O VIO UART1_TX B62 NC Leave unconnected B63 GND Ground Ground B64 NC Leave unconnected B65 NC Leave unconnected B66 NC Leave unconnected B67 NC Leave unconnected B68 NC Leave ...

Страница 13: ...VERA P1 series Data Sheet UBX 17004377 R06_draft Confidential Pin Definition Page 13 of 30 Table 3 VERA P1 series pin description ...

Страница 14: ...aximum ratings Symbol Description Min Max Units 5V0_A1 5V0_A2 Power supply voltage 5 0 V 0 3 6 0 V 3V3 Power supply voltage 3 3 V 0 3 3 9 V VIO I O supply voltage 1 8 V 2 5 V 3 3 V 0 3 3 9 V TSTORAGE Storage temperature 40 95 ºC Table 4 Absolute maximum ratings The product is not protected against overvoltage or reversed voltages If necessary voltage spikes exceeding the power supply voltage speci...

Страница 15: ...na 5V0 peak current applies to each RX chain 461 0 55 30 TX single antenna 0 dBm 432 0 45 186 10 dBm 434 0 45 197 20 dBm 437 0 45 273 TX dual antenna output power and 5V0 peak current apply to each TX chain 0 dBm 563 0 55 186 10 dBm 565 0 55 197 20 dBm 570 0 55 273 Table 7 Peak current consumption typical values are referenced to TA 25 C 3V3 3 3 V VIO 1 8 V 5V0_A1 5V0_A2 5 0 V The average current ...

Страница 16: ...2 11p 20 dBm RSSI accuracy 802 11p Over temperature range 3 dB Center frequency and symbol clock tolerance 802 11p 10 ppm Transmitter spectral flatness 802 11p All modulation modes 2 dB Transmitter center frequency leakage 802 11p 15 dB Transmit power control step size 802 11p 0 5 dB Transmit power control accuracy 802 11p Over temperature range 2 dB Table 8 Radio specifications values are referen...

Страница 17: ...CR dB 3 Mbps 1 2BPSK 16 28 37 4 5 Mbps 3 4BPSK 15 27 33 6 Mbps 1 2QPSK 13 25 35 9 Mbps 3 4QPSK 11 23 29 12 Mbps 1 2QAM16 8 20 29 18 Mbps 3 4QAM16 4 16 25 24 Mbps 2 3QAM64 0 12 22 27 Mbps 3 4QAM64 1 11 20 Table 10 Adjacent channel rejection Bit rate Target ACR dB Target opt enc ACR dB VERA P1 typical ACR dB 3 Mbps 1 2BPSK 32 42 51 4 5 Mbps 3 4BPSK 31 41 48 6 Mbps 1 2QPSK 29 39 48 9 Mbps 3 4QPSK 27 ...

Страница 18: ...VERA P1 series Data Sheet UBX 17004377 R06_draft Mechanical specifications Page 18 of 30 Confidential 5 Mechanical specifications 5 1 Physical dimensions Figure 3 Physical dimensions ...

Страница 19: ...ion of the exposed thermal pads pattern 22 3 22 4 22 5 E3 Vertical dimension of the individual exposed thermal pad 3 9 4 0 4 1 e Pitch of the peripheral pads 1 2 BSC E1 Pitch of the individual exposed thermal pads 4 6 BSC aaa Bilateral profile tolerance of the module body 0 2 ddd Co planarity of the module bottom surface unilateral tolerance 0 1 eee Tolerance of the peripheral pads pattern positio...

Страница 20: ... must not be co located or operating in conjunction with any other antenna or transmitter These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instructions may cause harmful interference to radio co...

Страница 21: ...VERA P1 series Data Sheet UBX 17004377 R06_draft Qualification and approvals Page 21 of 30 Confidential ...

Страница 22: ...ut packaging see the u blox Package Information Guide 1 7 1 1 Reels The VERA P1 series modules are deliverable in quantities of 250 pieces on a reel The VERA P1 series modules are shipped on reel Type A as specified in the u blox Package Information Guide 1 7 1 2 Tapes Figure 4 shows the position and orientation of the VERA P1 modules as they are delivered on tape The dimensions of the tapes are s...

Страница 23: ... Use of No Clean soldering paste is strongly recommended cleaning the populated modules is strongly discouraged residuals under the module cannot be easily removed with any cleaning process Cleaning with water can lead to capillary effects where water is absorbed into the gap between the host board and module The combination of soldering flux residuals and encapsulated water could lead to short ci...

Страница 24: ...ever handling the receiver Unless there is a galvanic coupling between the local GND i e the work table and the PCB GND then the first point of contact when handling the PCB must always be between the local GND and PCB GND Before mounting an antenna patch connect ground of the device When handling the RF pin do not come into contact with any charged capacitors and be careful when contacting materi...

Страница 25: ...rdering information 8 1 Product labeling The labels of VERA P1 series include important product information as described in this section Figure 7 illustrates the sample label of the VERA P1 series A detailed description of the label components are listed in Table 16 Figure 7 VERA P1 series Sample label 8 1 4 5 6 7 3 2 11 9 10 ...

Страница 26: ...tion 8 2 Explanation of codes Three different product code formats are used The Product Name is used in documentation such as this data sheet and identifies all u blox products independent of packaging and quality grade The Ordering Code includes options and quality while the Type Number includes the hardware and firmware versions Table 17 below details these three different formats Format Structu...

Страница 27: ... VERA P173 00A 00 VERA P173 VERA P173 automotive grade module VERA P174 00A 00 VERA P174 VERA P174 automotive grade module EVK VERA P174 00A EVK VERA P174 Evaluation kit for VERA P173 and VERA P174 Table 19 Product ordering codes Product changes affecting form fit or function are documented by u blox For a list of Product Change Notifications PCNs see our website ...

Страница 28: ...ommission GND Ground GPIO General purpose input output IC Industry Canada LLC Logical Link Control MAC Media Access Control nACR Non adjacent channel rejection NLoS Non Line of Sight OBU On Board Unit OFDM Orthogonal frequency division multiplexing PCB Printed Circuit Board RF Radio Frequency RSU Road Side Unit RoHS Restriction of Hazardous Substances SPI Serial Peripheral Interface USB Universal ...

Страница 29: ... this variant R03 11 Sep 2017 mzes kgom ddie Updated Table 1 Included footnotes in section 1 5 Updated the ordering codes section 8 3 Added reel size section 7 1 and tape dimensions Figure 5 R04 17 Oct 2017 ddie kgom Removed references to VERA P175 variant Updated Table 1 R05 4 June 2018 smay kgom Updated total power consumption in section 1 5 Added SPI limitation in section 2 2 Added peak current...

Страница 30: ...om Regional Office China Beijing Phone 86 10 68 133 545 E mail info_cn u blox com Support support_cn u blox com Regional Office China Chongqing Phone 86 23 6815 1588 E mail info_cn u blox com Support support_cn u blox com Regional Office China Shanghai Phone 86 21 6090 4832 E mail info_cn u blox com Support support_cn u blox com Regional Office China Shenzhen Phone 86 755 8627 1083 E mail info_cn ...