MAX-M10M - Integration manual
•
Controlled software reset
terminates all running processes in an orderly manner. Once the
system is idle, restarts the receiver operation, reloads its configuration and starts to acquire
and track GNSS satellites.
•
Controlled software reset (GNSS only)
only restarts the GNSS tasks, without reinitializing the
full system or reloading any stored configuration.
•
Hardware reset (after shutdown)
uses the on-chip watchdog to reset the receiver after
shutdown.
•
Controlled GNSS stop
stops all GNSS tasks. The receiver will not be restarted, but will stop any
GNSS-related processing.
•
Controlled GNSS start
starts all GNSS tasks.
below contains an overview of the different reset types and the data that is cleared.
Reset type
Clears RAM
Clears BBR
0x00 - Hardware reset (immediately),
0x04 - Hardware reset (after shutdown)
Yes
Yes
0x01 - Controlled Software reset
Yes
No
0x02 - Controlled Software reset (GNSS only),
0x08 - Controlled GNSS stop,
0x09 - Controlled GNSS start
No
No
RESET_N pin
Yes
Yes
Table 20: Overview of the available reset types
2.6 Security
The security concept of MAX-M10M covers the air interface between the receiver and the GNSS
satellites and the integrity of the receiver itself.
There are functions to monitor/detect certain security threats and report it to the host system.
Other functions try to mitigate the threat and allow the receiver to operate normally.
2.6.1 Configuration locking
The receiver configuration can be locked so that further changes are no longer possible. The
configuration can be locked by setting the configuration item CFG-SEC-CFG_LOCK to "true". This
item can be set in the same way as all other configuration items on various layers.
If the configuration lock is set on any non-volatile layer (i.e., BBR), the operation is not
reversible and cannot be undone. To test the function, set it in the RAM configuration layer.
After the receiver's power cycle, the information in this layer is lost and the configuration
lock is not set anymore.
2.7 Power management
u-blox receivers support different operating modes. These modes represent strategies of controlling
the acquisition and tracking engines to achieve either the best possible performance or good
performance with reduced power consumption.
2.7.1 Continuous mode
MAX-M10M uses dedicated signal processing engines optimized for signal acquisition and tracking.
The acquisition engine actively searches for and acquires signals during cold starts or when
insufficient signals are available during navigation. The tracking engine continuously tracks and
UBX-22038241 - R01