background image

C101-D9S - User guide 

UBX-20031865 - R02 

Related documentation

  

Page 15 of 16 

C1-Public  

 

 

Related documentation 

[1]

 

NEO-D9S Integration manual, 

UBX-19026111

 

[2]

 

ZED-F9P Integration manual

UBX-18010802

 

[3]

 

u-center User guide, 

UBX-13005250

 

[4]

 

C099 application board User guide,

 UBX- 18063024

 

 

For product change notifications and regular updates of u-blox documentation, register on our 
website, 

www.u-blox.com

. 

 

Revision history 

Revision 

Date 

Name 

Comments 

R01 

30-Jul-2020 

dama 

Initial release 

R02 

24-June-2021  dama 

Add chapter 4: C101-D9S operation with C099-F9P 

 

Содержание C101-D9S

Страница 1: ...ic C101 D9S Application board rev C User guide Abstract This document explains the use of C101 D9S application board The C101 D9S board enables customers to evaluate L band GNSS correction services wi...

Страница 2: ...property rights in the products names logos and designs included in this document Copying reproduction modification or disclosure to third parties of this document or any part thereof is only permitt...

Страница 3: ...1 Package contents 4 2 C101 D9S product overview 5 2 1 Components 5 2 2 Jumpers 6 3 C101 D9S standalone operation 7 4 C101 D9S operation with C099 F9P 9 Appendix 11 A Glossary 11 B NEO D9S L band con...

Страница 4: ...rection services enables high precision navigation globally in multiple regions as well as coverage across continents The C101 D9S application board offers NEO D9S module for use as L band correction...

Страница 5: ...data receiver The board is powered from the USB cable connection or via Arduino shield The main components of the board are listed below and shown in Figure 1 and Figure 2 Native USB port FTDI USB br...

Страница 6: ...jumper provides 3 3 V power supply to an external active antenna plugged to the SMA RF connector The current limit circuit is also enabled up to 60 mA J8 This jumper switches the communication from t...

Страница 7: ...be installed automatically from Windows Update when the user connects the board for the first time The power LED will turn on in blue Start the Device Manager utility from Windows Two new ports will...

Страница 8: ...e the L band signal correction data See Appendix B for the default NEO D9S L band configuration which can be adapted for other services The messages UBX MON PMP and UBX RXM PMP see Figure 7 and Figure...

Страница 9: ...099 F9P board Figure 9 C101 D9S C099 F9P interfacing scheme Figure 10 shows the placement of the Arduino connectors on the C101 D9S board and Figure 11 shows how to physically connect the C099 F9P boa...

Страница 10: ...g on the position of jumper J8 on the C101 D9S board as shown below the ZED F9P housed on the C099 F9P board will receive the correction data on the UART1 or the UART2 port The ZED F9P receives the co...

Страница 11: ...rvice ID Service provider frequency based on geographical location Service provider data rate This means that the frequency allocation for a particular service provider could change Service providers...

Страница 12: ...ide UBX 20031865 R02 Appendix Page 12 of 16 C1 Public See the NEO D9S Integration manual 1 for further details D C101 D9S schematics The following pages show the complete schematics for the C101 D9S e...

Страница 13: ...C101 D9S User guide UBX 20031865 R02 Appendix Page 13 of 16 C1 Public...

Страница 14: ...C101 D9S User guide UBX 20031865 R02 Appendix Page 14 of 16 C1 Public...

Страница 15: ...anual UBX 18010802 3 u center User guide UBX 13005250 4 C099 application board User guide UBX 18063024 For product change notifications and regular updates of u blox documentation register on our webs...

Страница 16: ...nal Office China Beijing Phone 86 10 68 133 545 E mail info_cn u blox com Support support_cn u blox com Regional Office China Chongqing Phone 86 23 6815 1588 E mail info_cn u blox com Support support_...

Отзывы: