Ubisys C4 Скачать руководство пользователя страница 7

 1 

41          element type: 0x41 (raw data)

 2 

08 00       element count: 0x0008 (8 entries)

 3 
 4 

06          element #1: six bytes

 5 

00          InputAndOptions: 0x00

 6 

0D          Transition: released -> pressed

 7 

01          Source: Endpoint #1 (hosts primary on/off client cluster on C4)

 8 

06 00       Cluster ID: 0x0006 - on/off

 9 

02          ZCL Command Template: Toggle

10 
11 

06          element #2: six bytes

12 

00          InputAndOptions: 0x00

13 

03          Transition: any -> released

14 

01          Source: Endpoint #1 (hosts primary on/off client cluster on C4)

15 

06 00       Cluster ID: 0x0006 - on/off

16 

02          ZCL Command Template: Toggle

17 
18 

06          element #3: six bytes

19 

01          InputAndOptions: 0x01

20 

0D          Transition: released -> pressed

21 

02          Source: Endpoint #2 (hosts secondary on/off client cluster on C4)

22 

06 00       Cluster ID: 0x0006 - on/off

23 

02          ZCL Command Template: Toggle

24 
25 

06          element #4: six bytes

26 

01          InputAndOptions: 0x01

27 

03          Transition: any -> released

28 

02          Source: Endpoint #2 (hosts secondary on/off client cluster on C4)

29 

06 00       Cluster ID: 0x0006 - on/off

30 

02          ZCL Command Template: Toggle

31 
32 

06          element #5: six bytes

33 

02          InputAndOptions: 0x02

34 

0D          Transition: released -> pressed

35 

03          Source: Endpoint #3 (hosts tertiary on/off client cluster on C4)

36 

06 00       Cluster ID: 0x0006 - on/off

37 

02          ZCL Command Template: Toggle

38 
39 

06          element #6: six bytes

40 

02          InputAndOptions: 0x02

41 

03          Transition: any -> released

42 

03          Source: Endpoint #3 (hosts tertiary on/off client cluster on C4)

43 

06 00       Cluster ID: 0x0006 - on/off

44 

02          ZCL Command Template: Toggle

45 
46 

06          element #7: six bytes

47 

03          InputAndOptions: 0x03

48 

0D          Transition: released -> pressed

49 

04          Source: Endpoint #4 (hosts quaternary on/off client cluster on C4)

50 

06 00       Cluster ID: 0x0006 - on/off

51 

02          ZCL Command Template: Toggle

52 
53 

06          element #8: six bytes

54 

03          InputAndOptions: 0x03

55 

03          Transition: any -> released

56 

04          Source: Endpoint #4 (hosts quaternary on/off client cluster on C4)

57 

06 00       Cluster ID: 0x0006 - on/off

58 

02          ZCL Command Template: Toggle

5

Содержание C4

Страница 1: ...ZIGBEE DEVICE PHYSICAL INPUT CONFIGURATIONS INTEGRATOR S GUIDE...

Страница 2: ...off Switch 8 3 5 1 Example 8 3 5 2 Example 9 3 6 Single Momentary Switch Push Button as Dimmer Switch 10 3 6 1 Examples 10 3 7 Double Momentary Switch Push Buttons as Dimmer Switch 12 3 7 1 Examples...

Страница 3: ...standard the ZigBee Application Foundation including the ZigBee Cluster Library and related technologies and specifications The intended audience mainly comprises system integrators who want to take a...

Страница 4: ...put and the input configured to send on commands in one position and off commands the other position or toggle commands in each position Other options include momentary push button switches with toggl...

Страница 5: ...e move rates specific target levels time spans for automatically turning off to be embedded into the command templates It is also easily extensible Sending new commands or supporting new clusters does...

Страница 6: ...elated C class CZigBeeDeviceSetupInputPatternSwitchToggle This is similar to the push button version but intended for switches with two stable positions Sends a toggle command on every flip It is usef...

Страница 7: ...ource Endpoint 2 hosts secondary on off client cluster on C4 29 06 00 Cluster ID 0x0006 on off 30 02 ZCL Command Template Toggle 31 32 06 element 5 six bytes 33 02 InputAndOptions 0x02 34 0D Transitio...

Страница 8: ...e in such a scenario is that the lights are inherently synchronized to the same final state even if they initially had different states i e the lights will be all on or all off after flipping the swit...

Страница 9: ...2 Source Endpoint 2 hosts secondary on off client cluster on C4 29 06 00 Cluster ID 0x0006 on off 30 00 ZCL Command Template Off 31 32 06 element 5 six bytes 33 02 InputAndOptions 0x02 34 0D Transitio...

Страница 10: ...it is frequently triggered to either turn on or remain on and thus tolerates missing an off command for equipment that could potentially be damaged or cause damage when operated continuously The idea...

Страница 11: ...24 0B element 3 11 bytes 25 00 InputAndOptions 0x00 26 0D Transition released pressed 27 03 Source Endpoint 3 hosts primary on off client cluster on C4 28 06 00 Cluster ID 0x0006 on off 29 42 ZCL Comm...

Страница 12: ...generally speaking adjusting the level intensity speed brightness of a level controllable output Users are able to turn a light on or off with a short press i e tapping the button for less than a seco...

Страница 13: ...e Toggle 38 39 08 element 6 eight bytes 40 01 InputAndOptions 0x01 41 86 Transition pressed kept pressed has alternate 42 03 Source Endpoint 3 hosts secondary level control client cluster on D1 43 08...

Страница 14: ...witch will turn the lights off a long press on this button will dim the lights down The idea is that each transition from the pressed state to the released state fires an on command for the first butt...

Страница 15: ...sed 28 02 Source Endpoint 2 hosts primary on off client cluster on D1 29 06 00 Cluster ID 0x0006 on off 30 00 ZCL Command Template Turn off 31 32 08 element 5 eight bytes 33 01 InputAndOptions 0x01 34...

Страница 16: ...ID 0x0102 window covering 16 02 ZCL Command Template Stop 17 18 06 element 3 six bytes 19 01 InputAndOptions 0x01 20 0D Transition released pressed 21 02 Source Endpoint 2 hosts window covering client...

Страница 17: ...window covering 16 02 ZCL Command Template Stop 17 18 06 element 3 six bytes 19 01 InputAndOptions 0x01 20 0D Transition released pressed 21 02 Source Endpoint 2 hosts window covering client cluster...

Страница 18: ...pressed 7 01 Source Endpoint 1 hosts primary scene client cluster on C4 8 05 00 Cluster ID 0x0005 scenes 9 05 34 12 56 ZCL Command Template Recall scene group ID 0x1234 scene ID 0x56 10 11 06 element...

Страница 19: ...all other input actions a recall scene command will always be sent as groupcast to the group specified in the payload of the recall scene command The idea is that each transition from the pressed stat...

Страница 20: ...1 31 32 06 element 5 six bytes 33 02 InputAndOptions 0x02 34 07 Transition pressed released 35 03 Source Endpoint 3 hosts tertiary scene client cluster on C4 36 05 00 Cluster ID 0x0005 scenes 37 05 44...

Страница 21: ...e logical control unit endpoint or introduces a new endpoint with the new cluster to facilitate finding binding For the raw functionality it is not strictly required though 2 Qualified customers may l...

Страница 22: ...ommand Recall scene commands are now always sent to the group ID in the payload and don t require an entry in the binding table 0 9 11 25 2014 Preliminary version for internal use only 1 0 05 31 2017...

Страница 23: ...5 Contact ubisys technologies GmbH Neumannstr 10 40235 D sseldorf Germany T 49 211 54 21 55 19 F 49 211 54 21 55 99 www ubisys de info ubisys de 21...

Отзывы: