3. Connect the AC trunk cable (previously connected to the
Microinverter) to the Output port on the Solar Gateway.
4. Connect the Input cable from the Solar Gateway to the
four-prong connector on the Microinverter.
Страница 1: ...Solar Gateway Model SM SG...
Страница 2: ...Package Contents Solar Gateway Model SM SG Solar Gateway AC Disconnect Tool Unlock Tool Quick Start Guide Hardware Overview Ports Ethernet Port This Ethernet port is used to connect the Solar Gateway...
Страница 3: ...reen when the network and cloud are connected It will light red if a network connection cannot be established Inverter Activity The Inverter Activity LED will light steady green if all Microinverters...
Страница 4: ...nt shock or damage 1 Tilt the Solar Gateway forward and attach it to the AC Module by hooking it underneath the outer edge and rotating it down until it sits firmly against the panel AC Module Solar G...
Страница 5: ...nnect the AC trunk cable previously connected to the Microinverter to the Output port on the Solar Gateway 4 Connect the Input cable from the Solar Gateway to the four prong connector on the Microinve...
Страница 6: ...solar array 5 Download the sunMAX Install app from the App Store iOS or Google Play Android 6 Launch the sunMAX Install app and type your username and password into their corresponding fields Note Th...
Страница 7: ...9 When the Site Dashboard screen appears tap Gateway 10 When prompted for a connection type to your local network tap Ethernet...
Страница 8: ...Ethernet cable to your Solar Gateway by performing steps a c and tap Next when finished a Remove the Port Cover from the Solar Gateway and remove the Cable Feed Plug from the Port Cover Cable Feed Pl...
Страница 9: ...b Connect an Ethernet cable from your home network to the Ethernet Port on the Solar Gateway Ethernet Port c Replace the Port Cover...
Страница 10: ...12 Tap Scan QR to pair the Solar Gateway with the current customer site information 13 Scan the QR code to complete the pairing process...
Страница 11: ...14 The MAC address and serial number should appear Tap Next to continue or Redo Scan if necessary 15 The following screen appears while the Gateway is connecting to your network and being configured...
Страница 12: ...been set up and connected to your home network return to the Dashboard screen to verify the Gateway connection For more information or detailed instructions please refer to the sunMAX Solar Gateway Us...
Страница 13: ...Flash Networking Interface 1 10 100 1000 Mbps RJ45 Ethernet Port Bluetooth Low Power BLE Bluetooth v4 1 LEDs 3 LEDs Power Web Connectivity Inverter Connectivity Button Reset Button Max Power Consumpt...
Страница 14: ...te risk of electric shock from lightning Electrical Safety Information 1 Compliance is required with respect to voltage frequency and current requirements indicated on the manufacturer s label Connect...
Страница 15: ...V has been subjected to misuse abuse negligence abnormal physical electromagnetic or electrical stress including lightning strikes or accident V has been damaged or impaired as a result of using third...
Страница 16: ...FACILITIES UBIQUITI NETWORKS ITS AFFILIATES AND ITS AND THEIR THIRD PARTY PROVIDERS ARE NOT RESPONSIBLE FOR ANY INTERRUPTIONS DELAYS CANCELLATIONS DELIVERY FAILURES DATA LOSS CONTENT CORRUPTION PACKET...
Страница 17: ...dio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not o...
Страница 18: ...the device CAN ICES 3 B NMB 3 B Pour r duire le risque d interf rence aux autres utilisateurs le type d antenne et son gain doivent tre choisies de fa on que la puissance isotrope rayonn e quivalente...
Страница 19: ...ice or the shop where you purchased the product Deutsch Die Europ ische Richtlinie 2002 96 EC verlangt dass technische Ausr stung die direkt am Ger t und oder an der Verpackung mit diesem Symbol verse...
Страница 20: ...insi que tout autre mat riel lectrique ou lectronique par les moyens de collecte indiqu s par le gouvernement et les pouvoirs publics des collectivit s territoriales L limination et le recyclage en bo...
Страница 21: ...aisten vaatimusten ja muiden sit koskevien direktiivin 1999 5 EY Fran ais French Par la pr sente UBIQUITI NETWORKS d clare que l appareil UBIQUITI NETWORKS est conforme aux exigences essentielles et a...
Страница 22: ...ski Polish Niniejszym Ubiquiti Networks o wiadcza e urz dzenie UBIQUITI NETWORKS jest zgodny z zasadniczymi wymaganiami oraz pozosta ymi stosownymi postanowieniami Dyrektywy 1999 5 EC Portugu s Portug...
Страница 23: ...Online Resources Support support ubnt com Community community ubnt com Downloads downloads ubnt com...
Страница 24: ...quiti beam logo and sunMAX are trademarks or registered trademarks of Ubiquiti Networks Inc in the United States and in other countries Google Android Google Play and other marks are trademarks of Goo...