background image

State

Status

RJ-45 Speed/
Link/Activity 
LED (Ports 
1 - 9)

Off

No Link

Amber

Link Established at 10/100 Mbps
Flashing Indicates Activity

Green

Link Established at 1 Gbps
Flashing Indicates Activity

SFP+ Speed/
Link/Activity 
LED (Ports 
10 - 11)

Off

No Link

Green

Link Established at 1 Gbps
Flashing Indicates Activity

White

Link Established at 10 Gbps
Flashing Indicates Activity

Item

Description

HDD Bay

Install a 3.5" or 2.5" HDD (not included) to 
use the device as an NVR for UniFi Protect. 

RJ45 LAN 
(Ports 1 - 8)

The RJ45 ports support 10/100/1000 
Ethernet connections. By default, they are set 

to 

DHCP Server

 with the fallback IP address, 

192.168.1.1/24

RJ45 Internet 
(Port 9) 

The RJ45 port supports a 10/100/1000 
Ethernet connection. Set to 

DHCP Client

 by 

default.

SFP+ Internet 
(Port 10)

The SFP+ port supports a 1/10G Ethernet 
connection. Set to 

DHCP Client

 by default.

SFP+ LAN 
(Port 11) 

The SFP+ port supports a 1/10G Ethernet 
connection. By default, it is set to 

DHCP 

Server

 with the fallback IP address, 

192.168.1.1/24

Содержание Dream Machine Pro UDM-Pro

Страница 1: ...Enterprise Security Gateway and Network Appliance with 10G SFP Model UDM Pro ...

Страница 2: ...kets Qty 2 Bracket Screws Qty 8 Mounting Screws Qty 4 Cage Nuts Qty 4 Security Screw 2 5 HDD Screws Qty 4 Rubber Feet Qty 4 System Requirement Either of the following is required iOS or Android Mobile Device with UniFi App Installed Web Browser Google Chrome Other browsers may have limited functionality IMPORTANT We strongly recommend using UPS backup and power regulation to prevent equipment dama...

Страница 3: ...ing deinitializing Heartbeat Firmware update in process Blue Solid Device is configured and ready Slow Flashing Client connected to device via Bluetooth BLE Off White Blue Flashing Device is in recovery mode The LED will cycle through a pattern at one second intervals between off white and blue HDD LED Color State Status White Flashing Indicates Read Write Activity Amber Steady Indicates HDD Error...

Страница 4: ...nstall a 3 5 or 2 5 HDD not included to use the device as an NVR for UniFi Protect RJ45 LAN Ports 1 8 The RJ45 ports support 10 100 1000 Ethernet connections By default they are set to DHCP Server with the fallback IP address 192 168 1 1 24 RJ45 Internet Port 9 The RJ45 port supports a 10 100 1000 Ethernet connection Set to DHCP Client by default SFP Internet Port 10 The SFP port supports a 1 10G ...

Страница 5: ...Reset button for about 10 seconds until the LED starts flashing and then becomes solidly lit After a few seconds the LED will turn off and the device will automatically reboot 11 12 13 Item Description USP RPS LED Reserved for future use USP RPS Input Reserved for future use Power Connect the included Power Cord to the Power port ...

Страница 6: ...onnections and should be grounded through the AC ground of the power supply We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial grade shielded Ethernet cable from Ubiquiti For more details visit ui com toughcable Note Although the cabling can be located outdoors the UDM Pro itself should be housed inside a protective enclosure Be...

Страница 7: ...2 3 ...

Страница 8: ...4 ...

Страница 9: ...OR ...

Страница 10: ...5 ...

Страница 11: ...6 ...

Страница 12: ...Hardware Installation 1 2 OR ...

Страница 13: ......

Страница 14: ...Connecting Power ...

Страница 15: ...Connecting to the Internet For information about compatible fiber SFP modules visit ubnt link UniFi_SFP_DAC_Compatibility 1 OR ...

Страница 16: ...1000Mbps SM SC 20KM DDM Tx1550nm Rx1310n m 5 0 ...

Страница 17: ...Connecting to the LAN 1 5 0 2 5 0 ...

Страница 18: ...3 5 0 1000Mbp s SM SC 20KM DDM Tx1550nm Rx1310n m 4 5 0 5 0 ...

Страница 19: ...uration You have the following options Enable Bluetooth on your mobile device and use the UniFi Network app Use a computer connected to the UDM Pro on a LAN port Go to Chrome Instructions UniFi Network App 1 ...

Страница 20: ...2 1 5 m 1 5 m 3 Follow the on screen instructions ...

Страница 21: ...Setup Wizard After you run the UniFi Setup Wizard a login screen will appear for the UniFi Network Controller management interface Enter the Username and Password that you created in the UniFi Setup Wizard Then click Sign in You can manage your network and view network statistics using the UniFi Network Controller management interface For information on using the UniFi Network Controller software ...

Страница 22: ...Bluetooth BLE Max Power Consumption 33W Power Method 1 Universal AC Input 100 to 240VAC 1 RPS DC Input Power Supply Internal 50W 12V Supported Voltage Range 100 240VAC Display 1 3 Color Touch Panel LED System HDD RJ45 SFP Status Activity Link Speed Activity Link Speed Activity Processor Quad ARM Cortex A57 Core at 1 7 GHz System Memory 4 GB DDR4 On Board Flash Storage 16 GB eMMC Operating Temperat...

Страница 23: ... provided only by a qualified service technician 3 This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet a Do not substitute the power cord with one that is not the provided approved type Never use an adapter plug to connect to a 2 wire outlet as this will defeat the continuity of the grounding wire b Th...

Страница 24: ...eived including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio freq...

Страница 25: ...ctionnement Le présent émetteur radio IC 6545A UDMPRO a été approuvé par ISDE Canada IMPORTANT NOTE Radiation Exposure Statement This equipment complies with radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body This transmitter must not be co located or operating in conjunc...

Страница 26: ...untry List AT BE BG CY CZ DE DK EE EL ES FI FR HR HU IE IT LV LT LU MT NL PL PT RO SE SI SK UK BFWA Broadband Fixed Wireless Access members noted in blue Note This device meets Max TX power limit per ETSI regulations The following apply to products that operate in the 5 GHz frequency range Note This device is restricted to indoor use only when operating in the 5150 5350 MHz frequency range within ...

Страница 27: ...ce or the shop where you purchased the product Deutsch Die Europäische Richtlinie 2012 19 EU verlangt dass technische Ausrüstung die direkt am Gerät und oder an der Verpackung mit diesem Symbol versehen ist nicht zusammen mit unsortiertem Gemeindeabfall entsorgt werden darf Das Symbol weist darauf hin dass das Produkt von regulärem Haushaltmüll getrennt entsorgt werden sollte Es liegt in Ihrer Ver...

Отзывы: