background image

9

Chapter 2: Installation

airFiber

®

 AF-5X User Guide

 Ubiquiti Networks, Inc.

Surge Protection

For added protection, install two surge suppressors, such 
as the Ubiquiti Ethernet Surge Protector, model ETH-SP, 
at the end of each link. Install the first surge protector 
within one meter of the airFiber DATA port, and install the 
second surge protector at the ingress point of the location 
housing the wired network equipment.

Ground to Pole, Tower,

or Grounding Block:

Max. 1 m from AF-5X

M

ax. 1 m

airFiber

PoE Adapter

EdgeRouter

Power Source

ETH-SP

GPS Antenna

ETH-SP

AF-5X

Mounted on

AF-5G30-S45

Alignment

Tips

•  To accurately align the airFiber radios for best 

performance, you MUST align only one end of the link at 
a time.

•  You may need to use additional hardware to 

compensate for issues such as the improper orientation 
of a mounting pole or significant elevation differences 
between airFiber radios.

Establishing a Link

Adjust the positions of the Master and the Slave to 
establish a link. The following guide features the airFiber 
antenna, AF-5G30-S45:

Note:

 The Master must be aimed first at the Slave 

because the Slave does not transmit any RF signal 
until it detects transmissions from the Master.

1. 

Master

  Visually aim the Master at the Slave. To adjust 

the Master’s position:

a.  Loosen the four pole clamp nuts, and rotate the 

airFiber antenna on the pole to align the azimuth.

b.  Loosen the six elevation bolts, and use the hex nut on 

the elevation rod to adjust the elevation.

Note:

 Do NOT make simultaneous adjustments on 

the Master and Slave.

2. 

Slave

  Visually aim the Slave at the Master. To adjust the 

Slave’s position:

a.  Loosen the four pole clamp nuts, and rotate the 

airFiber antenna on the pole to align the azimuth.

b.  Loosen the six elevation bolts, and use the hex nut on 

the elevation rod to adjust the elevation.

www.4Gon.co.uk  [email protected]   Tel: +44 (0)1245 808295   Fax: +44 (0)1245 808299

Содержание airFiber 5X AF-5X

Страница 1: ...DATA MGMT GPS LINK DATA MGMT GPS LINK 5 GHz Carrier Backhaul Radio Model AF 5X www 4Gon co uk info 4gon co uk Tel 44 0 1245 808295 Fax 44 0 1245 808299...

Страница 2: ...Alignment 9 Installer Compliance Responsibility 10 Chapter 3 Navigation 11 Accessing the airFiber Configuration Interface 11 Product Verification 12 Interface Tabs 12 Chapter 4 Main Tab 13 Status 13...

Страница 3: ...29 Chapter 10 Tools 30 Align Antenna 30 Discovery 31 Ping 31 Traceroute 31 airView 31 Appendix A Specifications 35 Appendix B Safety Notices 36 Electrical Safety Information 36 Appendix C Warranty 37...

Страница 4: ...F 5X User Guide Ubiquiti Networks Inc Appendix E Declaration of Conformity 45 Appendix F Contact Information 46 Ubiquiti Networks Support 46 www 4Gon co uk info 4gon co uk Tel 44 0 1245 808295 Fax 44...

Страница 5: ...Radio Model AF 5X DATA MGMT GPS LINK DATA MGMT GPS LINK Cable Ties Qty 2 airFiber PoE Adapter with Mounting Bracket 24V 1A Power Cord Quick Start Guide TERMS OF USE Ubiquiti radio devices must be pro...

Страница 6: ...Hz flash This continues until the AF 5X is fully booted Signal Level Once fully booted the Signal 1 4 LEDs act as a bar graph showing how close the AF 5X is to ideal aiming This is auto scaled based...

Страница 7: ...odes Outdoor shielded Category 6 or above cabling and shielded RJ 45 connectors are required for all wired Ethernet connections Installation Overview We recommend that you configure your paired airFib...

Страница 8: ...ct your Country and Language You must agree to the Terms of Use to use the product Click Login Note U S product versions are locked to the U S Country Code to ensure compliance with FCC regulations 5...

Страница 9: ...lt DHCP to use DHCP reservation on your router to assign a unique IP Address Static Change the IP Address Netmask and other settings to make them compatible with your network b Click Change and then c...

Страница 10: ...lace 2 Attach the RF cables from the antenna feed to the RF connectors on the AF 5X in this combination 45 to Chain 0 and 45 to Chain 1 3 Attach the External GPS Antenna to the RF connector labeled GP...

Страница 11: ...e mount 3 Secure the cable of the External GPS Antenna to the mount with a Cable Tie Connecting Power over Ethernet 1 Lift the release latch on the bottom of the AF 5X and slide the Port Cover off 2 C...

Страница 12: ...r source Mount the PoE Adapter Optional 1 Remove the Mounting Bracket from the adapter by sliding the bracket downward 2 Place the Mounting Bracket at the desired location and mark the holes for the f...

Страница 13: ...ant elevation differences between airFiber radios Establishing a Link Adjust the positions of the Master and the Slave to establish a link The following guide features the airFiber antenna AF 5G30 S45...

Страница 14: ...the nuts and bolts 8 Observe the Signal LEDs of each airFiber radio to ensure that the values remain constant while tightening the nuts and bolts If any LED value changes during the locking process l...

Страница 15: ...details Accessing the airFiber Configuration Interface Connect to the airFiber Configuration Interface 1 Make sure that your host machine is connected to the LAN that is connected to the Management p...

Страница 16: ...nitoring links Wireless The Wireless Tab on page 16 configures basic wireless settings including the wireless mode link name frequency output power speed and wireless security Network The Network Tab...

Страница 17: ...ery tools Operating Mode Displays the mode of the AF 5X Slave Master or Reset RF Link Status Displays the status of the AF 5X RF Off Syncing Beaconing Registering Enabling Listening Operational DFS CA...

Страница 18: ...clock and the date and time may be inaccurate if the NTP Client is disabled or the device isn t connected to the Internet Frequency Displays the current frequency The AF 5X uses the radio frequency s...

Страница 19: ...this field displays normal DATA Pair 2 Pins 4 5 If the cable is functioning properly displays the SNR of the twisted pair if the cable has a fault displays the fault open or short and the distance at...

Страница 20: ...aster and the other as the Slave Basic Wireless Settings In this section configure the basic wireless settings such as wireless mode link name country code frequencies output power speed and gain Wire...

Страница 21: ...of maximum output power values by country and region refer to Frequency Ranges and Power Levels per Country Region on page 41 Antenna Gain Enter the gain in dBi of the antenna that is used in your ins...

Страница 22: ...s 0 9 A Z or a z Key Select the format of the MAC address HEX Enter 16 bytes eight 16 bit HEX values You can omit zeroes and use colons similar to the IPv6 format The default is 0000 0000 0000 0000 00...

Страница 23: ...ough the local Data port or the Data port at the other end of the link Note If In Band Management is enabled ensure that each airFiber radio of a link has a unique IP Address If the airFiber radios us...

Страница 24: ...ement VLAN If enabled automatically creates a management Virtual Local Area Network VLAN VLAN ID Enter a unique VLAN ID from 2 to 4094 Auto IP Aliasing If enabled automatically generates an IP address...

Страница 25: ...nd duplex mode select one of the following options 100 Mbps Full 100 Mbps Half 10 Mbps Full or 10 Mbps Half Full duplex mode allows communication in both directions simultaneously Half duplex mode all...

Страница 26: ...link to go down for a second time if the RF link goes down again Enter the minimum interval in seconds between offline events of the Ethernet link regardless of the RF link status The value for Link O...

Страница 27: ...e the fastest transmission mode they both support To manually specify the maximum transmission link speed and duplex mode select one of the following options 100 Mbps Full 100 Mbps Half 10 Mbps Full o...

Страница 28: ...ancel your changes click Discard Ping Watchdog Ping Watchdog sets the AF 5X to continuously ping a user defined IP address it can be the Internet gateway for example If it is unable to ping under the...

Страница 29: ...required to authenticate access to Management Information Base MIB objects and functions as an embedded password The AF 5X also supports a read only community string authorized management stations ha...

Страница 30: ...allows communications with the DDNS server Host Name Enter the host name of the DDNS server Username Enter the user name of the DDNS account Password Enter the password of the DDNS account Show Check...

Страница 31: ...he AF 5X times out and resumes its earlier configuration Discard To cancel your changes click Discard Firmware Update The controls in this section manage firmware maintenance Firmware Version Displays...

Страница 32: ...e following format 2 digit month 2 digit day 4 digit year For example for January 5 2014 enter 01 05 2014 in the field System Accounts You can change the administrator password to protect your device...

Страница 33: ...uration Management The controls in this section manage the AF 5X configuration routines and the option to reset the AF 5X to factory default settings The AF 5X configuration is stored in a plain text...

Страница 34: ...vel in dBm of the received signal for each chain Note If Overload is displayed to indicate an overload condition identify and eliminate any sources of strong in band interference Remote Chain 0 1 Sign...

Страница 35: ...on to start the test Packet loss statistics and latency time evaluation are displayed after the test is completed Traceroute The Traceroute tool traces the hops from the AF 5X to a specified outgoing...

Страница 36: ...aph shows the aggregate energy collected or channel usage for each frequency since the start of the airView session Enable Chart Panel 2 middle Displays the Waveform chart in Chart Panel 2 This time b...

Страница 37: ...e determined by IEEE standards AF 5X channels are numbered consecutively starting with 0 and are 28 MHz in width Enable Waveform chart middle Check the box to enable the middle chart This time based g...

Страница 38: ...d the maximum power trace is represented by the blue area on the Real time chart which displays the maximum received power level data since the start of the airView session To enable a shaded blue are...

Страница 39: ...ocket Mount Compatible GPS Pole Mount Included Certifications FCC Part 15 407 CE EN 302502 v1 2 1 EN 301 893 v1 7 1 Operating Temperature 40 to 55 C 40 to 131 F Networking Interface Data Port 1 10 100...

Страница 40: ...ld be provided only by a qualified service technician 3 This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety ou...

Страница 41: ...ires Returns No Products will be accepted for replacement or repair without obtaining a Return Materials Authorization RMA number from UBIQUITI NETWORKS during the warranty period and the Products bei...

Страница 42: ...implied warranties or conditions so the above exclusion may not apply to you You may have other rights that vary from country to country state to state or province to province Some countries states a...

Страница 43: ...B NMB 3 B To reduce potential radio interference to other users the antenna type and its gain should be so chosen that the equivalent isotropically radiated power e i r p is not more than that permit...

Страница 44: ...antenna or transmitter Les antennes utilis es pour ce transmetteur doivent tre install en consid rant une distance de s paration de toute personnes d au moins 126 cm et ne doivent pas tre localis ou...

Страница 45: ...150 5250 49 5470 5725 30 5725 5850 36 Australia 5470 5600 5650 5725 30 5725 5855 36 Bahrain 5735 5835 20 Barbados 5725 5850 36 Belize 5735 5835 30 Bolivia 5735 5835 30 Brazil 5470 5725 30 5725 5850 30...

Страница 46: ...30 Peru 5150 5250 49 5250 5350 30 5470 5725 30 5725 5850 36 Philippines 5150 5250 49 5250 5350 30 5470 5725 30 5725 5850 36 Portugal 5470 5725 30 5725 5875 36 Puerto Rico U S territory 5250 5350 30 5...

Страница 47: ...hannel Bandwidth Frequency Range Band Edges in MHz 10 MHz 5155 5175 39 5166 5186 44 5177 5250 49 20 MHz 5156 5180 37 5161 5185 39 5166 5209 44 5190 5250 49 30 MHz 5155 5192 39 5163 5202 44 5173 5211 3...

Страница 48: ...s de los puntos de recogida que ponen a su disposici n el gobierno y las autoridades locales Al desechar y reciclar correctamente estos aparatos estar contribuyendo a evitar posibles consecuencias ne...

Страница 49: ...lv egy b el r sainak slenska Icelandic H r me l sir UBIQUITI NETWORKS yfir v a UBIQUITI NETWORKS device er samr mi vi grunnkr fur og a rar kr fur sem ger ar eru tilskipun 1999 5 EC Italiano Italian Co...

Страница 50: ...riod Online Resources Support support ubnt com Community community ubnt com Downloads downloads ubnt com 2580 Orchard Parkway San Jose CA 95131 www ubnt com 2015 Ubiquiti Networks Inc All rights reser...

Отзывы: